A novel USP apparatus 4 based release testing method for dispersed systems
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bhardwaj, U., Sura, R., Papadimitrakopoulos, F., & Burgess, D. J. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100103 · Cited by 99 · cited 2×
“Dexamethasone analysis Dexamethasone was analyzed using an HPLC method as described previously (Bhardwaj et al., 2007).”
MethodSelf-citation
Cited by
Alshawwa, S. Z., Kassem, A. A., Farid, R. M., Mostafa, S. K., & Labib, G. S. (2022) · Pharmaceutics · doi:10.3390/pharmaceutics14040883 · Cited by 531
Analytical characterization of liposomes and other lipid nanoparticles for drug delivery
Fan, Y., Marioli, M., & Zhang, K. (2021) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2020.113642 · Cited by 395
A Review of In Vitro Drug Release Test Methods for Nano-Sized Dosage Forms
D’Souza, S. (2014) · Advances in Pharmaceutics · doi:10.1155/2014/304757 · Cited by 262
“An alternate dialysis-CFmethod utilized a dialysis adaptor inside the CF set-up (Figure 7) [29].”
BackgroundMethodNanocarriers for intravenous injection—The long hard road to the market
Wacker, M. (2013) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2013.08.079 · Cited by 170
“Burgess and co-workers developed and patented a dialysis adapter for USP apparatus 4 (Bhardwaj and Burgess, 2010) which is commercially available.810 The unfavorable hydrodynamic situation inside the dialysis bag is one of the most important drawbacks of this method.”
BackgroundMethodDrug releasing nanoplatforms activated by alternating magnetic fields
Mertz, D., Sandre, O., & Bégin-Colin, S. (2017) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/j.bbagen.2017.02.025 · Cited by 119
“This system was adapted to monitor drug release from nanocarriers by incorporation of a 2 mL volume dialysis bag in the loop and validation on liposomal formulation of dexamethasone.[181] Instead of taking aliquots at discrete times, it would be very benefic for data interpretation and modelling of AMF-induced drug re…”
MethodGupta, V., & Trivedi, P. (2018) · Lipid Nanocarriers for Drug Targeting · doi:10.1016/b978-0-12-813687-4.00015-3 · Cited by 96
de Andrade, D. F., Zuglianello, C., Pohlmann, A. R., Guterres, S. S., & Beck, R. C. R. (2015) · AAPS PharmSciTech · doi:10.1208/s12249-015-0330-0 · Cited by 43
Metadata
- Authors
- Bhardwaj, U., & Burgess, D. J.
- Venue
- International Journal of Pharmaceutics
- Publisher
- Elsevier BV
- Published
- 2010-03
- Volume
- 388
- Issue
- 1-2
- Pages
- 287-294
- ISSN
- 0378-5173 (ISSN-L)
- OpenAlex
- W2062342181
- Cited by
- 160
- References
- 1
- FWCI
- 5.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.