Dynamic protection of power systems with high penetration of renewables: A review of the traveling wave based fault location techniques
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Abstract Governments set more ambitious goals about CO2 emission reductions and increasing the share of clean energy in the overall generation portfolio. A natural outcome of this trend is more deployment of renewables both at transmission and distribution networks. In addition to well-known environmental benefits, introduction of these non-conventional technologies changes the operation of power systems: e.g. reduced inertia, less stability and more unpredictability. Since most of these novel generation technologies are inverter-interfaced, their behavior under fault conditions are much different than conventional rotating machines. This creates novel challenges in power system protection. Accurate determination of location and type of a fault provides faster system restoration, increased reliability and cost benefits. There are various methods utilized for power system protection. Travelling wave-based fault location methods are preferred due to high accuracy and ultrafast detection capability. This paper reviews the latest developments in traveling wave-based fault location techniques. Signal processing methods hold a key role in information extraction since traveling wave transients have high frequency. A critical review of these methods reported in literature is presented. Application of travelling wave-based protection techniques is examined and special focus is given to distribution systems with high penetration of renewable energy-based generators. Traveling wave-based protection techniques have tremendous potential for future protection applications in smart grid scenarios viz. microgrids and active distribution systems. Being able to detect a fault under different current and voltage conditions make them a very strong candidate for achieving adaptive protection in power systems with high penetration of renewables. Finally, implementation of travelling wave-based fault location system based on IEC 61850 standard is also investigated. Having a standardized implementation is a solid step towards achieving plug-and-play (PnP) in dynamic power networks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Daubechies, I. (1992) · doi:10.1137/1.9781611970104 · Cited by 15,979
Development of a New Type Fault Locator Using the One-Terminal Voltage and Current Data
Takagi, T., Yamakoshi, Y., Yamaura, M., Kondow, R., & Matsushima, T. (1982) · IEEE Transactions on Power Apparatus and Systems · doi:10.1109/tpas.1982.317615 · Cited by 635
Cited by
Smart grids and renewable energy systems: Perspectives and grid integration challenges
Khalid, M. (2024) · Energy Strategy Reviews · doi:10.1016/j.esr.2024.101299 · Cited by 684
Tariq, R., Alhamrouni, I., Rehman, A. U., Tag Eldin, E., Shafiq, M., Ghamry, N. A., & Hamam, H. (2022) · Energies · doi:10.3390/en15176468 · Cited by 30
Netsanet, S., Zheng, D., Wei, Z., & Teshager, G. (2022) · Frontiers in Energy Research · doi:10.3389/fenrg.2022.826915 · Cited by 5
“…systems (Coffele et al., 2015; Singh et al., 2016), signal processing techniques (Bukhari et al., 2017; Netsanet et al., 2018; Wang et al., 2019; Aftab et al., 2020; Xie et al., 2020; Sharma et al., 2021; Wilches-Bernal et al., 2021), and machine learning tools (Orozco-Henao et al., 2018; Silva…”
Method
Metadata
- Authors
- Aftab, M. A., Hussain, S. M. S., Ali, I., & Ustun, T. S.
- Venue
- International Journal of Electrical Power & Energy Systems
- Publisher
- Elsevier BV
- Published
- 2020-01
- Volume
- 114
- Pages
- 105410
- ISSN
- 0142-0615 (ISSN-L)
- OpenAlex
- W2957542766
- Cited by
- 169
- References
- 2
- FWCI
- 9.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dynamic protection of power systems with high penetration of renewables: A review of the traveling wave based fault location techniques. https://app.cochat.ai/papers/10.1016/j.ijepes.2019.105410
- The paper
- Aftab, M. A., Hussain, S. M. S., Ali, I., & Ustun, T. S. (2020). Dynamic protection of power systems with high penetration of renewables: A review of the traveling wave based fault location techniques. International Journal of Electrical Power & Energy Systems. https://doi.org/10.1016/j.ijepes.2019.105410
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.