Colchicine for prevention of atrial fibrillation recurrence after pulmonary vein isolation: Mid-term efficacy and effect on quality of life

Deftereos, Spyridon, Giannopoulos, Georgios, Efremidis, Michael, Kossyvakis, Charalampos, Katsivas, Apostolos, Panagopoulou, Vasiliki, Papadimitriou, Charalampos, Karageorgiou, Sofia, Doudoumis, Konstantinos, Raisakis, Konstantinos, Kaoukis, Andreas, Alexopoulos, Dimitrios, Manolis, Antonis S., Stefanadis, Christodoulos, Cleman, Michael W. · 2014 · Heart Rhythm

Abstract

BACKGROUND Our group previously showed that colchicine treatment is associated with decreased early recurrence rate after ablation for atrial fibrillation (AF). OBJECTIVE The purpose of this study was to test the mid-term efficacy of colchicine in reducing AF recurrences after a single procedure of pulmonary vein isolation in patients with paroxysmal AF. Assessment of quality-of-life (QOL) changes was a secondary objective. METHODS Patients with paroxysmal AF who were scheduled for ablation were randomized to a 3-month course of colchicine 0.5 mg twice daily or placebo and were followed for a median of 15 months (with a 3-month blanking period). QOL was assessed with a general-purpose health-related QOL tool (26-item World Health Organization QOL questionnaire) at baseline and after 3 and 12 months. RESULTS Two hundred twenty-three randomized patients underwent ablation, and 206 patients were available for analysis (144 male, age 62.2 ± 5.8 years). AF recurrence rate in the colchicine group was 31.1% (32/103) vs 49.5% (51/103) in the control group (P = .010), translated in a relative risk reduction of 37% (odds ratio 0.46, 95% confidence interval 0.26-0.81). The number needed to treat was 6 (95% confidence interval 3.2-19.8). Physical domain QOL scores at 12 months were 63.6 ± 13.8 in the colchicine group and 52.5 ± 18.1 in controls, whereas psychological domain scores were 56.1 ± 13.7 vs 44.7 ± 17.3, respectively (P <.001, for both). CONCLUSION Colchicine treatment after pulmonary vein isolation for paroxysmal AF is associated with lower AF recurrence rates after a single procedure. This reduction is accompanied by corresponding improvements in physical and psychological health-related QOL scores.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.hrthm.2014.02.002

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 158

Metadata

Authors
Deftereos, S., Giannopoulos, G., Efremidis, M., Kossyvakis, C., Katsivas, A., Panagopoulou, V., Papadimitriou, C., Karageorgiou, S., Doudoumis, K., Raisakis, K., Kaoukis, A., Alexopoulos, D., Manolis, A. S., Stefanadis, C., & Cleman, M. W.
Venue
Heart Rhythm
Publisher
Elsevier BV
Published
2014-04
Volume
11
Issue
4
Pages
620-628
ISSN
1547-5271 (ISSN-L)
OpenAlex
W2171998001
Cited by
158
References
3
FWCI
9.06
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.