Single Particle Analyzer of Mass: A Charge Detection Mass Spectrometer with a Multi-Detector Electrostatic Ion Trap
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
A new charge detection mass spectrometer that combines array detection and electrostatic ion trapping to repeatedly measure the masses of single ions is described. This instrument has four detector tubes inside an electrostatic ion trap with conical electrodes (cone trap) to provide multiple measurements of an ion on each pass through the trap resulting in a signal gain over a conventional trap with a single detection tube. Simulations of a cone trap and a dual ion mirror trap design indicate that more passes through the trap per unit time are possible with the latter. However, the cone trap has the advantages that ions entering up to 2 mm off the central axis of the trap are still trapped, the trapping time is less sensitive to the background pressure, and only a narrow range of energies are trapped so it can be used for energy selection. The capability of this instrument to obtain information about the molecular weight distributions of heterogeneous high molecular weight samples is demonstrated with 8 MDa polyethylene glycol (PEG) and 50 and 100 nm amine modified polystyrene nanoparticle samples. The measured mass distribution of the PEG sample is centered at 8 MDa. The size distribution obtained from mass measurements of the 100 nm nanoparticle sample is similar to the size distribution obtained from transmission electron microscopy (TEM) images, but most of the smaller nanoparticles observed in TEM images of the 50 nm nanoparticles do not reach a sufficiently high charge to trigger the trap on a single pass and be detected by the mass spectrometer. With the maximum trapping time set to 100 ms, the charge uncertainty is as low as ±2 charges and the mass uncertainty is approximately 2% for PEG and polystyrene ions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biodegradable polymers for food packaging: a review
Siracusa, V., Rocculi, P., Romani, S., & Rosa, M. D. (2008) · Trends in Food Science & Technology · doi:10.1016/j.tifs.2008.07.003 · Cited by 2,126 · cited 1×
“Synthetic polymers are used in a wide variety of applications, from simple homopolymers used in common packaging materials and textiles [1,2], to carefully engineered copolymers and nanoparticles designed for electronics [3] and biomedical technologies [4–6].”
BackgroundPlastics derived from biological sources: present and future: a technical and environmental review
Chen, G.-Q., & Patel, M. K. (2012) · Chemical Reviews · doi:10.1021/cr200162d · Cited by 997 · cited 1×
“Synthetic polymers are used in a wide variety of applications, from simple homopolymers used in common packaging materials and textiles [1,2], to carefully engineered copolymers and nanoparticles designed for electronics [3] and biomedical technologies [4–6].”
BackgroundAdvanced drug delivery devices via self-assembly of amphiphilic block copolymers
Rösler, A., Vandermeulen, G. W. M., & Klok, H.-A. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.09.026 · Cited by 688
High-sensitivity Orbitrap mass analysis of intact macromolecular assemblies
Rose, R. J., Damoc, E., Denisov, E., Makarov, A., & Heck, A. J. R. (2012) · Nature Methods · doi:10.1038/nmeth.2208 · Cited by 392
Dynamics of ions of intact proteins in the Orbitrap mass analyzer
Makarov, A., & Denisov, E. (2009) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2009.03.024 · Cited by 194 · cited 2×
“Single highly charged ions have also been measured with Fourier transform ion cyclotron resonance (FT-ICR) [27–31] and Orbitrap [32,33] instruments.”
MethodResolving Adeno-Associated Viral Particle Diversity With Charge Detection Mass Spectrometry
Pierson, E. E., Keifer, D. Z., Asokan, A., & Jarrold, M. F. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b00883 · Cited by 152
Cited by
Harper, C. C., Elliott, A. G., Oltrogge, L. M., Savage, D. F., & Williams, E. R. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b01669 · Cited by 84
Self-citationZhu, D., Brookes, D. H., Busia, A., Carneiro, A., Fannjiang, C., Popova, G., Shin, D., Donohue, K. C., Lin, L. F., Miller, Z. M., et al. (2024) · Science Advances · doi:10.1126/sciadv.adj3786 · Cited by 63
Self-citation
Metadata
- Authors
- Elliott, A. G., Merenbloom, S. I., Chakrabarty, S., & Williams, E. R.
- Venue
- International Journal of Mass Spectrometry
- Publisher
- Elsevier BV
- Published
- 2017-03
- Volume
- 414
- Pages
- 45-55
- ISSN
- 1387-3806 (ISSN-L)
- OpenAlex
- W2572112922
- Cited by
- 68
- References
- 6
- FWCI
- 2.05
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Single Particle Analyzer of Mass: A Charge Detection Mass Spectrometer with a Multi-Detector Electrostatic Ion Trap. https://app.cochat.ai/papers/10.1016/j.ijms.2017.01.007
- The paper
- Elliott, A. G., Merenbloom, S. I., Chakrabarty, S., & Williams, E. R. (2017). Single Particle Analyzer of Mass: A Charge Detection Mass Spectrometer with a Multi-Detector Electrostatic Ion Trap. International Journal of Mass Spectrometry. https://doi.org/10.1016/j.ijms.2017.01.007
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.