Failed tracheal intubation during obstetric general anaesthesia: a literature review

Open access
Kinsella, S.M., Winton, A.L., Mushambi, M.C., Ramaswamy, K., Swales, H., Quinn, A.C., Popat, M.·2015·International Journal of Obstetric Anesthesia

Abstract

We reviewed the literature on obstetric failed tracheal intubation from 1970 onwards. The incidence remained unchanged over the period at 2.6 (95% CI 2.0 to 3.2) per 1000 anaesthetics (1 in 390) for obstetric general anaesthesia and 2.3 (95% CI 1.7 to 2.9) per 1000 general anaesthetics (1 in 443) for caesarean section. Maternal mortality from failed intubation was 2.3 (95% CI 0.3 to 8.2) per 100000 general anaesthetics for caesarean section (one death per 90 failed intubations). Maternal deaths occurred from aspiration or hypoxaemia secondary to airway obstruction or oesophageal intubation. There were 3.4 (95% CI 0.7 to 9.9) front-of-neck airway access procedures (surgical airway) per 100000 general anaesthetics for caesarean section (one procedure per 60 failed intubations), usually carried out as a late rescue attempt with poor maternal outcomes. Before the late 1990s, most cases were awakened after failed intubation; since the late 1990s, general anaesthesia has been continued in the majority of cases. When general anaesthesia was continued, a laryngeal mask was usually used but with a trend towards use of a second-generation supraglottic airway device. A prospective study of obstetric general anaesthesia found that transient maternal hypoxaemia occurred in over two-thirds of cases of failed intubation, usually without sequelae. Pulmonary aspiration occurred in 8% but the rate of maternal intensive care unit admission after failed intubation was the same as that after uneventful general anaesthesia. Poor neonatal outcomes were often associated with preoperative fetal compromise, although failed intubation and lowest maternal oxygen saturation were independent predictors of neonatal intensive care unit admission.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ijoa.2015.06.008

Cites

45 of 45 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 45 references

Cited by

See all 333

Metadata

Authors
Kinsella, S. M., Winton, A. L., Mushambi, M. C., Ramaswamy, K., Swales, H., Quinn, A. C., & Popat, M.
Venue
International Journal of Obstetric Anesthesia
Publisher
Elsevier BV
Published
2015-11
Volume
24
Issue
4
Pages
356-374
ISSN
0959-289X (ISSN-L)
OpenAlex
W2098369443
Cited by
333
References
45
FWCI
48.64
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Failed tracheal intubation during obstetric general anaesthesia: a literature review. https://app.cochat.ai/papers/10.1016/j.ijoa.2015.06.008
The paper
Kinsella, S. M., Winton, A. L., Mushambi, M. C., Ramaswamy, K., Swales, H., Quinn, A. C., & Popat, M. (2015). Failed tracheal intubation during obstetric general anaesthesia: a literature review. International Journal of Obstetric Anesthesia. https://doi.org/10.1016/j.ijoa.2015.06.008

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.