Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 237

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Development of a computer-aided detection system for colonoscopy and a publicly accessible large colonoscopy video database (with video)

Misawa, Masashi, Kudo, Shin-ei, Mori, Yuichi, Hotta, Kinichi, Ohtsuka, Kazuo, Matsuda, Takahisa, Saito, Shoichi, Kudo, Toyoki, Baba, Toshiyuki, Ishida, Fumio, Itoh, Hayato, Oda, Masahiro, Mori, Kensaku · 2021 · Gastrointestinal Endoscopy

Abstract

BACKGROUND AND AIMS Artificial intelligence (AI)-assisted polyp detection systems for colonoscopic use are currently attracting attention because they may reduce the possibility of adenomas being missed. However, few systems have the necessary regulatory approval for use in clinical practice. We aimed to develop an AI-assisted polyp detection system and to validate its performance using a large colonoscopy video database designed to be publicly accessible. METHODS To develop the deep learning-based AI system, 56,668 independent colonoscopy images were obtained from 5 centers for use as training images. To validate the trained AI system, consecutive colonoscopy videos taken at a university hospital between October 2018 and January 2019 were searched to construct a database containing polyps with unbiased variance. All images were annotated by endoscopists according to the presence or absence of polyps and the polyps' locations with bounding boxes. RESULTS A total of 1405 videos acquired during the study period were identified for the validation database, 797 of which contained at least one polyp. Of these, 100 videos containing 100 independent polyps and 13 videos negative for polyps were randomly extracted, resulting in a total of 152,560 frames (49,799 positive frames and 102,761 negative frames) for the database. The AI showed 90.5% sensitivity and 93.7% specificity for frame-based analysis. The per-polyp sensitivities for all, diminutive, protruded, and flat polyps were 98.0%, 98.3%, 98.5%, and 97.0%, respectively. CONCLUSIONS Our trained AI system was validated with a new large publicly accessible colonoscopy database and could identify colorectal lesions with high sensitivity and specificity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.gie.2020.07.060

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 237

Metadata

Authors
Misawa, M., Kudo, S.-E., Mori, Y., Hotta, K., Ohtsuka, K., Matsuda, T., Saito, S., Kudo, T., Baba, T., Ishida, F., Itoh, H., Oda, M., & Mori, K.
Venue
Gastrointestinal Endoscopy
Publisher
Elsevier BV
Published
2021-04
Volume
93
Issue
4
Pages
960-967.e3
ISSN
0016-5107 (ISSN-L)
OpenAlex
W3046240927
Cited by
237
References
8
FWCI
9.46
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Development of a computer-aided detection system for colonoscopy and a publicly accessible large colonoscopy video database (with video). https://app.cochat.ai/papers/10.1016/j.gie.2020.07.060
The paper
Misawa, M., Kudo, S.-E., Mori, Y., Hotta, K., Ohtsuka, K., Matsuda, T., Saito, S., Kudo, T., Baba, T., Ishida, F., Itoh, H., Oda, M., & Mori, K. (2021). Development of a computer-aided detection system for colonoscopy and a publicly accessible large colonoscopy video database (with video). Gastrointestinal Endoscopy. https://doi.org/10.1016/j.gie.2020.07.060

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.