Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 170

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

The development an artificial intelligence algorithm for early sepsis diagnosis in the intensive care unit

Open access
Yuan, Kuo-Ching, Tsai, Lung-Wen, Lee, Ko-Han, Cheng, Yi-Wei, Hsu, Shou-Chieh, Lo, Yu-Sheng, Chen, Ray-Jade · 2020 · International Journal of Medical Informatics

Abstract

BACKGROUND: Severe sepsis and septic shock are still the leading causes of death in Intensive Care Units (ICUs), and timely diagnosis is crucial for treatment outcomes. The progression of electronic medical records (EMR) offers the possibility of storing a large quantity of clinical data that can facilitate the development of artificial intelligence (AI) in medicine. However, several difficulties, such as poor structure and heterogenicity of the raw EMR data, are encountered when introducing AI with ICU data. Labor-intensive work, including manual data entry, personal medical records sorting, and laboratory results interpretation may hinder the progress of AI. In this article, we introduce the developing of an AI algorithm designed for sepsis diagnosis using pre-selected features; and compare the performance of the AI algorithm with SOFA score based diagnostic method. MATERIALS AND METHODS: This is a prospective open-label cohort study. A specialized EMR, named TED_ICU, was implemented for continuous data recording. One hundred six clinical features relevant to sepsis diagnosis were selected prospectively. A labeling work to allocate SEPSIS or NON_SEPSIS status for each ICU patient was performed by the in-charge intensivist according to SEPSIS-3 criteria, along with the automatic recording of selected features every day by TED_ICU. Afterward, we use de-identified data to develop the AI algorithm. Several machine learning methods were evaluated using 5-fold cross-validation, and XGBoost, a decision-tree based algorithm was adopted for our AI algorithm development due to best performance. RESULTS: The study was conducted between August 2018 and December 2018 for the first stage of analysis. We collected 1588 instances, including 444 SEPSIS and 1144 NON-SEPSIS, from 434 patients. The 434 patients included 259 (59.6%) male patients and 175 female patients. The mean age was 67.6-year-old, and the mean APACHE II score was 13.8. The SEPSIS cohort had a higher SOFA score and increased use of organ support treatment. The AI algorithm was developed with a shuffle method using 80% of the instances for training and 20% for testing. The established AI algorithm achieved the following: accuracy = 82% ± 1%; sensitivity = 65% ± 5%; specificity = 88% ± 2%; precision = 67% ± 3%; and F1 = 0.66 ± 0.02. The area under the receiver operating characteristic curve (AUROC) was approximately 0.89. The SOFA score was used on the same 1588 instances for sepsis diagnosis, and the result was inferior to our AI algorithm (AUROC = 0.596). CONCLUSION: Using real-time data, collected by EMR, from the ICU daily practice, our AI algorithm established with pre-selected features and XGBoost can provide a timely diagnosis of sepsis with an accuracy greater than 80%. AI algorithm also outperforms the SOFA score in sepsis diagnosis and exhibits practicality as clinicians can deploy appropriate treatment earlier. The early and precise response of this AI algorithm will result in cost reduction, outcome improvement, and benefit for healthcare systems, medical staff, and patients as well.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ijmedinf.2020.104176

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 170

Metadata

Authors
Yuan, K.-C., Tsai, L.-W., Lee, K.-H., Cheng, Y.-W., Hsu, S.-C., Lo, Y.-S., & Chen, R.-J.
Venue
International Journal of Medical Informatics
Publisher
Elsevier BV
Published
2020-09
Volume
141
Pages
104176
ISSN
1386-5056 (ISSN-L)
OpenAlex
W3026865292
Cited by
170
References
8
FWCI
11.98
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The development an artificial intelligence algorithm for early sepsis diagnosis in the intensive care unit. https://app.cochat.ai/papers/10.1016/j.ijmedinf.2020.104176
The paper
Yuan, K.-C., Tsai, L.-W., Lee, K.-H., Cheng, Y.-W., Hsu, S.-C., Lo, Y.-S., & Chen, R.-J. (2020). The development an artificial intelligence algorithm for early sepsis diagnosis in the intensive care unit. International Journal of Medical Informatics. https://doi.org/10.1016/j.ijmedinf.2020.104176

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.