Application of fused deposition modeling (FDM) on bone scaffold manufacturing process: A review
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Some of the health issues that are becoming more prevalent each year include bone disease and fractures. Because the natural healing process of bones takes a long time, a bone grafting procedure is required so that the patient's condition can improve rapidly. Because bone grafting procedures such as autographs, allographs, and xenografts have limits, bone replacement is constructed by employing biomaterials in the form of a bone scaffold via additive manufacturing. As a result, fused deposition modeling (FDM) is a proposed technology for the manufacturing process because it is straightforward, capable of producing complex parts and adjustable shapes, and has minimal operational expenses. However, implementing this technique is challenging because of the scarcity of biocompatible and bioactive materials that are suited. This technology has a number of limitations, including a limited variety of biocompatible and bioactive materials, the most appropriate microarchitecture of bone scaffold, and the establishment of printing parameters that can produce bone scaffold with the strongest mechanical properties. This article discusses current advancements in the use of FDM technologies for bone scaffold production.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Overview of Polylactides as Packaging Materials
Auras, R., Harte, B., & Selke, S. (2004) · Macromolecular Bioscience · doi:10.1002/mabi.200400043 · Cited by 3,454
Giannoudis, P. V., Dinopoulos, H., & Tsiridis, E. (2005) · Injury · doi:10.1016/j.injury.2005.07.029 · Cited by 2,078
Polylactide (PLA)-based nanocomposites
Raquez, J.-M., Habibi, Y., Murariu, M., & Dubois, P. (2013) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2013.05.014 · Cited by 1,209 · cited 1×
“Furthermore, PLA’s low biodegradability and hydrophobicity continue to limit its usage in the biomedical area [69].”
BackgroundBiomaterials for tissue engineered bone Scaffolds: A review
Kalsi, S., Singh, J., Sehgal, S. S., & Sharma, N. K. (2023) · Materials Today: Proceedings · doi:10.1016/j.matpr.2021.04.273 · Cited by 47 · cited 2×
“[11] classified biomaterials as natural polymers such as collagen, chitosan, silk fibroin, alginate, hyaluronic acid, and peptide hydrogels, and synthetic polymers such as polyesters and copolymers.”
Background
Metadata
- Authors
- Winarso, R., Anggoro, P. W., Ismail, R., Jamari, J., & Bayuseno, A. P.
- Venue
- Heliyon
- Publisher
- Elsevier BV
- Published
- 2022-11
- Volume
- 8
- Issue
- 11
- Pages
- e11701
- ISSN
- 2405-8440 (ISSN-L)
- OpenAlex
- W4309769113
- Cited by
- 163
- References
- 4
- FWCI
- 8.30
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Application of fused deposition modeling (FDM) on bone scaffold manufacturing process: A review. https://app.cochat.ai/papers/10.1016/j.heliyon.2022.e11701
- The paper
- Winarso, R., Anggoro, P. W., Ismail, R., Jamari, J., & Bayuseno, A. P. (2022). Application of fused deposition modeling (FDM) on bone scaffold manufacturing process: A review. Heliyon. https://doi.org/10.1016/j.heliyon.2022.e11701
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.