The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
On-treatment comparison between corrective His bundle pacing and biventricular pacing for cardiac resynchronization: A secondary analysis of the His-SYNC Pilot Trial
Abstract
BACKGROUND The His-SYNC pilot trial was the first randomized comparison between His bundle pacing in lieu of a left ventricular lead for cardiac resynchronization therapy (His-CRT) and biventricular pacing (BiV-CRT), but was limited by high rates of crossover. OBJECTIVE To evaluate the results of the His-SYNC pilot trial utilizing treatment-received (TR) and per-protocol (PP) analyses. METHODS The His-SYNC pilot was a multicenter, prospective, single-blinded, randomized, controlled trial comparing His-CRT vs BiV-CRT in patients meeting standard indications for CRT (eg, NYHA II-IV patients with QRS >120 ms). Crossovers were required based on prespecified criteria. The primary endpoints analyzed included improvement in QRS duration, left ventricular ejection fraction (LVEF), and freedom from cardiovascular (CV) hospitalization and mortality. RESULTS Among 41 patients enrolled (aged 64 ± 13 years, 38% female, LVEF 28%, QRS 168 ± 18 ms), 21 were randomized to His-CRT and 20 to BiV-CRT. Crossover occurred in 48% of His-CRT and 26% of BiV-CRT. The most common reason for crossover from His-CRT was inability to correct QRS owing to nonspecific intraventricular conduction delay (n = 5). Patients treated with His-CRT demonstrated greater QRS narrowing compared to BiV (125 ± 22 ms vs 164 ± 25 ms [TR], P < .001;124 ± 19 ms vs 162 ± 24 ms [PP], P < .001). A trend toward higher echocardiographic response was also observed (80 vs 57% [TR], P = .14; 91% vs 54% [PP], P = .078). No significant differences in CV hospitalization or mortality were observed. CONCLUSIONS Patients receiving His-CRT on-treatment demonstrated superior electrical resynchronization and a trend toward higher echocardiographic response than BiV-CRT. Larger prospective studies may be justifiable with refinements in patient selection and implantation techniques to minimize crossovers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bristow, M. R., Saxon, L. A., Boehmer, J., Krueger, S., Kass, D. A., De Marco, T., Carson, P., DiCarlo, L., DeMets, D., White, B. G., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032423 · Cited by 5,812 · cited 1×
“COMPANION and CARE-HF were the initial landmark trials to demonstrate mortality benefit in patients undergoing CRT with BiV compared to medical therapy.(1,2) Improvements in LVEF have been inconsistently correlated with the magnitude of QRS narrowing,(23) although when dichotomized, increases in paced QRS duration(24)…”
Cardiac-Resynchronization Therapy for the Prevention of Heart-Failure Events
Moss, A. J., Hall, W. J., Cannom, D. S., Klein, H., Brown, M. W., Daubert, J. P., Estes, N. A. M., Foster, E., Greenberg, H., Higgins, S. L., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0906431 · Cited by 3,157
Cardiac-Resynchronization Therapy in Heart Failure with a Narrow QRS Complex
Ruschitzka, F., Abraham, W. T., Singh, J. P., Bax, J. J., Borer, J. S., Brugada, J., Dickstein, K., Ford, I., Gorcsan, J., Gras, D., et al. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1306687 · Cited by 825
Huang, W., Su, L., Wu, S., Xu, L., Xiao, F., Zhou, X., & Ellenbogen, K. A. (2017) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2017.09.013 · Cited by 736
Superior Vena Cava Defibrillator Coils Make Transvenous Lead Extraction More Challenging and Riskier
Epstein, L. M., Love, C. J., Wilkoff, B. L., Chung, M. K., Hackler, J. W., Bongiorni, M. G., Segreti, L., Carrillo, R. G., Baltodano, P., Fischer, A., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.12.014 · Cited by 467
His Corrective Pacing or Biventricular Pacing for Cardiac Resynchronization in Heart Failure
Upadhyay, G. A., Vijayaraman, P., Nayak, H. M., Verma, N., Dandamudi, G., Sharma, P. S., Saleem, M., Mandrola, J., Genovese, D., & Tung, R. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2019.04.026 · Cited by 249
Self-citationIler, M. A., Hu, T., Ayyagari, S., Callahan, T. D., Civello, K. C., Thal, S. G., Wilkoff, B. L., & Chung, M. K. (2008) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2007.08.043 · Cited by 49
Cited by
Heidenreich, P. A., Bozkurt, B., Aguilar, D., Allen, L. A., Byun, J. J., Colvin, M. M., Deswal, A., Drazner, M. H., Dunlay, S. M., Evers, L. R., et al. (2022) · Circulation · doi:10.1161/cir.0000000000001063 · Cited by 4,922
2022 AHA/ACC/HFSA Guideline for the Management of Heart Failure
Heidenreich, P. A., Bozkurt, B., Aguilar, D., Allen, L. A., Byun, J. J., Colvin, M. M., Deswal, A., Drazner, M. H., Dunlay, S. M., Evers, L. R., et al. (2022) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2021.12.012 · Cited by 2,862
2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy
Glikson, M., Nielsen, J. C., Kronborg, M. B., Michowitz, Y., Auricchio, A., Barbash, I. M., Barrabés, J. A., Boriani, G., Braunschweig, F., Brignole, M., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab364 · Cited by 2,019
2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy
Glikson, M., Nielsen, J. C., Kronborg, M. B., Michowitz, Y., Auricchio, A., Barbash, I. M., Barrabés, J. A., Boriani, G., Braunschweig, F., Brignole, M., et al. (2022) · EP Europace · doi:10.1093/europace/euab232 · Cited by 914
Chung, M. K., Patton, K. K., Lau, C.-P., Dal Forno, A. R. J., Al-Khatib, S. M., Arora, V., Birgersdotter-Green, U. M., Cha, Y.-M., Chung, E. H., Cronin, E. M., et al. (2023) · Heart Rhythm · doi:10.1016/j.hrthm.2023.03.1538 · Cited by 548
Self-citation
Metadata
- Authors
- Upadhyay, G. A., Vijayaraman, P., Nayak, H. M., Verma, N., Dandamudi, G., Sharma, P. S., Saleem, M., Mandrola, J., Genovese, D., Oren, J. W., Subzposh, F. A., Aziz, Z., Beaser, A., Shatz, D., Besser, S., Lang, R. M., Trohman, R. G., Knight, B. P., & Tung, R.
- Venue
- Heart Rhythm
- Publisher
- Elsevier BV
- Published
- 2019-12
- Volume
- 16
- Issue
- 12
- Pages
- 1797-1807
- ISSN
- 1547-5271 (ISSN-L)
- OpenAlex
- W2946775122
- Cited by
- 230
- References
- 7
- FWCI
- 17.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: On-treatment comparison between corrective His bundle pacing and biventricular pacing for cardiac resynchronization: A secondary analysis of the His-SYNC Pilot Trial. https://app.cochat.ai/papers/10.1016/j.hrthm.2019.05.009
- The paper
- Upadhyay, G. A., Vijayaraman, P., Nayak, H. M., Verma, N., Dandamudi, G., Sharma, P. S., Saleem, M., Mandrola, J., Genovese, D., Oren, J. W., Subzposh, F. A., Aziz, Z., Beaser, A., Shatz, D., Besser, S., Lang, R. M., Trohman, R. G., Knight, B. P., & Tung, R. (2019). On-treatment comparison between corrective His bundle pacing and biventricular pacing for cardiac resynchronization: A secondary analysis of the His-SYNC Pilot Trial. Heart Rhythm. https://doi.org/10.1016/j.hrthm.2019.05.009
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.