A beginner's guide to permanent left bundle branch pacing
Open accessAbstract
Introduction Studies have demonstrated the feasibility and clinical benefits of permanent His-bundle pacing (HBP). However, concerns regarding higher pacing thresholds, lower R-wave amplitudes, and the potential to develop distal conduction block have limited the clinical application of HBP in certain subgroups. Thus, left bundle branch pacing (LBBP) has emerged as an alternative method for delivering physiological pacing to achieve electrical synchrony of the left ventricle (LV), especially in patients with infranodal atrioventricular block and left bundle branch block (LBBB). The proximal left bundle branches run through the LV septum and fan out to form a wider target for pacing compared to the His bundle. Recently, we reported that HBP can correct classic LBBB in 97% of patients, and Upadhyay et al demonstrated that the site of block usually is located within the His or proximal left bundle. We developed a technique for LBBP using a transseptal approach. LBBP has been reported to offer low pacing thresholds and large R waves, and because the distal conduction system is targeted, has a lower theoretical risk for development of distal conduction block. However, the definitions and implantation procedure have not been previously well described. Here we describe our method for performing LBBP to confirm intraseptal left con-
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, W., Su, L., Wu, S., Xu, L., Xiao, F., Zhou, X., & Ellenbogen, K. A. (2017) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2017.09.013 · Cited by 736
Self-citationVijayaraman, P., Subzposh, F. A., Naperkowski, A., Panikkath, R., John, K., Mascarenhas, V., Bauch, T. D., & Huang, W. (2019) · Heart Rhythm · doi:10.1016/j.hrthm.2019.05.011 · Cited by 396
Self-citationVijayaraman, P., Chung, M. K., Dandamudi, G., Upadhyay, G. A., Krishnan, K., Crossley, G., Bova Campbell, K., Lee, B. K., Refaat, M. M., Saksena, S., et al. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.06.017 · Cited by 350
Self-citation
Cited by
2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy
Glikson, M., Nielsen, J. C., Kronborg, M. B., Michowitz, Y., Auricchio, A., Barbash, I. M., Barrabés, J. A., Boriani, G., Braunschweig, F., Brignole, M., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab364 · Cited by 2,019
Strocchi, M., Lee, A. W. C., Neic, A., Bouyssier, J., Gillette, K., Plank, G., Elliott, M. K., Gould, J., Behar, J. M., Sidhu, B., et al. (2020) · Heart Rhythm · doi:10.1016/j.hrthm.2020.06.028 · Cited by 73
Metadata
- Authors
- Huang, W., Chen, X., Su, L., Wu, S., Xia, X., & Vijayaraman, P.
- Venue
- Heart Rhythm
- Publisher
- Elsevier BV
- Published
- 2019-12
- Volume
- 16
- Issue
- 12
- Pages
- 1791-1796
- ISSN
- 1547-5271 (ISSN-L)
- OpenAlex
- W2950614089
- Cited by
- 651
- References
- 3
- FWCI
- 50.53
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A beginner's guide to permanent left bundle branch pacing. https://app.cochat.ai/papers/10.1016/j.hrthm.2019.06.016
- The paper
- Huang, W., Chen, X., Su, L., Wu, S., Xia, X., & Vijayaraman, P. (2019). A beginner's guide to permanent left bundle branch pacing. Heart Rhythm. https://doi.org/10.1016/j.hrthm.2019.06.016
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.