Cited by 9Microgrid Control and OptimizationPower System Optimization and StabilityWind Turbine Control Systems

The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.

An improved grid-forming control method with adaptive virtual impedance combining current limitation and transient stability improvement

Open access
Zhou, Xiaoping, Zhang, Lei, Peng, Hanting, Hong, Lerong, Xu, Qianming, Zhang, Zhen, Shao, Jiakun, Ma, Jianchao, Hu, Yizhen·2026·International Journal of Electrical Power & Energy Systems

Abstract

• Established large-signal model of grid forming converters with virtual impedance. • Provided effect analysis of grid and virtual impedance on transient stability. • Proposed an improved GFM control for current limitation and transient stability. • Designed corresponding coefficients of the control method quantitatively. • Validated the effectiveness through experiment prototype under various faults. The virtual impedance (VI) control method is widely used to limit fault current for grid-forming converter (GFMC). However, in this article, it is found that the VI deteriorates the transient synchronization stability of the GFMC under grid faults. To solve this problem, an improved grid-forming control method combining current limitation and transient stability improvement is proposed. By compensating the transient electromagnetic power, the power feedback of the active power control (APC) loop is changed from the real active power at the point of common coupling to the virtual active power on the converter-side during the fault period. Then, the detrimental impact of virtual resistance on transient stability can be reversed into a beneficial effect, thereby solving the contradiction between current limitation and transient stability. Besides, the transient damping power is feedbacked to adjust the active power reference, ensuring the transient stability under faulty weak grid scenario. Both of them are used as two extra degrees of freedom to eliminate the active power imbalance and jointly enhance the transient stability. Furthermore, an adaptive VI control is adopted to automatically tune the VI so that the fault current can be kept at maximum allowable value to support faulty grid. More importantly, the proposed method is not affected by the fault degree and grid strength. Simulations and experimental results validate the effectiveness of the proposed method.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ijepes.2026.111659

Cites

23 of 23 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Flagged first, then by citations

Research works printed but not linked: 3

  1. IEEE guide for planning DC links terminating at AC locations having low short-circuit capacities. IEEE Standard 1204-1997. Jan. 1997, 1–266.
  2. Sadeghkhani, 2018, Transient monitoring function-based fault detection for inverter-interfaced microgrids, IEEE Trans Smart Grid, 9, 2097
  3. IEEE Standard for interconnection and interoperability of distributed energy resources with associated electric power systems interfaces. IEEE Standard 1547.2-2023, May 2024; 1–291.

Cited by

Sorted by citations

Metadata

Authors
Zhou, X., Zhang, L., Peng, H., Hong, L., Xu, Q., Zhang, Z., Shao, J., Ma, J., & Hu, Y.
Affiliations
Hunan University (CN)
Corresponding author
Zhou, Xiaoping
Venue
International Journal of Electrical Power & Energy Systems
Publisher
Elsevier BV
Published
2026-02
Volume
175
Pages
111659
ISSN
0142-0615 (ISSN-L)
OpenAlex
W7128513009
Cited by
8
References
23
Citations by year
2026: 8
FWCI
20.39
Type
journal article
Language
en
Open access
Locations
International Journal of Electrical Power & Energy Systems (publishedVersion, cc-by-nc-nd)
Funders
  • National Natural Science Foundation of China (52377182, U2166602)
  • National Key Research and Development Program of China (2024YFB2409300)
Topics
  • Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Power System Optimization and Stability
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Wind Turbine Control Systems
Keywords
grid-forming inverters, virtual impedance, adaptive virtual impedance, transient stability, current limiting, fault current limitation, active power control, grid synchronization, virtual resistance

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review