Effect of microstructure on melting in metal-foam/paraffin composite phase change materials
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The performance of phase change materials (PCM) as energy storage units are often limited by their low thermal conductivities that constrain the rates of melting or solidification. Highly porous metal foam composite PCMs are increasingly being used to abate this limitation and enable greater control over the thermal and phase change characteristics of the system. In the present study, a pore-scale computational analysis is carried out to characterize the performance of an n-eicosane-aluminium-foam composite PCM with a porosity of 0.94, over varying microstructural properties including strut, pore and cell sizes, and specific surface area. The simulations are carried out using OpenFOAM by employing the enthalpy-porosity formulation for modeling phase change during melting. The foam geometries are generated computationally using tools developed by the authors, published recently (Abishek et al., 2017, Ref. [1]). The statistics of the pore-scale structures of the virtual foam geometries and the numerical methodology employed for the modeling were validated against theoretical and empirical data from the literature. The simulations reveal that the presence of metal foam significantly enhances the melting rate as compared to pure PCM. It is also found that the melting rates are strongly correlated to the specific surface of the foam – highlighting a vital parameter that can be used to optimize the performance of the composite PCM for a given application. An empirical relationship correlating the dimensionless melt fraction with the Fourier number, Stefan number and dimensionless specific surface area is also presented for the range of parameters considered in this study.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Melting and Solidification of a Pure Metal on a Vertical Wall
Gau, C., & Viskanta, R. (1986) · Journal of Heat Transfer · doi:10.1115/1.3246884 · Cited by 655
Experimental studies on the applications of PCMs and nano-PCMs in buildings: A critical review
Kasaeian, A., bahrami, L., Pourfayaz, F., Khodabandeh, E., & Yan, W.-M. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2017.08.037 · Cited by 287
Cited by
Thermal conductivity enhancement on phase change materials for thermal energy storage: A review
Wu, S., Yan, T., Kuai, Z., & Pan, W. (2020) · Energy Storage Materials · doi:10.1016/j.ensm.2019.10.010 · Cited by 962
Role of porous metal foam on the heat transfer enhancement for a thermal energy storage tube
Yang, X., Yu, J., Guo, Z., Jin, L., & He, Y.-L. (2019) · Applied Energy · doi:10.1016/j.apenergy.2019.01.075 · Cited by 257
Qureshi, Z. A., Al-Omari, S. A. B., Elnajjar, E., Al-Ketan, O., & Al-Rub, R. A. (2021) · International Communications in Heat and Mass Transfer · doi:10.1016/j.icheatmasstransfer.2021.105265 · Cited by 189
Nassar, A., Nassar, E., Rivilla, I., Labidi, J., Fernández, A. G., Sarasini, F., Abu El Fadl, A., & Younis, M. (2024) · Results in Engineering · doi:10.1016/j.rineng.2024.101885 · Cited by 64
Metadata
- Authors
- Abishek, S., King, A. J. C., Nadim, N., & Mullins, B. J.
- Venue
- International Journal of Heat and Mass Transfer
- Publisher
- Elsevier BV
- Published
- 2018-12
- Volume
- 127
- Pages
- 135-144
- ISSN
- 0017-9310 (ISSN-L)
- OpenAlex
- W2884482790
- Cited by
- 90
- References
- 2
- FWCI
- 6.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.