2017 HRS/EHRA/ECAS/APHRS/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation
Open accessAbstract
Hugh Calkins, MD (Chair), Gerhard Hindricks, MD (Vice-Chair),* Riccardo Cappato, MD (Vice-Chair), Young-Hoon Kim, MD, PhD (Vice-Chair), Eduardo B. Saad, MD, PhD (Vice-Chair), Luis Aguinaga, MD, PhD, Joseph G. Akar, MD, PhD, Vinay Badhwar, MD, Josep Brugada, MD, PhD,* John Camm, MD,* Peng-Sheng Chen, MD, Shih-Ann Chen, MD, Mina K. Chung, MD, Jens Cosedis Nielsen, DMSc, PhD,* Anne B. Curtis, MD, D. Wyn Davies, MD, John D. Day, MD, André d’Avila, MD, PhD, N.M.S. (Natasja) de Groot, MD, PhD,* Luigi Di Biase, MD, PhD,* Mattias Duytschaever, MD, PhD,* James R. Edgerton, MD, Kenneth A. Ellenbogen, MD, Patrick T. Ellinor, MD, PhD, Sabine Ernst, MD, PhD,* Guilherme Fenelon, MD, PhD, Edward P. Gerstenfeld, MS, MD, David E. Haines, MD, Michel Haissaguerre, MD,* Robert H. Helm, MD, Elaine Hylek, MD, MPH, Warren M. Jackman, MD, Jose Jalife, MD, Jonathan M. Kalman, MBBS, PhD, Josef Kautzner, MD, PhD,* Hans Kottkamp, MD,* Karl Heinz Kuck, MD, PhD,*
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dabigatran versus warfarin in patients with atrial fibrillation
Connolly, S. J., Ezekowitz, M. D., Yusuf, S., Eikelboom, J., Oldgren, J., Parekh, A., Pogue, J., Reilly, P. A., Themeles, E., Varrone, J., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0905561 · Cited by 11,215
Rivaroxaban versus warfarin in nonvalvular atrial fibrillation
Patel, M. R., Mahaffey, K. W., Garg, J., Pan, G., Singer, D. E., Hacke, W., Breithardt, G., Halperin, J. L., Hankey, G. J., Piccini, J. P., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1009638 · Cited by 9,430
Apixaban versus warfarin in patients with atrial fibrillation
Granger, C. B., Alexander, J. H., McMurray, J. J. V., Lopes, R. D., Hylek, E. M., Hanna, M., Al-Khalidi, H. R., Ansell, J., Atar, D., Avezum, A., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1107039 · Cited by 8,943
Wardlaw, J. M., Smith, E. E., Biessels, G. J., Cordonnier, C., Fazekas, F., Frayne, R., Lindley, R. I., O'Brien, J. T., Barkhof, F., Benavente, O. R., et al. (2013) · The Lancet Neurology · doi:10.1016/s1474-4422(13)70124-8 · Cited by 5,544
Edoxaban versus warfarin in patients with atrial fibrillation
Giugliano, R. P., Ruff, C. T., Braunwald, E., Murphy, S. A., Wiviott, S. D., Halperin, J. L., Waldo, A. L., Ezekowitz, M. D., Weitz, J. I., Špinar, J., et al. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1310907 · Cited by 5,164 · cited 2×
“This recommendation is based on the following: (1) recurrences of AF are common both early and late following AF ablation; (2) asymptomatic AF is common, and is more common following AF ablation than prior to AF ablation; (3) AF ablation destroys a portion of the atria and the impact of this on stroke risk is uncertai…”
BackgroundWorldwide Epidemiology of Atrial Fibrillation: A Global Burden of Disease 2010 Study
Chugh, S. S., Havmoeller, R., Narayanan, K., Singh, D., Rienstra, M., Benjamin, E. J., Gillum, R. F., Kim, Y.-H., McAnulty, J. H., Zheng, Z.-J., et al. (2014) · Circulation · doi:10.1161/circulationaha.113.005119 · Cited by 4,506
Self-citationA comparison of rate control and rhythm control in patients with atrial fibrillation
(2002) · New England Journal of Medicine · doi:10.1056/nejmoa021328 · Cited by 4,405 · cited 1×
“During the past 15 years, multiple studies have investigated the impact of rate vs rhythm control on stroke risk and mortality.(52,53,54,55)”
BackgroundSacco, R. L., Kasner, S. E., Broderick, J. P., Caplan, L. R., Connors, J. J. (., Culebras, A., Elkind, M. S. V., George, M. G., Hamdan, A. D., Higashida, R. T., et al. (2013) · Stroke · doi:10.1161/str.0b013e318296aeca · Cited by 3,569
Cappato, R., Calkins, H., Chen, S.-A., Davies, W., Iesaka, Y., Kalman, J., Kim, Y.-H., Klein, G., Natale, A., Packer, D., et al. (2010) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.109.859116 · Cited by 2,852 · cited 23×
“It is difficult to directly compare adverse events from AF ablation to those from AADs.”
BackgroundMethodResultInfluentialBenjamin, E. J. (1994) · JAMA · doi:10.1001/jama.1994.03510350050036 · Cited by 2,613
Cited by
2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy
Glikson, M., Nielsen, J. C., Kronborg, M. B., Michowitz, Y., Auricchio, A., Barbash, I. M., Barrabés, J. A., Boriani, G., Braunschweig, F., Brignole, M., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab364 · Cited by 2,019
Self-citationSteffel, J., Collins, R., Antz, M., Cornu, P., Desteghe, L., Haeusler, K. G., Oldgren, J., Reinecke, H., Roldan-Schilling, V., Rowell, N., et al. (2021) · EP Europace · doi:10.1093/europace/euab065 · Cited by 1,132
Self-citationAntithrombotic Therapy for Atrial Fibrillation
Lip, G. Y. H., Banerjee, A., Boriani, G., Chiang, C. E., Fargo, R., Freedman, B., Lane, D. A., Ruff, C. T., Turakhia, M., Werring, D., et al. (2018) · Chest · doi:10.1016/j.chest.2018.07.040 · Cited by 939
Self-citation2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy
Glikson, M., Nielsen, J. C., Kronborg, M. B., Michowitz, Y., Auricchio, A., Barbash, I. M., Barrabés, J. A., Boriani, G., Braunschweig, F., Brignole, M., et al. (2022) · EP Europace · doi:10.1093/europace/euab232 · Cited by 914
Self-citationCryoballoon Ablation as Initial Therapy for Atrial Fibrillation
Wazni, O. M., Dandamudi, G., Sood, N., Hoyt, R., Tyler, J., Durrani, S., Niebauer, M., Makati, K., Halperin, B., Gauri, A., et al. (2021) · New England Journal of Medicine · doi:10.1056/nejmoa2029554 · Cited by 649
Metadata
- Authors
- Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., Chen, P.-S., Chen, S.-A., Chung, M. K., Cosedis Nielsen, J., Curtis, A. B., Davies, D. W., Day, J. D., d’Avila, A., (Natasja) de Groot, N. M. S., Di Biase, L., Duytschaever, M., Edgerton, J. R., Ellenbogen, K. A., Ellinor, P. T., Ernst, S., Fenelon, G., Gerstenfeld, E. P., Haines, D. E., Haissaguerre, M., Helm, R. H., Hylek, E., Jackman, W. M., Jalife, J., Kalman, J. M., Kautzner, J., Kottkamp, H., Kuck, K. H., Kumagai, K., Lee, R., Lewalter, T., Lindsay, B. D., Macle, L., Mansour, M., Marchlinski, F. E., Michaud, G. F., Nakagawa, H., Natale, A., Nattel, S., Okumura, K., Packer, D., Pokushalov, E., Reynolds, M. R., Sanders, P., Scanavacca, M., Schilling, R., Tondo, C., Tsao, H.-M., Verma, A., Wilber, D. J., Yamane, T., Reviewers:, D., Blomström-Lundqvist, C., De Paola, A. A. V., Kistler, P. M., Lip, G. Y. H., Peters, N. S., Pisani, C. F., Raviele, A., Saad, E. B., Satomi, K., Stiles, M. K., & Willems, S.
- Venue
- EP Europace
- Publisher
- Oxford University Press (OUP)
- Published
- 2017-09-15
- Volume
- 20
- Issue
- 1
- Pages
- e1-e160
- ISSN
- 1099-5129 (ISSN-L)
- 1532-2092
- OpenAlex
- W4241261201
- Cited by
- 1,164
- References
- 118
- FWCI
- 67.77
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: 2017 HRS/EHRA/ECAS/APHRS/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation. https://app.cochat.ai/papers/10.1093/europace/eux274
- The paper
- Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., Chen, P.-S., Chen, S.-A., Chung, M. K., Cosedis Nielsen, J., Curtis, A. B., Davies, D. W., Day, J. D., d’Avila, A., (Natasja) de Groot, N. M. S., . . . Willems, S. (2018). 2017 HRS/EHRA/ECAS/APHRS/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation. EP Europace. https://doi.org/10.1093/europace/eux274
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.