Geothermal energy use in hydrogen liquefaction
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Employing geothermal power in the ACC reduces the power required for H2 liquefaction and is more advantageous than using geothermal power output in a liquefaction process.
“It was found that employing geothermal power in the ACC reduces the power required for H2 liquefaction and is more advantageous than using geothermal power output in a liquefaction process.260”
From Strategies To Improve the Performance of Hydrogen Storage Systems by Liquefaction Methods: A Comprehensive Review (2023) · cites this paper as [260]
No citation lists for this paper
No citation lists for this paper yet — checked again daily.
References 15 · Cited by 84
- Authors
- KANOGLU, M., DINCER, I., & ROSEN, M.
- Affiliations
- Ontario Tech University (CA)
- ORCID
- ROSEN, M
- Venue
- International Journal of Hydrogen Energy
- Publisher
- Elsevier BV
- Published
- 2007-12
- Volume
- 32
- Issue
- 17
- Pages
- 4250-4257
- ISSN
- 0360-3199 (ISSN-L)
- OpenAlex
- W2016042461
- Cited by
- 84
- References
- 15
- Citations by year
- 2026: 4 · 2025: 7 · 2024: 3 · 2023: 8 · 2022: 5 · 2021: 4 · 2020: 2 · 2019: 2 · 2018: 7 · 2017: 8 · 2016: 5 · 2015: 2 · 2014: 4 · 2012: 7
- FWCI
- 8.41
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- International Journal of Hydrogen Energy (publishedVersion)
- Funders
- University of Ontario Institute of Technology
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Thermodynamic and Exergetic Analyses of Power and Cooling Systems
- Physical Sciences › Energy › Renewable Energy, Sustainability and the Environment › Geothermal Energy Systems and Applications
- Physical Sciences › Engineering › Mechanical Engineering › Advanced Thermodynamic Systems and Engines
- Keywords
- geothermal energy, hydrogen liquefaction, absorption refrigeration, Linde-Hampson cycle, combined heat and power, binary geothermal power plant, energy conservation, geothermal water temperature, irreversibility, performance parameters
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review