The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Technico-economic analysis of off grid solar PV/Fuel cell energy system for residential community in desert region
Abstract
A technico-economic analysis based on integrated modeling, simulation, and optimization approach is used in this study to design an off grid hybrid solar PV/Fuel Cell power system. The main objective is to optimize the design and develop dispatch control strategies of the standalone hybrid renewable power system to meet the desired electric load of a residential community located in a desert region. The effects of temperature and dust accumulation on the solar PV panels on the design and performance of the hybrid power system in a desert region is investigated. The goal of the proposed off-grid hybrid renewable energy system is to increase the penetration of renewable energy in the energy mix, reduce the greenhouse gas emissions from fossil fuel combustion, and lower the cost of energy from the power systems. Simulation, modeling, optimization and dispatch control strategies were used in this study to determine the performance and the cost of the proposed hybrid renewable power system. The simulation results show that the distributed power generation using solar PV and Fuel Cell energy systems integrated with an electrolyzer for hydrogen production and using cycle charging dispatch control strategy (the fuel cell will operate to meet the AC primary load and the surplus of electrical power is used to run the electrolyzer) offers the best performance. The hybrid power system was designed to meet the energy demand of 4500 kWh/day of the residential community (150 houses). The total power production from the distributed hybrid energy system was 52% from the solar PV, and 48% from the fuel cell. From the total electricity generated from the photovoltaic hydrogen fuel cell hybrid system, 80.70% is used to meet all the AC load of the residential community with negligible unmet AC primary load (0.08%), 14.08% is the input DC power for the electrolyzer for hydrogen production, 3.30% are the losses in the DC/AC inverter, and 1.84% is the excess power (dumped energy). The proposed off-grid hybrid renewable power system has 40.2% renewable fraction, is economically viable with a levelized cost of energy of 145 $/MWh and is environmentally friendly (zero carbon dioxide emissions during the electricity generation from the solar PV and Fuel Cell hybrid power system).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Micropower System Modeling with Homer
Lambert, T., Gilman, P., & Lilienthal, P. (2005) · Integration of Alternative Sources of Energy · doi:10.1002/0471755621.ch15 · Cited by 807
Integration of Alternative Sources of Energy
(2005) · Integration of Alternative Sources of Energy · doi:10.1002/0471755621.ch12 · Cited by 675
Off-grid electricity generation with renewable energy technologies in India: An application of HOMER
Sen, R., & Bhattacharyya, S. C. (2014) · Renewable Energy · doi:10.1016/j.renene.2013.07.028 · Cited by 617
Energy Management and Control System for Laboratory Scale Microgrid Based Wind-PV-Battery
Merabet, A., Tawfique Ahmed, K., Ibrahim, H., Beguenane, R., & Ghias, A. M. Y. M. (2017) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2016.2587828 · Cited by 433
Self-citationOptimal sizing of hybrid PV/diesel/battery in ship power system
Lan, H., Wen, S., Hong, Y.-Y., Yu, D. C., & Zhang, L. (2015) · Applied Energy · doi:10.1016/j.apenergy.2015.08.031 · Cited by 413
Castañeda, M., Cano-Ortega, A., Jurado, F., Sánchez–Sainz, H., & RAMIREZ, L. M. F. (2013) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2013.01.080 · Cited by 277
Modeling, simulation and experimental set-up of a renewable hydrogen-based domestic microgrid
Valverde, L., Rosa, F., del Real, A. J., Arce, A., & Bordons, C. (2013) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2013.06.113 · Cited by 149
Grid-tied and stand-alone hybrid solar power system for desalination plant
Ghenaï, C., Merabet, A., Salameh, T. S. Z., & Pigem, E. C. (2017) · Desalination · doi:10.1016/j.desal.2017.10.044 · Cited by 129
Self-citationEnergy Management Strategies in hydrogen Smart-Grids: A laboratory experience
Valverde, L., Rosa, F., Bordons, C., et al. (2016) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2016.05.279 · Cited by 107
Design of Solar-Biomass Hybrid Microgrid System in Sharjah
Ghenaï, C., & Janajreh, I. (2016) · Energy Procedia · doi:10.1016/j.egypro.2016.11.299 · Cited by 84
Cited by
Farghali, M., Osman, A. I., Chen, Z., Abdelhaleem, A., Ihara, I., Mohamed, I. M. A., Yap, P.-S., & Rooney, D. W. (2023) · Environmental Chemistry Letters · doi:10.1007/s10311-023-01587-1 · Cited by 361
Jamshidi, M., & Askarzadeh, A. (2019) · Sustainable Cities and Society · doi:10.1016/j.scs.2018.10.021 · Cited by 274
Güven, A. F., Yörükeren, N., & Samy, M. M. (2022) · Energy · doi:10.1016/j.energy.2022.124089 · Cited by 264
Maestre, V. M., Ortiz, A., & Ortiz, I. (2021) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2021.111628 · Cited by 254
Das, H. S., Salem, M., Zainuri, M. A. A. M., Dobi, A. M., Li, S., & Ullah, M. H. (2022) · Energy Reports · doi:10.1016/j.egyr.2022.10.407 · Cited by 32
Metadata
- Authors
- Ghenai, C., Salameh, T., & Merabet, A.
- Venue
- International Journal of Hydrogen Energy
- Publisher
- Elsevier BV
- Published
- 2020-04
- Volume
- 45
- Issue
- 20
- Pages
- 11460-11470
- ISSN
- 0360-3199 (ISSN-L)
- OpenAlex
- W2808927273
- Cited by
- 370
- References
- 13
- FWCI
- 11.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Technico-economic analysis of off grid solar PV/Fuel cell energy system for residential community in desert region. https://app.cochat.ai/papers/10.1016/j.ijhydene.2018.05.110
- The paper
- Ghenai, C., Salameh, T., & Merabet, A. (2020). Technico-economic analysis of off grid solar PV/Fuel cell energy system for residential community in desert region. International Journal of Hydrogen Energy. https://doi.org/10.1016/j.ijhydene.2018.05.110
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.