Cited by 35Epilepsy research and treatmentCardiovascular Syncope and Autonomic DisordersCardiac pacing and defibrillation studies

Generalized tonic-clonic seizures detected by implantable loop recorder devices: diagnosing more than cardiac arrhythmias

Ho, Reginald T., Wicks, Tammi, Wyeth, Dale, Nei, Maromi·2006·Heart Rhythm

Abstract

Background Both syncope and seizures are important causes of recurrent, unexplained episodes of loss of consciousness. Implantable loop recorders have identified serious arrhythmias in patients with repeated syncope; however, implantable loop recorder detection of seizures is less well established.Objectives The purpose of this study was to provide in-depth analysis of a characteristic myopotential pattern recorded by implantable loop recorders during generalized tonic-clonic seizures.Methods Fourteen patients with refractory, video-EEG-documented epilepsy (complex partial, atonic, tonic, or generalized tonic-clonic seizures) underwent implantable loop recorder placement as part of a study protocol evaluating cardiac rhythm abnormalities in patients at high risk for sudden unexpected death in epilepsy.Results Twelve generalized tonic-clonic seizure episodes were detected by the implantable loop recorder in six patients. Implantable loop recorder and EEG recordings of generalized tonic-clonic seizures were identical and revealed a tonic phase (sustained, rapid, high-frequency myopotentials) transitioning to a clonic phase (periodic bursts of high-frequency myopotentials with a decelerating burst frequency from 3-6 Hz to 1-2 Hz) prior to seizure termination. With the nonprogrammable bandpass filter of 0.85 to 32 Hz in the implantable loop recorder, all generalized tonic-clonic seizure episodes had escaped automatic detection and required activation by family members. None of the 76 nongeneralized tonic-clonic seizure episodes recorded on the implantable loop recorder in the 14 patients exhibited the stereotypical tonic-clonic pattern that defines generalized seizures.Conclusion Recognizing this specific myopotential pattern on an implantable loop recorder might help diagnose generalized tonic-clonic seizures as a cause of recurrent, unexplained episodes of loss of consciousness. Having a programmable bandpass filter in the implantable loop recorder might increase its diagnostic yield for such patients.

Integrity signals

Registry

Crossref · 10.1016/j.hrthm.2006.03.026

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • In patients in whom epilepsy was suspected but the treatment has proven ineffective, an attack could have been documented by ILR in 62% of patients, with an arrhythmic cause being responsible in 26%.

    “Patients in whom epilepsy was suspected but the treatment has proven ineffective: in pooled data, an attack could have been documented by ILR in 62% of patients, with an arrhythmic cause being responsible in 26% 137,189-191”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Ho, R. T., Wicks, T., Wyeth, D., & Nei, M.
Affiliations
Thomas Jefferson University Hospital (US)
Corresponding author
Ho, Reginald T.
Venue
Heart Rhythm
Publisher
Elsevier BV
Published
2006-07
Volume
3
Issue
7
Pages
857-861
ISSN
1547-5271 (ISSN-L)
OpenAlex
W2005546577
Cited by
35
References
17
Citations by year
2025: 2 · 2024: 2 · 2023: 1 · 2021: 1 · 2019: 4 · 2018: 3 · 2016: 1 · 2015: 1 · 2014: 2 · 2013: 3 · 2012: 3
FWCI
1.27
Type
journal article
Language
en
Open access
closed
Locations
  • Heart Rhythm (publishedVersion)
  • PubMed (publishedVersion)
Funders
Medtronic
Topics
  • Health Sciences › Medicine › Psychiatry and Mental health › Epilepsy research and treatment
  • Health Sciences › Medicine › Surgery › Cardiovascular Syncope and Autonomic Disorders
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
Keywords
generalized tonic-clonic seizures, implantable loop recorder, seizure detection, loss of consciousness, syncope, drug-resistant epilepsy, sudden unexpected death in epilepsy, bandpass filter
MeSH terms
Adult, Arrhythmias, Cardiac, Diagnosis, Differential, Electrocardiography, Equipment Design, Female, Humans, Male, Middle Aged, Seizures, Prostheses and Implants

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review