The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
DE optimized parallel 2-DOF PID controller for load frequency control of power system with governor dead-band nonlinearity
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Storn, R., & Price, K. (1997) · Journal of Global Optimization · doi:10.1023/a:1008202821328 · Cited by 29,569
Power System Stability and Control
Kundur, P. (1994) · Cited by 19,639
Ogata, K., & Brewer, J. W. (1971) · Journal of Dynamic Systems, Measurement, and Control · doi:10.1115/1.3426465 · Cited by 6,358
Differential Evolution: A Survey of the State-of-the-Art
Das, S., & Suganthan, P. N. (2011) · IEEE Transactions on Evolutionary Computation · doi:10.1109/tevc.2010.2059031 · Cited by 5,307
Price, K. V. (2004) · Cited by 3,344
Power System Stability and Control
(2007) · CRC Press eBooks · doi:10.1201/9781420009248 · Cited by 1,828
Electric Energy Systems Theory: An Introduction
Elgerd, O. I., & Happ, H. H. (1972) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1972.4309116 · Cited by 1,045
尾形, 克. (1990) · Prentice Hall eBooks · Cited by 633
Unified Tuning of PID Load Frequency Controller for Power Systems via IMC
Tan, W. (2010) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2009.2036463 · Cited by 526
Ali, E. S., & Elazim, S. M. A. (2011) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2010.12.022 · Cited by 486
Nanda, J., Mishra, S., & Saikia, L. C. (2009) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2009.2016588 · Cited by 411
Adaptive fuzzy gain scheduling for load frequency control
Talaq, J., & Al-Basri, F. (1999) · IEEE Transactions on Power Systems · doi:10.1109/59.744505 · Cited by 370
Load frequency control of a realistic power system with multi-source power generation
Parmar, K. P. S., Majhi, S., & Kothari, D. P. (2012) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2012.04.040 · Cited by 364
A reinforcement learning approach to automatic generation control
Imthias Ahamed, T. P., Nagendra Rao, P. S., & Sastry, P. S. (2002) · Electric Power Systems Research · doi:10.1016/s0378-7796(02)00088-3 · Cited by 205
Multi-area adaptive LFC developed for a comprehensive AGC simulator
Shoults, R. R., & Ibarra, J. (1993) · IEEE Transactions on Power Systems · doi:10.1109/59.260829 · Cited by 95
Cited by
Mohanty, B., Panda, S., & Hota, P. K. (2014) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2013.06.029 · Cited by 438
Self-citationAlhelou, H. H., Hamedani-Golshan, M.-E., Zamani, R., Heydarian-Forushani, E., & Siano, P. (2018) · Energies · doi:10.3390/en11102497 · Cited by 349
Decentralized Sliding Mode Load Frequency Control for Multi-Area Power Systems
Mi, Y., Fu, Y., Wang, C., & Wang, P. (2013) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2013.2277131 · Cited by 337
Sahu, R. K., Panda, S., & Padhan, S. (2015) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2014.07.013 · Cited by 327
Self-citationSahu, R. K., Panda, S., & Chandra Sekhar, G. T. (2015) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2014.08.021 · Cited by 319
Self-citation
Metadata
- Authors
- Sahu, R. K., Panda, S., & Rout, U. K.
- Venue
- International Journal of Electrical Power & Energy Systems
- Publisher
- Elsevier BV
- Published
- 2013-07
- Volume
- 49
- Pages
- 19-33
- ISSN
- 0142-0615 (ISSN-L)
- OpenAlex
- W2006898563
- Cited by
- 343
- References
- 15
- FWCI
- 15.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.