The DOI matches its Crossref record; 170 of the 170 references it cites were found in a registry or an index; 15 of the 85 sources its claims cite were checked for support.
State of the Art of Solid-State Transformers: Advanced Topologies, Implementation Issues, Recent Progress and Improvements
Open accessAbstract
Solid-state transformer (SST) is an emerging technology integrating with a transformer power electronics converters and control circuitry. This paper comprehensively reviews the SST topologies suitable for different voltage levels and with varied stages, their control operation, and different trends in applications. The paper discusses various SST configurations with their design and characteristics to convert the input to output under unipolar and bipolar operation. A comparison between the topologies, control operation and applications are included. Different control models and schemes are explained. Potential benefits of SST in many applications in terms of controllability and the synergy of AC and DC systems are highlighted to appreciate the importance of SST technologies. This review highlights many factors including existing issues and challenges and provides recommendations for the improvement of future SST configuration and development.
Overview
CoChat Summary
## TL;DR
This paper is a comprehensive review of solid-state transformers (SSTs), comparing topologies, control methods, implementation issues, and applications across smart grids, renewables, traction, microgrids, and more. It argues SSTs offer major advantages over low-frequency transformers, but cost, reliability, protection, insulation, and communication challenges still limit wide deployment.
## Key findings
- SSTs provide several benefits over low-frequency transformers, including reactive power compensation, voltage regulation, power flow control, voltage sag compensation, bi-directional power flow, fault current limiting, harmonic blocking, and galvanic isolation.
- The paper states that a 3-phase SST has 80% lesser volume than a low-frequency transformer, and notes a 97% efficiency single-stage AC-AC SST reported in 2017.
- Among topologies, the paper says three-stage SSTs are the most common and are superior to one-stage and two-stage designs for voltage regulation, current limiting, protection, and power factor, though they have lower efficiency because of more conversion stages.
- For medium-frequency converters, the paper reports DAB with SRC up to 98.61% efficiency, AQAB at 97.5%, and DAB at 92.5%; it also says AQAB can reduce system cost by approximately 20%.
## Methods
- Literature review of SST topologies, control operation, applications, and implementation challenges, organized into single-stage, two-stage, and three-stage configurations.
- Comparative synthesis of published designs and specifications, including MV SST designs from companies/research groups such as Siemens, Bombardier, Alstom, GE, UNIFLEX, ABB PETT, ETH, EPRI, Hubei Lab, ABB, and FREEDM.
- Analysis is mainly qualitative and comparative, supported by reported performance figures, tables, and prior studies rather than new experiments or a new dataset.
## Limitations
- The paper explicitly states that SSTs are still at the research and testing stage, with reliability challenges, and that long-term testing and research are required.
- It states SSTs are not yet economically justified and that cost remains high; for example, it notes a 100 kVA SST material cost is at least 5 times that of an equally rated LFT.
- It also says SSTs cannot yet be a direct replacement for LFTs in distribution grids because of protection and communication limitations, and because existing grids are not easily adapted.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
13 Valid · 3 Not valid · 69 Not checked · 52 Own results and interpretations
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Thus, it requires a bulky filter on the DC side which significantly increases the overall cost of MMC [24].”
§ State of the Art of Solid-State Transformers: Advanced Topologies, Implementation Issues, Recent Progress and Improvements > 1) MEDIUM VOLTAGE STAGE (AC TO DC)
What the sources say
- Partly supportedcites [24] 24. L. F. Costa, G. De Carne, G. Buticchi, and M. Liserre, ''The smart transformer: A solid-state transformer tailored to provide ancillary ser- vices to the distribution grid,'' IEEE Power Electron. Mag., vol. 4, no. 2, pp. 56-67, Jun. 2017. sourceExperimental — accuracy not yet measured
The “C. MV side” passage says the MMC requires a bulky DC-side filter compared with the CHB and has high cost. It does not say that the filter itself significantly increases the MMC’s overall cost. (LLM, conf=0.84)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“According to [74], the system cost could be reduced by approximately 20%.”
§ State of the Art of Solid-State Transformers: Advanced Topologies, Implementation Issues, Recent Progress and Improvements > 3) MEDIUM FREQUENCY CONVERTER
What the sources say
- Supportedcites [74] 74. L. F. Costa, F. Hoffmann, G. Buticchi, and M. Liserre, ''Comparative analysis of MAB dc-dc converters configurations in modular smart trans- former,'' in Proc. IEEE 8th Int. Symp. Power Electron. Distrib. Gener. Syst. (PEDG), Apr. 2017, pp. 1-8. source
Section E, “QAB vs. DAB,” states that adopting the AQAB architecture instead of the DAB architecture can reduce system cost by around 20%. The estimate is for the specifications in Table I when Si-IGBTs are used. (LLM, conf=0.94)
hedgedstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“The four-leg converter outperforms the conventional three-leg converters in terms of the degree of freedom and better control capability [72].”
§ State of the Art of Solid-State Transformers: Advanced Topologies, Implementation Issues, Recent Progress and Improvements > FIGURE 10.
What the sources say
- Partly supportedcites [72] 72. G.-H. Kim, C. Hwang, J.-H. Jeon, J.-B. Ahn, and E.-S. Kim, ''A novel three-phase four-leg inverter based load unbalance compensator for stand- alone microgrid,'' Int. J. Electr. Power Energy Syst., vol. 65, pp. 70-75, Feb. 2015. sourceExperimental — accuracy not yet measured
The Introduction (page unavailable) says three-phase three-wire generators cannot inject unbalanced current, while the proposed four-leg system compensates it. This supports a control advantage for unbalanced loads, but the paper does not state a general advantage in degrees of freedom or control capability over conventional three-leg converters. (LLM, conf=0.82)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
The cited sources that could be checked couldn’t confirm or dispute this claim.
In the paper
“The insulation failure caused by the high-frequency PWM waveform reduces the life cycle due to the accelerated aging, electrical stress, overvoltage, and heating [154].”
§ State of the Art of Solid-State Transformers: Advanced Topologies, Implementation Issues, Recent Progress and Improvements > D. ELECTRICAL INSULATION AND PARTIAL DISCHARGE
What the sources say
- Could not verifycites [154] 154. Y. Kikuchi, K. Yamashita, A. Kumada, K. Hidaka, K. Tatamidani, and T. Masuda, ''Partial discharge characteristics in composite insulation systems with PPLP for HTS cable,'' J. Phys. Conf. Ser., vol. 507, no. 3, May 2014, Art. no. 032024. sourceExperimental — accuracy not yet measured
The Introduction (page unavailable) discusses partial discharge in butt gaps degrading the insulation of HTS cables, and Materials and methods describes tests using 50 Hz AC voltage. Searches for high-frequency PWM and for life-cycle reduction through accelerated aging, overvoltage, or heating found no passage addressing the cited claim. (LLM, conf=0.76)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Could not verify
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“The works in [156] found that PD behaviour and insulation life are influenced by the voltage frequency.”
§ State of the Art of Solid-State Transformers: Advanced Topologies, Implementation Issues, Recent Progress and Improvements > D. ELECTRICAL INSULATION AND PARTIAL DISCHARGE
What the sources say
- Partly supportedcites [156] 156. R. Bodega, P. Morshuis, M. Lazzaroni, and F. Wester, ''PD recurrence in cavities at different energizing methods,'' IEEE Trans. Instrum. Meas., vol. 53, no. 2, pp. 251-258, Apr. 2004. sourceExperimental — accuracy not yet measured
The Introduction (page unavailable) says that PD behaviour in dielectric-bounded cavities can depend on voltage frequency. It also links PD activity to insulation aging, but does not establish that voltage frequency influences insulation life; that part of the claim is unsupported. (LLM, conf=0.87)
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
50 more claims
Create a free account to see all 137 claims and every source verdict.
- It may state two separate claims as one. 65
- Probably not a substantial claim. 25
Citations
Cites
Zhao, B., Song, Q., Liu, W., & Sun, Y. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2289913 · Cited by 1,886
The Future Renewable Electric Energy Delivery and Management (FREEDM) System: The Energy Internet
Huang, A. Q., Crow, M. L., Heydt, G. T., Zheng, J. P., & Dale, S. J. (2011) · Proceedings of the IEEE · doi:10.1109/jproc.2010.2081330 · Cited by 1,463 · cited 4×
“[13] developed a 15-kV SiC MOSFET-based single-phase SST topology.”
BackgroundMethodInfluentialMultilevel Converters: An Enabling Technology for High-Power Applications
Rodriguez, J., Franquelo, L. G., Kouro, S., Leon, J. I., Portillo, R. C., Prats, M. A. M., & Perez, M. A. (2009) · Proceedings of the IEEE · doi:10.1109/jproc.2009.2030235 · Cited by 1,196 · cited 1×
“8, which has the possibility of fault-tolerance implementation, multilevel operation, reduced rate of change of voltage, and filter size [64]–[66].”
BackgroundReview of Solid-State Transformer Technologies and Their Application in Power Distribution Systems
She, X., Huang, A. Q., & Burgos, R. (2013) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2013.2277917 · Cited by 1,164 · cited 3×
“Core-type has greater insulation between primary and secondary sides; shell-type could provide better mechanical protection; matrix-type has the multiple cores which have the capability for inter-wiring features that help to reduce leakage inductance and winding AC resistance [34], [94].”
BackgroundVoltage and Power Balance Control for a Cascaded H-Bridge Converter-Based Solid-State Transformer
Zhao, T., Wang, G., Bhattacharya, S., & Huang, A. Q. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2216549 · Cited by 642 · cited 2×
“The control strategies and balancing circuits are also required to prevent the problem in voltage and power balancing and that comes with drawbacks like complex systems in configuration and control scheme [17], [18].”
BackgroundMethodTeichmann, R., & Bernet, S. (2005) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2005.847285 · Cited by 578
Dynamic Behavior of the Doubly Fed Induction Generator During Three-Phase Voltage Dips
LÓpez, J., Sanchis, P., Roboam, X., & Marroyo, L. (2007) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2006.878241 · Cited by 550 · cited 1×
“Due to the PQ issues that were explained in [130], [131], and the stepping up of the voltage which requires a large conventional transformer that is unacceptable; accordingly, SST has a huge potential in wind as well related applications [65].”
BackgroundSilicon carbide benefits and advantages for power electronics circuits and systems
Elasser, A., & Chow, T. P. (2002) · Proceedings of the IEEE · doi:10.1109/jproc.2002.1021562 · Cited by 537 · cited 1×
“Hereafter comes with the SiC devices which are more efficient than Si devices [40], [42], [43].”
BackgroundMultilevel Converters: Fundamental Circuits and Systems
Akagi, H. (2017) · Proceedings of the IEEE · doi:10.1109/jproc.2017.2682105 · Cited by 513
Applicability of solid-state transformers in today's and future distribution grids
Huber, J. E., & Kolar, J. W. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2017.2738610 · Cited by 506 · cited 1×
“It is not easy to implement such adaptions in the existing distribution grids and would be costly to do so [159].”
Background
Research works printed but not linked: 3
- 2019, Lightning and Surge Protection for Intelligent Transformer Substations
- 10.1109/JESTPE.2016.2623794 · DOI · Paper page
- 2008, Soft ferritesferrite materials survey
Cited by
Soft Open Point in Distribution Networks
Fuad, K. S., Hafezi, H., Kauhaniemi, K., & Laaksonen, H. J. J. (2020) · IEEE Access · doi:10.1109/access.2020.3039552 · Cited by 114
A Comprehensive Review of Electric Vehicles Fast Charging Developments and Technology
Zentani, A. T., Almaktoof, A. M. A., & Kahn, M. (2024) · doi:10.20944/preprints202404.1355.v1 · Cited by 113
A Comprehensive Review of Developments in Electric Vehicles Fast Charging Technology
Zentani, A., Almaktoof, A., & Kahn, M. T. (2024) · Applied Sciences · doi:10.3390/app14114728 · Cited by 146
“…designs soft-switching used in Zeta, and , 14 , 4728 However, as the power requirements of DC fast chargers increase, the system’s output power can be enhanced by connecting multiple identical modules in parallel. transformer (HFT) can be incorporated within the DC-DC stage, as shown in…”
BackgroundTahir, Y., Khan, I., Rahman, S., Nadeem, M. F., Iqbal, A., Xu, Y., & Rafi, M. (2021) · IET Power Electronics · doi:10.1049/pel2.12141 · Cited by 107
Zand, M., Nasab, M. A., Padmanaban, S., Maroti, P. K., & Holm‐Nielsen, J. B. (2020) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2020.0399 · Cited by 90
Metadata
- Authors
- Hannan, M. A., Ker, P. J., Lipu, M. S. H., Choi, Z. H., Rahman, M. S. A., Muttaqi, K. M., & Blaabjerg, F.
- Affiliations
- Universiti Tenaga Nasional (MY)
- National University of Malaysia (MY)
- University of Wollongong (AU)
- Aalborg University (DK)
- ORCID
- Venue
- IEEE Access
- Published
- 2020
- Volume
- 8
- Pages
- 19113-19132
- ISSN
- 2169-3536 (ISSN-L)
- OpenAlex
- W3000015813
- Semantic Scholar
- aba467fe5fccf54319af02cf8278a2b335dee2c8
- Cited by
- 339
- References
- 162
- Citations by year
- 2026: 32 · 2025: 57 · 2024: 49 · 2023: 64 · 2022: 62 · 2021: 50 · 2020: 25
- FWCI
- 17.24
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- IEEE Access (publishedVersion, cc-by)
- VBN Forskningsportal (Aalborg Universitet) (publishedVersion, cc-by)
- Research Online (University of Wollongong) (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Figshare (submittedVersion, cc-by)
- Greater South Information System
- Funders
- Ministry of Higher Education, Malaysia (20190101LRGS)
- Universiti Tenaga Nasional (10436494/B/2019093)
- TNB for Seed Funding (U-TD-RD-19-20)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › HVDC Systems and Fault Protection
- Keywords
- solid-state transformer, power converters, transformer topology, control strategy, AC/DC power systems, AC/DC hybrid power system, power converter design
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-07, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-07 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: State of the Art of Solid-State Transformers: Advanced Topologies, Implementation Issues, Recent Progress and Improvements. https://app.cochat.ai/papers/10.1109/access.2020.2967345
- The paper
- Hannan, M. A., Ker, P. J., Lipu, M. S. H., Choi, Z. H., Rahman, M. S. A., Muttaqi, K. M., & Blaabjerg, F. (2020). State of the Art of Solid-State Transformers: Advanced Topologies, Implementation Issues, Recent Progress and Improvements. IEEE Access. https://doi.org/10.1109/access.2020.2967345
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.