Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 210

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Predicting atrial fibrillation ablation outcome: The CAAP-AF score

Open access
Winkle, Roger A., Jarman, Julian W.E., Mead, R. Hardwin, Engel, Gregory, Kong, Melissa H., Fleming, William, Patrawala, Rob A. · 2016 · Heart Rhythm

Abstract

BACKGROUND: Patients with a variety of clinical presentations undergo atrial fibrillation (AF) ablation. Long-term ablation success rates can vary considerably. OBJECTIVE: The purpose of this study was to develop a clinical scoring system to predict long-term freedom from AF after ablation. METHODS: We retrospectively derived the scoring system on a development cohort (DC) of 1125 patients undergoing AF ablation and tested it prospectively in a test cohort (TC) of 937 patients undergoing AF ablation. RESULTS: The demographics of the DC patients were as follows: age 62.3 ± 10.3 years, male sex 801 (71.2%), left atrial size 4.30 ± 0.69 cm, paroxysmal AF 348 (30.9%), number of drugs failed 1.3 ± 1.1, hypertension 525 (46.7%), diabetes 100 (8.9%), prior stroke/transient ischemic attack 78 (6.9%), prior cardioversion 528 (46.9%), and CHADS2 score 0.87 ± 0.97. Multivariate analysis showed 6 independent variables predicting freedom from AF after final ablation: coronary artery disease (P = .021), atrial diameter (P = .0003), age (P = .004), persistent or long-standing AF (P < .0001), number of antiarrhythmic drugs failed (P < .0001), and female sex (P = .0001). We created a scoring system (CAAP-AF) using these 6 variables, with scores ranging from 0 to 13 points. The 2-year AF-free rates by CAAP-AF scores were as follows: 0 = 100%, 1 = 95.7%, 2 = 96.3%, 3 = 83.1%, 4 = 85.5%, 5 = 79.9%, 6 = 76.1%, 7 = 63.4%, 8 = 51.1%, 9 = 53.6%, and ≥10 = 29.1%. Ablation success decreased as CAAP-AF scores increased (P < .0001). The CAAP-AF score also predicted freedom from AF in the TC. The 2-year Kaplan-Meier AF-free rates by CAAP-AF scores were as follows: 0 = 100%, 1 = 87.0%, 2 = 89.0%, 3 = 91.6%, 4 = 90.5%, 5 = 84.4%, 6 = 70.1%, 7 = 71.0%, 8 = 60.7%, 9 = 68.9%, and ≥10 = 51.3%. As CAAP-AF scores increased, 2-year freedom from AF in the TC decreased (P < .0001). CONCLUSION: An easily determined clinical scoring system was derived retrospectively and applied prospectively. The CAAP-AF score predicted freedom from AF after ablation in both a DC and a TC of patients undergoing AF ablation. The CAAP-AF score provides a realistic AF ablation outcome expectation for individual patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.hrthm.2016.07.018

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 210

Metadata

Authors
Winkle, R. A., Jarman, J. W. E., Mead, R. H., Engel, G., Kong, M. H., Fleming, W., & Patrawala, R. A.
Venue
Heart Rhythm
Publisher
Elsevier BV
Published
2016-11
Volume
13
Issue
11
Pages
2119-2125
ISSN
1547-5271 (ISSN-L)
OpenAlex
W2498305138
Cited by
210
References
2
FWCI
12.70
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.