The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Preparation and in vitro characterization of cross-linked collagen–gelatin hydrogel using EDC/NHS for corneal tissue engineering applications
Abstract
Corneal disease is considered as the second leading cause of vision loss and keratoplasty is known as an effective treatment for it. However, the tissue engineered corneal substitutes are promising tools in experimental in vivo repair of cornea. Selecting appropriate cell sources and scaffolds are two important concerns in corneal tissue engineering. The object of this study was to investigate biocompatibility and physical properties of the bio-engineered cornea, fabricated from type-I collagen (COL) and gelatin (Gel). Two gelatin based hydrogels cross-linked with EDC/NHS were fabricated, and their physicochemical properties such as equilibrium water content, enzymatic degradation, mechanical properties, rheological, contact angle and optical properties as well as their ability to support human bone-marrow mesenchymal stem cells (hBM-MSCs) survival were characterized. The equilibrium water content and enzymatic degradation of these hydrogels can be easily controlled by adding COL. Our findings suggest that incorporation of COL-I increases optical properties, hydrophilicity, stiffness and Young's modulus. The viability of hBM-MSCs cultured in Gel and Gel: COL was assessed via CCK-8 assay. Also, the morphology of the hBM-MSCs on the top of Gel and Gel: COL hydrogels were characterized by phase-contrast microscopy. This biocompatible hydrogel may promise to be used as artificial corneal substitutes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tonsomboon, K., & Oyen, M. L. (2013) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2013.03.001 · Cited by 207
Cited by
Krishani, M., Shin, W. Y., Suhaimi, H., & Sambudi, N. S. (2023) · Gels · doi:10.3390/gels9020100 · Cited by 328
Bagheri, M., Validi, M., Gholipour, A., Makvandi, P., & Sharifi, E. (2022) · Bioengineering & Translational Medicine · doi:10.1002/btm2.10254 · Cited by 268
Self-citationCollagen Based Materials in Cosmetic Applications: A Review
Sionkowska, A., Adamiak, K., Musiał, K., & Gadomska, M. (2020) · Materials · doi:10.3390/ma13194217 · Cited by 198
Bhattacharjee, P., & Ahearne, M. (2021) · Pharmaceutics · doi:10.3390/pharmaceutics13030319 · Cited by 66
Luo, Y., Huang, S., & Ma, L. (2021) · Biomedical Materials · doi:10.1088/1748-605x/ac0088 · Cited by 25
Metadata
- Authors
- Goodarzi, H., Jadidi, K., Pourmotabed, S., Sharifi, E., & Aghamollaei, H.
- Venue
- International Journal of Biological Macromolecules
- Publisher
- Elsevier BV
- Published
- 2019-04
- Volume
- 126
- Pages
- 620-632
- ISSN
- 0141-8130 (ISSN-L)
- OpenAlex
- W2904610484
- Cited by
- 220
- References
- 1
- FWCI
- 6.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Preparation and in vitro characterization of cross-linked collagen–gelatin hydrogel using EDC/NHS for corneal tissue engineering applications. https://app.cochat.ai/papers/10.1016/j.ijbiomac.2018.12.125
- The paper
- Goodarzi, H., Jadidi, K., Pourmotabed, S., Sharifi, E., & Aghamollaei, H. (2019). Preparation and in vitro characterization of cross-linked collagen–gelatin hydrogel using EDC/NHS for corneal tissue engineering applications. International Journal of Biological Macromolecules. https://doi.org/10.1016/j.ijbiomac.2018.12.125
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.