CoChat

Implementation of computerized provider order entry in a neonatal intensive care unit: Impact on admission workflow

Chapman, Alison K., Lehmann, Christoph U., Donohue, Pamela K., Aucott, Susan W. · 2012 · International Journal of Medical Informatics
Cited by 27

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

OBJECTIVE The study objective was to determine if computerized provider order entry (CPOE) systems impaired or enhanced workflow in the neonatal intensive care unit (NICU) by comparing the timing of administration of the first dose of antibiotics before and after CPOE system implementation. METHODS We conducted a pre-post intervention comparative study of the length of time between admission and administration of initial antibiotics in neonates before and after a CPOE system was implemented. Clinical information and timing of antibiotic administration were collected on all inborn infants, who were admitted to the NICU in the first 4h of life and treated with antibiotics, for one year prior to the implementation of computerized order entry and for one year after the implementation. RESULTS Infants admitted to the NICU were similar in both periods (mean birth weight 2183 g vs. 2091 g, gestational age 33.3 weeks vs. 33.0 weeks). There was no significant difference in mean length of time from admission to antibiotic administration in the pre-CPOE group (131 min [CI 124-139]) compared to the post-CPOE group (125 min [CI 116-133]) (p=0.07). The mean time to pharmacy verification for a subset of patients was significantly shorter for patients in the post-CPOE group (61 ± 58 min) compared to the pre-CPOE group (88 ± 76 min) (p=<0.001). CONCLUSIONS While the introduction of a CPOE system in the NICU did not significantly improve antibiotic administration times, the timeliness of an important aspect of the medication process, time to pharmacy verification, was improved. These findings imply other factors are impeding workflow. Further studies are needed to evaluate how CPOE systems combined with patient care activities affect workflow and overall patient care.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ijmedinf.2011.12.006

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 27

Metadata

Authors
Chapman, A. K., Lehmann, C. U., Donohue, P. K., & Aucott, S. W.
Venue
International Journal of Medical Informatics
Publisher
Elsevier BV
Published
2012-05
Volume
81
Issue
5
Pages
291-295
ISSN
1386-5056 (ISSN-L)
OpenAlex
W1993132224
Cited by
27
References
4
FWCI
5.61
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Implementation of computerized provider order entry in a neonatal intensive care unit: Impact on admission workflow. https://app.cochat.ai/papers/10.1016/j.ijmedinf.2011.12.006
The paper
Chapman, A. K., Lehmann, C. U., Donohue, P. K., & Aucott, S. W. (2012). Implementation of computerized provider order entry in a neonatal intensive care unit: Impact on admission workflow. International Journal of Medical Informatics. https://doi.org/10.1016/j.ijmedinf.2011.12.006

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.