Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 244

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

IRON-HF study: A randomized trial to assess the effects of iron in heart failure patients with anemia

Open access
Beck-da-Silva, Luís, Piardi, Diogo, Soder, Stephan, Rohde, Luís Eduardo, Pereira-Barretto, Antônio Carlos, de Albuquerque, Denílson, Bocchi, Edimar, Vilas-Boas, Fábio, Moura, Lídia Zytynzki, Montera, Marcelo W., Rassi, Salvador, Clausell, Nadine·2013·International Journal of Cardiology

Abstract

BACKGROUND Anemia in heart failure patients and has been associated with increased morbi-mortality. Previous studies have treated anemia in heart failure patients with either erythropoietin alone or combination of erythropoietin and intravenous (i.v.) iron. However, the effect of i.v. or oral (p.o.) iron supplementation alone in heart failure patients with anemia was virtually unknown. AIM To compare, in a double-blind design, the effects of i.v. iron versus p.o. iron in anemic heart failure patients. METHODS IRON-HF study was a multicenter, investigator initiated, randomized, double-blind, placebo controlled trial that enrolled anemic heart failure patients with preserved renal function, low transferrin saturation (TSat) and low-to-moderately elevated ferritin levels. Interventions were Iron Sucrose i.v. 200 mg, once a week, for 5 weeks, ferrous sulfate 200 mg p.o. TID, for 8 weeks, or placebo. Primary endpoint was variation of peak oxygen consumption (peak VO2) assessed by ergospirometry over 3 month follow-up. RESULTS Eighteen patients had full follow-up data. There was an increment of 3.5 ml/kg/min in peak VO2 in the i.v. iron group. There was no increment in peak VO2 in the p.o. iron group. Patients' ferritin and TSat increased significantly in both treated groups. Hemoglobin increased similarly in all groups. CONCLUSION I.v. iron seems to be superior in improving functional capacity of heart failure patients. However, correction of anemia seems to be at least similar between p.o. iron and i.v. iron supplementation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ijcard.2013.04.181

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 244

Metadata

Authors
Beck-da-Silva, L., Piardi, D., Soder, S., Rohde, L. E., Pereira-Barretto, A. C., de Albuquerque, D., Bocchi, E., Vilas-Boas, F., Moura, L. Z., Montera, M. W., Rassi, S., & Clausell, N.
Venue
International Journal of Cardiology
Publisher
Elsevier BV
Published
2013-10
Volume
168
Issue
4
Pages
3439-3442
ISSN
0167-5273 (ISSN-L)
OpenAlex
W1997355335
Cited by
244
References
5
FWCI
9.81
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: IRON-HF study: A randomized trial to assess the effects of iron in heart failure patients with anemia. https://app.cochat.ai/papers/10.1016/j.ijcard.2013.04.181
The paper
Beck-da-Silva, L., Piardi, D., Soder, S., Rohde, L. E., Pereira-Barretto, A. C., de Albuquerque, D., Bocchi, E., Vilas-Boas, F., Moura, L. Z., Montera, M. W., Rassi, S., & Clausell, N. (2013). IRON-HF study: A randomized trial to assess the effects of iron in heart failure patients with anemia. International Journal of Cardiology. https://doi.org/10.1016/j.ijcard.2013.04.181

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.