Cited by 142Spacecraft and Cryogenic TechnologiesThermodynamic and Exergetic Analyses of Power and Cooling SystemsHeat Transfer and Optimization

Reducing the exergy destruction in the cryogenic heat exchangers of hydrogen liquefaction processes

Open access
Wilhelmsen, Øivind, Berstad, David, Aasen, Ailo, Nekså, Petter, Skaugen, Geir·2018·International Journal of Hydrogen Energy

Integrity signals

Registry

Crossref · 10.1016/j.ijhydene.2018.01.094

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Theoretically, the minimum work required for hydrogen liquefaction is 2.7 kWh_el/kg-H2 at a feed pressure of 2.5 MPa.

    “Theoretically, the minimum work required for hydrogen liquefaction is 2.7 kWh el /kg-H 2 at a feed pressure of 2.5 MPa [94].”

    From 5917. https://doi.org/10.3390/en14185917. - (2021) · cites this paper as [94]

  • In practical applications, the specific energy demand for hydrogen liquefaction is approximately 10 kWh_el/kg-H2, although it is predicted that the demand can be reduced to approximately 6 kWh_el/kg-H2 with further process improvements.

    “However, in practical applications, the specific energy demand for hydrogen liquefaction is approximately 10 kWh el /kg-H 2 , although it is predicted that the demand can be reduced to approximately 6 kWh el /kg-H 2 with further process improvements [37,94].”

    From 5917. https://doi.org/10.3390/en14185917. - (2021) · cites this paper as [94]

  • According to the international demand for pure oxygen, LN2 will not be available as an inexpensive refrigerant for large-scale H2 liquefaction plants in the future.

    “According to the international demand for pure oxygen, LN2 will not be available as an inexpensive refrigerant for large-scale H2 liquefaction plants in the future.184”
  • Several mixed refrigerants have been developed with various precooling temperatures because the boiling point of the mixture depends on the composition.

    “Several mixed refrigerants have been developed with various precooling temperatures because the boiling point of the mixture depends on the composition.80,184”

No citation lists for this paper

No citation lists for this paper yet — checked again daily.

References 37 · Cited by 142

Authors
Wilhelmsen, Ø., Berstad, D., Aasen, A., Nekså, P., & Skaugen, G.
Affiliations
  • Norwegian University of Science and Technology (NO)
  • SINTEF Energy Research (NO)
Corresponding author
Wilhelmsen, Øivind
Venue
International Journal of Hydrogen Energy
Publisher
Elsevier BV
Published
2018-03
Volume
43
Issue
10
Pages
5033-5047
ISSN
0360-3199 (ISSN-L)
OpenAlex
W2789589713
Cited by
142
References
37
Citations by year
2026: 14 · 2025: 27 · 2024: 32 · 2023: 18 · 2022: 14 · 2021: 12 · 2020: 14 · 2019: 9 · 2018: 2
FWCI
7.52
Type
journal article
Language
en
Open access
Locations
  • International Journal of Hydrogen Energy (publishedVersion)
  • NORA - Norwegian Open Research Archives (submittedVersion, cc-by-nc-nd)
Funders
  • Statoil
  • Shell
  • Kawasaki Heavy Industries
  • Linde Kryotechnik
  • Mitsubishi Corporation
  • Nel Hydrogen
  • Research Council of Norway (255107/E20)
Topics
  • Physical Sciences › Engineering › Aerospace Engineering › Spacecraft and Cryogenic Technologies
  • Physical Sciences › Engineering › Mechanical Engineering › Thermodynamic and Exergetic Analyses of Power and Cooling Systems
  • Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
Keywords
hydrogen liquefaction, cryogenic heat exchangers, exergy destruction, plate-fin heat exchanger, ortho-para hydrogen conversion, catalytic isomerization, ferric oxide catalyst, temperature gradient, pressure drop, power consumption

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review