The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Next-generation anion exchange membrane water electrolyzers operating for commercially relevant lifetimes
Open accessAbstract
Abstract Alkaline anion exchange membrane (AEM) water electrolysis has gained increasing attention due to its potential to achieve low-cost, high performance hydrogen production. However, most existing membranes are not durable in industrial settings. Here, we demonstrate good performance relative to industrial parameters using Sustainion® anion exchange membranes. Long-duration tests showed stable performance of 1 A/cm2 at 1.85 V with a degradation rate of less than 1 μV/h over 10,000 h. The projected lifetime is thus over 20 years. Daily on/off cycling performance over the course of 30 years was simulated experimentally through accelerated voltage shock tests, resulting in a performance loss of only 0.15 μV/cycle over 11,000 cycles. As shown through impact and crossover testing, an improvement in performance is achieved by the addition of zirconia to the polymer matrix and mechanically reinforcing the membrane.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A comprehensive review on PEM water electrolysis
Carmo, M., Fritz, D. L., Mergel, J., & Stolten, D. (2013) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2013.01.151 · Cited by 5,492
Miller, H. A., Bouzek, K., Hnat, J., Loos, S., Bernäcker, C. I., Weißgärber, T., Röntzsch, L., & Meier-Haack, J. (2020) · Sustainable Energy & Fuels · doi:10.1039/c9se01240k · Cited by 785
Solid-State Water Electrolysis with an Alkaline Membrane
Leng, Y., Chen, G., Mendoza, A. J., Tighe, T. B., Hickner, M. A., & Wang, C.-Y. (2012) · Journal of the American Chemical Society · doi:10.1021/ja302439z · Cited by 543
Anion exchange membranes: Current status and moving forward
Hickner, M. A., Herring, A. M., & Coughlin, E. B. (2013) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/polb.23395 · Cited by 423
A Roadmap to Low‐Cost Hydrogen with Hydroxide Exchange Membrane Electrolyzers
Abbasi, R., Setzler, B. P., Lin, S., Wang, J., Zhao, Y., Xu, H., Pivovar, B., Tian, B., Chen, X., Wu, G., et al. (2019) · Advanced Materials · doi:10.1002/adma.201805876 · Cited by 340
First implementation of alkaline polymer electrolyte water electrolysis working only with pure water
Xiao, L., Zhang, S., Pan, J., Yang, C., He, M., Zhuang, L., & Lu, J. (2012) · Energy & Environmental Science · doi:10.1039/c2ee22146b · Cited by 313
Carbon Dioxide and Water Electrolysis Using New Alkaline Stable Anion Membranes
Kaczur, J. J., Yang, H., Liu, Z., Sajjad, S. D., & Masel, R. I. (2018) · Frontiers in Chemistry · doi:10.3389/fchem.2018.00263 · Cited by 275
Self-citationAnion Exchange Membranes’ Evolution toward High Hydroxide Ion Conductivity and Alkaline Resiliency
Arges, C. G., & Zhang, L. (2018) · ACS Applied Energy Materials · doi:10.1021/acsaem.8b00387 · Cited by 272
The effect of membrane on an alkaline water electrolyzer
Liu, Z., Sajjad, S. D., Gao, Y., Yang, H., Kaczur, J. J., & Masel, R. I. (2017) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2017.10.050 · Cited by 250
Self-citationHigh-performance alkaline water electrolysis using Aemion™ anion exchange membranes
Fortin, P., Khoza, T., Cao, X., Martinsen, S. Y., Oyarce Barnett, A., & Holdcroft, S. (2020) · Journal of Power Sources · doi:10.1016/j.jpowsour.2020.227814 · Cited by 238
Liu, D., & Case, S. W. (2006) · Journal of Power Sources · doi:10.1016/j.jpowsour.2006.07.007 · Cited by 218
Choe, Y.-K., Fujimoto, C., Lee, K.-S., Dalton, L. T., Ayers, K., Henson, N. J., & Kim, Y. S. (2014) · Chemistry of Materials · doi:10.1021/cm502422h · Cited by 195
Fu, R., Woo, J., Seo, S., Lee, J., & Moon, S. (2008) · Journal of Power Sources · doi:10.1016/j.jpowsour.2007.12.118 · Cited by 91
Imidazolium-based organic–inorganic hybrid anion exchange membranes for fuel cell applications
Feng, T., Lin, B., Zhang, S., Yuan, N., Chu, F., Hickner, M. A., Wang, C., Zhu, L. J., & Ding, J. (2016) · Journal of Membrane Science · doi:10.1016/j.memsci.2016.02.019 · Cited by 89
Li, X. H., Tao, J., Nie, G., Wang, L., Li, L., & Liao, S. (2014) · RSC Advances · doi:10.1039/c4ra06519k · Cited by 57
Padungthon, S., Li, J., German, M., & SenGupta, A. K. (2014) · Environmental Engineering Science · doi:10.1089/ees.2013.0412 · Cited by 46
Influence of trace oxygen in low-crossover proton exchange membrane fuel cells
Brooker, P., Rodgers, M. P., Bonville, L. J., Kunz, H. R., Slattery, D. K., & Fenton, J. M. (2012) · Journal of Power Sources · doi:10.1016/j.jpowsour.2012.06.089 · Cited by 10
Cited by
Chatenet, M., Pollet, B. G., Dekel, D. R., Dionigi, F., Deseure, J., Millet, P., Braatz, R. D., Bazant, M. Z., Eikerling, M., Staffell, I., et al. (2022) · Chemical Society Reviews · doi:10.1039/d0cs01079k · Cited by 2,025
Anion-Exchange Membrane Water Electrolyzers
Du, N., Roy, C., Peach, R., Turnbull, M., Thiele, S., & Bock, C. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00854 · Cited by 1,075
Durability of anion exchange membrane water electrolyzers
Li, D., Motz, A. R., Bae, C., Fujimoto, C., Yang, G., Zhang, F.-Y., Ayers, K. E., & Kim, Y. S. (2021) · Energy & Environmental Science · doi:10.1039/d0ee04086j · Cited by 601
Anion-exchange membrane water electrolyzers and fuel cells
Yang, Y., Li, P., Zheng, X., Sun, W., Dou, S. X., Ma, T., & Pan, H. (2022) · Chemical Society Reviews · doi:10.1039/d2cs00038e · Cited by 575
Chen, N., Paek, S. Y., Lee, J. Y., Park, J. H., Lee, S. Y., & Lee, Y. M. (2021) · Energy & Environmental Science · doi:10.1039/d1ee02642a · Cited by 417
Metadata
- Authors
- Motealleh, B., Liu, Z., Masel, R. I., Sculley, J. P., Richard Ni, Z., & Meroueh, L.
- Venue
- International Journal of Hydrogen Energy
- Publisher
- Elsevier BV
- Published
- 2021-01
- Volume
- 46
- Issue
- 5
- Pages
- 3379-3386
- ISSN
- 0360-3199 (ISSN-L)
- OpenAlex
- W3110933694
- Cited by
- 264
- References
- 17
- FWCI
- 8.95
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.