The DOI matches its Crossref record.
A novel three-phase four-leg inverter based load unbalance compensator for stand-alone microgrid
Open accessAbstract
This paper proposes a three-phase four-leg voltage sourced inverter (VSI) based load unbalance compensator (LUC) including its control algorithm, which is a component of a microgrid. The purpose of proposed three-phase four-leg VSI based LUC is to improve power quality of the standalone microgrid. Power quality of the microgrid which was installed in Mara-island, Korea is analyzed using a real operational data. In this work, the microgrid in Mara-island which includes a photovoltaic power generation system, a diesel generator, a battery energy storage system, and a power management system is modeled in PSCAD/EMTDC, and proposed three-phase four-leg VSI based LUC is also modeled and applies to the modeled microgrid. Power flow and stability of the modeled microgrid with the LUC is analyzed under variable irradiance and unbalance loads. The results show that the proposed LUC helps to improve stability of the stand-alone microgrid. The proposed three-phase four-leg VSI based LUC and its control algorithm can be effectively utilized to the stand alone microgrid which has large unbalance loads.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The four-leg converter outperforms the conventional three-leg converters in terms of the degree of freedom and better control capability [72].”
From State of the Art of Solid-State Transformers: Advanced Topologies, Implementation Issues, Recent Progress and Improvements (2020) · cites this paper as [72]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 21
- Habibi, 2013, Electr Power Energy Syst, 44, 656, 10.1016/j.ijepes.2012.08.023 · DOI
- Al-Saedi, 2013, Electr Power Energy Syst, 42, 139, 10.1016/j.ijepes.2012.04.007 · DOI
- Huang, 2013, Electr Power Energy Syst, 43, 1127, 10.1016/j.ijepes.2012.06.068 · DOI
- Al-Saedi, 2013, Electr Power Energy Syst, 49, 76, 10.1016/j.ijepes.2012.12.017 · DOI
- Katiraei, 2008, IEEE Power Energy Mag, 54, 10.1109/MPE.2008.918702 · DOI
- Bauer P, Weldemariam LE, Raijen E. In: IEEE 33rd international telecommunications energy conference; 2011. p. 1–10. · DOI
- Hatziargyriou, 2007, IEEE Power Energy Mag, 78, 10.1109/MPAE.2007.376583 · DOI
- Shahnia, 2010, Electr Power Syst Res, 80, 954, 10.1016/j.epsr.2010.01.005 · DOI
- Griffiths M, Coates C. In: Power engineering conference; 2007. p. 1–5. · DOI
- Vo, 2013, Int J Emerging Technol Adv Eng, 3, 536
- Cheng, 2009, IEEE Trans Ind Appl, 45, 805, 10.1109/TIA.2009.2013601 · DOI
- Savaghebi, 2013, IEEE Trans Ind Electron, 60, 1390, 10.1109/TIE.2012.2185914 · DOI
- Hamzeh, 2012, IEEE Trans Power Syst, 27, 2225, 10.1109/TPWRS.2012.2193906 · DOI
- Li, 2005, IEEE Trans Ind Appl, 41, 1707, 10.1109/TIA.2005.858262 · DOI
- Savaghebi, 2012, IEEE Trans Smart Grid, 3, 797, 10.1109/TSG.2011.2181432 · DOI
- Ngamroo, 2012, Electr Power Energy Syst, 43, 969, 10.1016/j.ijepes.2012.05.051 · DOI
- Wichert, 1997, Renew Sustain Energy Rev, 3, 209, 10.1016/S1364-0321(97)00006-3 · DOI
- Tan, 2013, Electr Power Energy Syst, 44, 179, 10.1016/j.ijepes.2012.07.015 · DOI
- Liu, 2012, Energy Procedia, 16, 1822, 10.1016/j.egypro.2012.01.280 · DOI
- Kim, 2004, IEEE Trans Power Electron, 19, 66, 10.1109/TPEL.2003.820559 · DOI
- Zhang, 2002, IEEE Trans Power Electron, 17, 314, 10.1109/TPEL.2002.1004239 · DOI
Cited by
Sorted by citations
Hannan, M. A., Ker, P. J., Lipu, M. S. H., Choi, Z. H., Rahman, M. S. A., Muttaqi, K. M., & Blaabjerg, F. (2020) · IEEE Access · doi:10.1109/access.2020.2967345 · Cited by 339
Metadata
- Authors
- Kim, G.-H., Hwang, C., Jeon, J.-H., Ahn, J.-B., & Kim, E.-S.
- Affiliations
- Korea Electrotechnology Research Institute (KR)
- Corresponding author
- Kim, Gyeong-Hun
- Venue
- International Journal of Electrical Power & Energy Systems
- Publisher
- Elsevier BV
- Published
- 2015-02
- Volume
- 65
- Pages
- 70-75
- ISSN
- 0142-0615 (ISSN-L)
- OpenAlex
- W2082593246
- Cited by
- 41
- References
- 0
- Citations by year
- 2026: 3 · 2025: 4 · 2024: 1 · 2023: 3 · 2022: 2 · 2021: 2 · 2020: 6 · 2019: 5 · 2018: 2 · 2017: 3 · 2016: 5 · 2015: 5
- FWCI
- 4.83
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- International Journal of Electrical Power & Energy Systems (publishedVersion, cc-by-nc-nd)
- Topics
- Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Power Quality and Harmonics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Keywords
- three-phase four-leg inverter, stand-alone microgrid, power quality, unbalanced loads, photovoltaic power generation, battery energy storage, diesel generator, power management system, microgrid stability, irradiance variation, control algorithms
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.