FIGO consensus guidelines on intrapartum fetal monitoring: Intermittent auscultation
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Intermittent auscultation is the technique used to listen to the fetal heart rate (FHR) for short periods of time without a display of the resulting pattern. Whether it is used for intrapartum fetal monitoring in low-risk women or for all cases in settings where there are no available alternatives, all healthcare professionals attending labor and delivery need to be skilled at performing intermittent auscultation, interpreting its findings, and taking appropriate action. The main aim of this chapter is to describe the tools and techniques for intermittent auscultation in labor. Hippocrates is said to have described the technique of listening to the internal activity of the body by placing the ear on the skin proximal to the organ under examination. However, the perception of fetal heart sounds using this method was not reported until the 1600s [1]. Little attention appears to have been given to fetal heart auscultation until 1818, when it was discussed by both Mayor and de Kergaradec [2] to determine whether the fetus was alive or dead. Interest then accelerated, and in 1833 Kennedy published a book on the subject of obstetric auscultation [3]. The first recorded use of an amplification device for auscultation of the adult heart rate is attributed to Laënnec in 1816, who overcame the embarrassment of placing the ear on a young woman's chest to hear her heart beat by rolling sheets of paper into a tube and listening through this device [2]. This tool was soon replicated in wood, and gained wide usage for fetal heart auscultation. The most common instrument currently used for this purpose is the Pinard stethoscope (1, 2), but in some countries, notably the USA, the DeLee stethoscope is used as an alternative (Fig. 3). In both cases, the technology has not changed much from the original design, in which a belled tube creates an amplification chamber for sound waves that are transmitted from the fetal heart to the examiner's ear. A Pinard stethoscope. Pinard stethoscope in use. A DeLee stethoscope. More recently, handheld electronic devices that rely on the Doppler effect have been used for intermittent auscultation (Fig. 4), a technology similar to the external FHR monitoring of cardiotocography (CTG). However, as described in the chapter on CTG [4], these devices do not transmit the actual sound produced by the fetal heart, but rather a representation of this, based on ultrasound-detected movements of fetal cardiac structures, that are then subject to signal modification and autocorrelation. Table 1 compares the advantages and disadvantages of the three instruments currently used for intermittent auscultation. Handheld Doppler device. As for other approaches to fetal monitoring, the main aim of intermittent auscultation is the timely identification of fetuses with hypoxia/acidosis to enable appropriate action before the occurrence of injury. It also allows the confirmation of normal FHR characteristics, so that unnecessary intervention will be avoided. Systematic reviews of randomized controlled trials carried out in the 1970s, 1980s, and early 1990s, comparing intermittent auscultation with continuous CTG for intrapartum monitoring in both low- and high-risk women, have shown that CTG is associated with a lower risk of neonatal seizures, but with higher cesarean and instrumental vaginal delivery rates [5]. The limitations of this evidence are analyzed in the chapter on CTG [4]. There is currently no conclusive evidence for the benefits of continuous CTG versus intermittent auscultation monitoring in labor. There are also no trials comparing intermittent auscultation with no FHR auscultation during labor. Based on expert opinion, intermittent auscultation should be recommended in all labors in settings where there is no access to CTG monitors or to the resources necessary for using them. When the resources for CTG monitoring are available, intermittent auscultation may be used for routine intrapartum monitoring in low-risk cases (Table 2). However, approximately half of the panel members believe that continuous CTG should be the option during the second stage of labor, although there is no direct scientific evidence to support this. Performing regular intermittent auscultation ensures frequent contact between healthcare professionals and the laboring woman, offering the opportunity for social and clinical support. It facilitates the assessment of other physical parameters such as maternal skin tone, temperature, breathing patterns, direct palpation of fetal movements, and maternal contractions. Intermittent auscultation permits the fetal heart to be monitored in various positions and locations and favors the mobility of laboring women, which has been shown to benefit the progress of labor [7]. Another benefit of intermittent auscultation is the easier availability and sustainability of the technology, which allows it to be undertaken in even the lowest resource settings. It takes time to develop clinical expe
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
FIGO consensus guidelines on intrapartum fetal monitoring: Cardiotocography
Ayres‐de‐Campos, D., Spong, C. Y., Chandraharan, E., & Panel, F. I. F. M. E. C. (2015) · International Journal of Gynecology & Obstetrics · doi:10.1016/j.ijgo.2015.06.020 · Cited by 911
Self-citation
Cited by
Escuriet, R., García-Lausin, L., Salgado-Poveda, I., Casañas, R., Robleda, G., Canet, O., Pérez-Botella, M., Frith, L., Daly, D., & Pueyo, M. (2017) · European Journal of Midwifery · doi:10.18332/ejm/76820 · Cited by 2,251
Stillbirths: ending preventable deaths by 2030
de Bernis, L., Kinney, M. V., Stones, W., ten Hoope-Bender, P., Vivio, D., Leisher, S. H., Bhutta, Z. A., Gülmezoglu, M., Mathai, M., Belizán, J. M., et al. (2016) · The Lancet · doi:10.1016/s0140-6736(15)00954-x · Cited by 473
ACOG Committee Opinion No. 766: Approaches to Limit Intervention During Labor and Birth
(2019) · Obstetrics & Gynecology · doi:10.1097/aog.0000000000003074 · Cited by 197
Housseine, N., Punt, M. C., Browne, J. L., Meguid, T., Klipstein-Grobusch, K., Kwast, B. E., Franx, A., Grobbee, D. E., & Rijken, M. J. (2018) · PLOS ONE · doi:10.1371/journal.pone.0206295 · Cited by 45
Mdoe, P. F., Ersdal, H. L., Mduma, E. R., Perlman, J. M., Moshiro, R., Wangwe, P. T., & Kidanto, H. (2018) · BMC Pregnancy and Childbirth · doi:10.1186/s12884-018-1746-9 · Cited by 43
Metadata
- Authors
- Lewis, D., Downe, S., & Panel, F. I. F. M. E. C.
- Venue
- International Journal of Gynecology & Obstetrics
- Publisher
- Wiley
- Published
- 2015-09-30
- Volume
- 131
- Issue
- 1
- Pages
- 9-12
- ISSN
- 0020-6695 (ISSN-L)
- 0020-7292
- 1879-3479
- OpenAlex
- W1910309054
- Cited by
- 119
- References
- 1
- FWCI
- 10.37
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: FIGO consensus guidelines on intrapartum fetal monitoring: Intermittent auscultation. https://app.cochat.ai/papers/10.1016/j.ijgo.2015.06.019
- The paper
- Lewis, D., Downe, S., & Panel, F. I. F. M. E. C. (2015). FIGO consensus guidelines on intrapartum fetal monitoring: Intermittent auscultation. International Journal of Gynecology & Obstetrics. https://doi.org/10.1016/j.ijgo.2015.06.019
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.