Cited by 30Non-Invasive Vital Sign MonitoringHemodynamic Monitoring and TherapyHealthcare Technology and Patient Monitoring

Comparison of nasal and forehead oximetry accuracy and pressure injury in critically ill patients

Schallom, Marilyn, Prentice, Donna, Sona, Carrie, Arroyo, Cassandra, Mazuski, John·2018·Heart & Lung

Abstract

Background In critically ill patients, clinicians can have difficulty obtaining accurate oximetry measurements.Objective To compare the accuracy of nasal alar and forehead sensor measurements and incidence of pressure injury.Methods 43 patients had forehead and nasal alar sensors applied. Arterial samples were obtained at 0, 24, and 120 hours. Oxygen saturations measured by co-oximetry were compared to sensor values. Skin was assessed every 8 hours.Results Oxygen saturations ranged from 69.8%-97.8%, with 18% of measures < 90%. Measurements were within 3% of co-oximetry values for 54% of nasal alar compared to 35% of forehead measurements. Measurement failures occurred in 6% for nasal alar and 22% for forehead. Three patients developed a pressure injury with the nasal alar sensor and 13 patients developed a pressure injury with the forehead sensor (χ2 = 7.68; p = .006).Conclusions In this group of patients with decreased perfusion, nasal alar sensors provided a potential alternative for continuous monitoring of oxygen saturation.

Integrity signals

Registry

Crossref · 10.1016/j.hrtlng.2017.12.002

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • When measurement bias and precision are considered jointly in Arms, pulse oximetry measurements for all the subgroups appear acceptably accurate, with Arms below the internationally recommended threshold of 4% or the more conservative US FDA threshold of 3%.

    “Nevertheless, when the extents of measurement bias and precision are considered jointly in Arms, pulse oximetry measurements for all the subgroups appear acceptably accurate (with Arms < the internationally recommended threshold of 4% [10, 55], or even the more conservative threshold of 3% in the US FDA guidance) [56].”

The citation lists haven’t been fetched yet

References 21 · Cited by 30

Authors
Schallom, M., Prentice, D., Sona, C., Arroyo, C., & Mazuski, J.
Affiliations
  • Barnes-Jewish Hospital (US)
  • Washington University in St. Louis (US)
Corresponding author
Schallom, Marilyn
Venue
Heart & Lung
Publisher
Elsevier BV
Published
2018-03
Volume
47
Issue
2
Pages
93-99
ISSN
0147-9563 (ISSN-L)
OpenAlex
W2793433978
Cited by
30
References
21
Citations by year
2026: 1 · 2025: 2 · 2024: 1 · 2023: 1 · 2022: 23 · 2021: 1 · 2020: 1
FWCI
0.20
Type
journal article
Language
en
Open access
closed
Locations
  • Heart & Lung (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
  • Health Sciences › Medicine › Surgery › Healthcare Technology and Patient Monitoring
Keywords
oxygen saturation monitoring, sensor accuracy, pressure ulcers, critically ill patients, co-oximetry, measurement failure, skin assessment, hypoperfusion
MeSH terms
Adult, Aged, Arteries, Critical Care, Pressure Ulcer, Female, Forehead, Humans, Male, Middle Aged, Nose, Oximetry, Oxygen, Pressure, Prospective Studies, Skin, Critical Illness

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review