Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 340

The DOI matches its Crossref record; 197 of the 197 references it cites were found in a registry or an index.

Advanced imaging for detection and differentiation of colorectal neoplasia: European Society of Gastrointestinal Endoscopy (ESGE) Guideline – Update 2019

Open access
Bisschops, Raf, East, James E., Hassan, Cesare, Hazewinkel, Yark, Kamiński, Michał F., Neumann, Helmut, Pellisé, Maria, Antonelli, Giulio, Bustamante Balen, Marco, Coron, Emmanuel, Cortas, Georges, Iacucci, Marietta, Yuichi, Mori, Longcroft-Wheaton, Gaius, Mouzyka, Serguei, Pilonis, Nastazja, Puig, Ignasi, van Hooft, Jeanin E., Dekker, Evelien·2019·Endoscopy

Abstract

Main Recommendations: 1 ESGE suggests that high definition endoscopy, and dye or virtual chromoendoscopy, as well as add-on devices, can be used in average risk patients to increase the endoscopist’s adenoma detection rate. However, their routine use must be balanced against costs and practical considerations. Weak recommendation, high quality evidence. 2 ESGE recommends the routine use of high definition systems in individuals with Lynch syndrome. Strong recommendation, high quality evidence. 3 ESGE recommends the routine use, with targeted biopsies, of dye-based pancolonic chromoendoscopy or virtual chromoendoscopy for neoplasia surveillance in patients with long-standing colitis. Strong recommendation, moderate quality evidence. 4 ESGE suggests that virtual chromoendoscopy and dye-based chromoendoscopy can be used, under strictly controlled conditions, for real-time optical diagnosis of diminutive (≤ 5 mm) colorectal polyps and can replace histopathological diagnosis. The optical diagnosis has to be reported using validated scales, must be adequately photodocumented, and can be performed only by experienced endoscopists who are adequately trained, as defined in the ESGE curriculum, and audited. Weak recommendation, high quality evidence. 5 ESGE recommends the use of high definition white-light endoscopy in combination with (virtual) chromoendoscopy to predict the presence and depth of any submucosal invasion in nonpedunculated colorectal polyps prior to any treatment. Strong recommendation, moderate quality evidence. 6 ESGE recommends the use of virtual or dye-based chromoendoscopy in addition to white-light endoscopy for the detection of residual neoplasia at a piecemeal polypectomy scar site. Strong recommendation, moderate quality evidence. 7 ESGE suggests the possible incorporation of computer-aided diagnosis (detection and characterization of lesions) to colonoscopy, if acceptable and reproducible accuracy for colorectal neoplasia is demonstrated in high quality multicenter in vivo clinical studies. Possible significant risks with implementation, specifically endoscopist deskilling and over-reliance on artificial intelligence, unrepresentative training datasets, and hacking, need to be considered. Weak recommendation, low quality evidence.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1055/a-1031-7657

Cites

197 of 197 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 197 references

Cited by

See all 340

Metadata

Authors
Bisschops, R., East, J. E., Hassan, C., Hazewinkel, Y., Kamiński, M. F., Neumann, H., Pellisé, M., Antonelli, G., Bustamante Balen, M., Coron, E., Cortas, G., Iacucci, M., Yuichi, M., Longcroft-Wheaton, G., Mouzyka, S., Pilonis, N., Puig, I., van Hooft, J. E., & Dekker, E.
Venue
Endoscopy
Published
2019-11-11
Volume
51
Issue
12
Pages
1155-1179
ISSN
  • 0013-726X (ISSN-L)
  • 1438-8812
OpenAlex
W4230531790
Cited by
340
References
197
FWCI
15.78
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Advanced imaging for detection and differentiation of colorectal neoplasia: European Society of Gastrointestinal Endoscopy (ESGE) Guideline – Update 2019. https://app.cochat.ai/papers/10.1055/a-1031-7657
The paper
Bisschops, R., East, J. E., Hassan, C., Hazewinkel, Y., Kamiński, M. F., Neumann, H., Pellisé, M., Antonelli, G., Bustamante Balen, M., Coron, E., Cortas, G., Iacucci, M., Yuichi, M., Longcroft-Wheaton, G., Mouzyka, S., Pilonis, N., Puig, I., van Hooft, J. E., & Dekker, E. (2019). Advanced imaging for detection and differentiation of colorectal neoplasia: European Society of Gastrointestinal Endoscopy (ESGE) Guideline – Update 2019. Endoscopy. https://doi.org/10.1055/a-1031-7657

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.