A novel gene recombinant collagen hemostatic sponge with excellent biocompatibility and hemostatic effect
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Effect and biosafety are the most noteworthy aspect of the hemostatic materials for trauma treatment. In this work, we evaluated the biocompatibility and hemostatic effect of a novel recombinant collagen hemostatic sponge according to ISO 10993. In addition, the interaction between the recombinant collagen hemostatic sponge and blood cells was observed by scanning electron microscopy, moreover, the hemostatic effect was evaluated by blood clotting assay in vitro and liver hemorrhage models in vivo. As the results, the novel recombinant collagen hemostatic sponge enables to be biodegradable completely in vivo, without stimulation, sensitization, acute toxicity, hematolysis or obvious immune rejection. The procoagulant effect of recombinant hemostatic sponge in vitro is significantly more excellent than that of natural collagen sponge due to the more promotive capacity of blood cell adhesion. Meanwhile, the liver hemorrhage models showed that the hemostatic time of recombinant collagen sponge was 19.33 ± 4.64 s, which was significantly better than that of natural collagen sponge (hemostatic time 31.62 ± 5.63 s). Therefore, the novel recombinant collagen hemostatic sponge with satisfactory biocompatibility and significant hemostatic effect can be performed as a potential novel type of clinical hemostatic products for research and development.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The application of recombinant human collagen in tissue engineering
Yang, C., Hillas, P. J., B??ez, J. A., Nokelainen, M., Balan, J., Tang, J., Spiro, R., & Polarek, J. W. (2004) · BioDrugs · doi:10.2165/00063030-200418020-00004 · Cited by 385
EDC Cross-linking of Decellularized Tissue: A Promising Approach?
Lehmann, N., Christ, T., Daugs, A., Bloch, O., & Holinski, S. (2017) · Tissue Engineering Part A · doi:10.1089/ten.tea.2016.0416 · Cited by 30
Cited by
Wang, Y., Zhai, W., Cheng, S., Li, J., & Zhang, H. (2023) · Friction · doi:10.1007/s40544-022-0710-x · Cited by 216
“[82] He Y, Wang J, Si Y, Wang X, Deng H, Sheng Z, Li Y, Liu J, Zhao J.”
BackgroundSalvatore, L., Gallo, N., Natali, M. L., Terzi, A., Sannino, A., & Madaghiele, M. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.644595 · Cited by 181
Emerging materials for hemostasis
Li, X.-F., Lu, P., Jia, H.-R., Li, G., Zhu, B., Wang, X., & Wu, F.-G. (2023) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2022.214823 · Cited by 164
Self-citationRani Raju, N., Silina, E., Stupin, V., Manturova, N., Chidambaram, S. B., & Achar, R. R. (2022) · Pharmaceutics · doi:10.3390/pharmaceutics14081574 · Cited by 160
“Perfect biocompatibility with no sensitivity, no toxicity, no stimulation reactions observed and excellent haemostatic effect [97] Saline, rCOL sponge extraction”
BackgroundDesign of biopolymer-based hemostatic material: Starting from molecular structures and forms
Zou, C.-Y., Li, Q.-J., Hu, J.-J., Song, Y.-T., Zhang, Q.-Y., Nie, R., Li-Ling, J., & Xie, H.-Q. (2022) · Materials Today Bio · doi:10.1016/j.mtbio.2022.100468 · Cited by 87
Metadata
- Authors
- He, Y., Wang, J., Si, Y., Wang, X., Deng, H., Sheng, Z., Li, Y., Liu, J., & Zhao, J.
- Venue
- International Journal of Biological Macromolecules
- Publisher
- Elsevier BV
- Published
- 2021-05
- Volume
- 178
- Pages
- 296-305
- ISSN
- 0141-8130 (ISSN-L)
- OpenAlex
- W3130475923
- Cited by
- 103
- References
- 2
- FWCI
- 9.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.