Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 230

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Thermal performance of cylindrical Lithium-ion battery thermal management system based on air distribution pipe

Zhou, Haobing, Zhou, Fei, Xu, Lipeng, Kong, Jizhou, QingxinYang · 2019 · International Journal of Heat and Mass Transfer

Abstract

Abstract For a typical air cooling thermal management system, the inlet and outlet of air flow on both sides of the battery module would increase the temperature difference. In here, a novel cooling strategy based on air distribution pipes is proposed for the cylindrical Lithium-ion battery module. The three-dimensional computational fluid dynamics model of battery module is constructed and validated by the experimental tests. The thermal behavior of battery module and the flow field of air have been explored using numerical simulations at different discharge rates, and then the effects of orifice parameters, inlet pressure and discharge rate on the performance of air cooling strategy have been analyzed. The results show that the maximum temperature of the battery module can be effectively reduced by the increase of inlet pressure resulting in a significant rise of power consumption. Meanwhile, it declines when the diameter and number of rows of the orifice increase, following a minor rise in power consumption. When the inlet pressure is 100 Pa, the diameter of the orifice is 1.5 mm, the number of rows of the orifice is 5 and the discharge rate is 3C, the maximum temperature of battery module decreases from 325.9 K to 305.7 K in comparison to that under none air cooling condition. In addition, the maximum temperature difference of battery module is within 3 K. When the battery module discharge at the current rate of 4C and 5C, the maximum temperature of battery module maintains within 313.15 K, but the temperature difference slightly exceeds the optimal range at 5C discharge when the inlet pressure is 200 Pa, the diameter of the orifice is 1.5 mm and the number of rows of the orifice is 5. Moreover, it is an efficient and a practical cooling strategy with no need to modify the arrangement of the battery module.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ijheatmasstransfer.2018.11.116

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 230

Metadata

Authors
Zhou, H., Zhou, F., Xu, L., Kong, J., & QingxinYang
Venue
International Journal of Heat and Mass Transfer
Publisher
Elsevier BV
Published
2019-03
Volume
131
Pages
984-998
ISSN
0017-9310 (ISSN-L)
OpenAlex
W2903551325
Cited by
230
References
3
FWCI
8.15
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Thermal performance of cylindrical Lithium-ion battery thermal management system based on air distribution pipe. https://app.cochat.ai/papers/10.1016/j.ijheatmasstransfer.2018.11.116
The paper
Zhou, H., Zhou, F., Xu, L., Kong, J., & QingxinYang. (2019). Thermal performance of cylindrical Lithium-ion battery thermal management system based on air distribution pipe. International Journal of Heat and Mass Transfer. https://doi.org/10.1016/j.ijheatmasstransfer.2018.11.116

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.