Effect of an automated dispensing cabinet system on drug distribution effectiveness in a surgical unit
Open accessAbstract
The use of the automated dispensing cabinet (ADC) for drug distribution in hospitals has become increasingly common and has numerous benefits. This retrospective study assessed the effectiveness of an ADC that uses integrated information technology in the drug distribution process in a surgical unit as part of a smart medical process improvement project at Taichung Veterans General Hospital in 2019. The outcomes include medicine delivery time, working time of healthcare professionals, transportation manpower, dispensing errors, and satisfaction of nursing staff with the medication distribution process. After ADC implementation, the average waiting time of standing orders decreased significantly for both on and off duty periods (40.0 ± 27.6 to 3.0 ± 3.9 min, P < 0.001; 45.2 ± 25.8 to 2.9 ± 2.9 min, P < 0.001; respectively). Similar results were observed with immediate or temporary medication orders (54.4 ± 31.5 to 2.0 ± 3.0 min, P < 0.001; 64.0 ± 47.5 to 1.5 ± 1.8 min, P < 0.001; respectively). The average time spent by operation room and post-operation room (OR/POR) nurses on communicating with ward nurses for medication delivery to OR/POR was shortened by 46.9 ± 4.4 h per month, and the average time pharmacists spent on dispensing immediate or temporary medication orders was shortened by 5.6 ± 0.2 h per month. The satisfaction of nursing staff with the OR/POR drug delivery process was significantly improved after ADC implementation (3.2 ± 0.8 vs 4.2 ± 0.7, P < 0.001). Our results showed that ADC implementation in surgical units simplified drug delivery processes, shortened drug delivery time, improved drug delivery timeliness for surgical patients, decreased dispensing errors, and increased nursing staff satisfaction. In conclusion, the implementation of ADC was beneficial for surgical units. To the best of our knowledge, there have been no studies on a similar ADC system.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Liou et al. noted that pharmacists spent on average 5.6 ± 0.2 h less per month dealing with requests for medication supply.
“Liou et al. noted that pharmacists spent on average 5.6 ± 0.2 h less per month dealing with requests for medication supply.35”
From Benefits and challenges associated with implementation and ongoing use of automated dispensing cabinet for medicines: A scoping review (2025) · cites this paper as [35]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
No references could be resolved yet.
Research works printed but not linked: 17
- [1]Pedersen C.A. Schneider P.J. Ganio M.C. Scheckelhoff D.J. ASHP national survey of pharmacy practice in hospital settings: dispensing and administration-2020 Am. J. Health Syst. Pharm. 78 12 2021 1074 1093 10.1093/ajhp/zxab120 PMC8083667 33754638 · DOI
- [2]Chapuis C. Bedouch P. Detavernier M. Automated drug dispensing systems in the intensive care unit: a financial analysis Crit. Care 19 1 2015 318 10.1186/s13054-015-1041-3 PMC4563942 26349855 · DOI · Paper page
- [3]Schwarz H.O. Brodowy B.A. Implementation and evaluation of an automated dispensing system Am. J. Health Syst. Pharm. 52 8 1995 823 828 10.1093/ajhp/52.8.823 7634117 · DOI
- [4]Borel J.M. Rascati K.L. Effect of an automated, nursing unit-based drug-dispensing device on medication errors Am. J. Health Syst. Pharm. 52 17 1995 1875 1879 10.1093/ajhp/52.17.1875 8528848 · DOI
- [5]Shirley K.L. Effect of an automated dispensing system on medication administration tim Am. J. Health Syst. Pharm. 56 15 1999 1542 1545 10.1093/ajhp/56.15.1542 10478994 · DOI
- [6]Wang Y.C. Tsan C.Y. Chen M.C. Implementation of an automated dispensing cabinet system and its impact on drug administration: longitudinal study JMIR Form Res 5 9 2021 e24542 10.2196/24542 PMC8486989 34533467 · DOI · Paper page
- [7]Tu H.N. Shan T.H. Wu Y.C. Shen P.H. Wu T.Y. Lin W.L. Yang-Kao Y.H. Cheng C.L. Reducing medication errors by adopting automatic dispensing cabinets in critical care units J. Med. Syst. 47 1 2023 52 10.1007/s10916-023-01953-0 PMC10136387 37103718 · DOI
- [8]Kheniene F. Bedouch P. Durand M. Economic impact of an automated dispensing system in an intensive care unit Ann. Fr. Anesth. Reanim. 27 3 2008 208 215 10.1016/j.annfar.2007.11.026 [In French, English abstract] 18272320 · DOI
- [9]McCarthy B.C. Jr. Ferker M. Implementation and optimization of automated dispensing cabinet technology Am. J. Health Syst. Pharm. 73 19 2016 1531 1536 10.2146/ajhp150531 27646814 · DOI · Paper page
- [10]Chapuis C. Roustit M. Bal G. Automated drug dispensing system reduces medication errors in an intensive care setting Crit. Care Med. 38 12 2010 2275 2278 10.1097/CCM.0b013e3181f8569b 20838333 · DOI
- [12]Mazzocato P. Savage C. Brommels M. Aronsson H. Thor J. Lean thinking in healthcare: a realist review of the literature Qual Saf Health Care. Oct 19 5 2010 376 382 10.1136/qshc.2009.037986 20724397 · DOI
- [13]Bickham P. Golembiewski J. Meyer T. Murray C.G. Wagner D. ASHP guidelines on perioperative pharmacy services Am. J. Health Syst. Pharm. 76 12 2019 10.1093/ajhp/zxz073 903-820 31361851 · DOI
- [14]Miller K. Shah M. Hitchcock L. Perry A. Englebright J. Perlin J. Burgess H. Evaluation of medications removed from automated dispensing machines using the override function leading to multiple system changes Henriksen K. Battles J.B. Keyes M.A. Grady M.L. Advances in Patient Safety: New Directions and Alternative Approaches Technology and Medication Safety) vol. 4 Aug. 2008 Agency for Healthcare Research and Quality (US) Rockville (MD) https://www.ncbi.nlm.nih.gov/books/NBK43777/ 21249969
- [15]Kowiatek J.G. Weber R.J. Skledar S.J. Frank S. DeVita M. Assessing and monitoring override medications in automated dispensing devices Joint Comm. J. Qual. Patient Saf. 32 6 2006 309 317 10.1016/s1553-7250(06)32040-5 16776385 · DOI
- [16]ASHP Guidelines on the safe use of automated dispensing devices Am. J. Health Syst. Pharm. 67 6 2010 483 490 10.2146/sp100004 20208056 · DOI
- [17]Metsämuuronen R. Kokki H. Naaranlahti T. Kurttila M. Heikkilä R. Nurses' perceptions of automated dispensing cabinets - an observational study and an online survey BMC Nurs. 19 2020 27 10.1186/s12912-020-00420-2 PMC7168878 32327934 · DOI · Paper page
- [18]Zaidan M. Rustom F. Kassem N. Al Yafei S. Peters L. Ibrahim M.I. Nurses' perceptions of and satisfaction with the use of automated dispensing cabinets at the Heart and Cancer Centers in Qatar: a cross-sectional study BMC Nurs. 15 2016 4 10.1186/s12912-015-0121-7 PMC4712505 26770071 · DOI
Cited by
Sorted by citations
Jung, Y. Y., Walsh, Á., Patel, J., & Lai, K. (2025) · Exploratory Research in Clinical and Social Pharmacy · doi:10.1016/j.rcsop.2025.100599 · Cited by 7 · see citing works
“19 This observation was supported by other publications, 15,19,20,23,35,39 where Cottney et al. described 66 min of time saving associated with medicines administration per ward per day by nurses (2.94 min pre-ADC to 2.37 min post-ADC).”
Influential
- Authors
- Liou, J.-H., Wang, S.-C., Hou, Y.-C., Yen, C.-H., Chen, H.-M., Liou, W.-S., & Wu, M.-F.
- Affiliations
- China Medical University (TW)
- Taichung Veterans General Hospital (TW)
- Corresponding author
- Wu, Ming-Fen
- Venue
- Heliyon
- Publisher
- Elsevier BV
- Published
- 2023-11
- Volume
- 9
- Issue
- 11
- Pages
- e21668
- ISSN
- 2405-8440 (ISSN-L)
- PMC
- PMC10660017
- OpenAlex
- W4388192738
- Cited by
- 14
- References
- 0
- Citations by year
- 2026: 4 · 2025: 8 · 2024: 2
- FWCI
- 3.69
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Heliyon (publishedVersion, cc-by-nc-nd)
- PubMed Central (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Taichung Veterans General Hospital
- Topics
- Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Pharmacology › Pharmacy and Medical Practices
- Health Sciences › Health Professions › Health Information Management › Electronic Health Records Systems
- Health Sciences › Health Professions › Occupational Therapy › Safe Handling of Antineoplastic Drugs
- Keywords
- automated dispensing cabinets, surgical wards, dispensing errors, nursing satisfaction, pharmacist workload, procedural rules, operating room nursing, integrated information technology, process improvement
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review