The DOI matches its Crossref record; 37 of the 39 references it cites were found in a registry or an index.
Sterilization of implantable polymer-based medical devices: A review
Abstract
This review article is focused on the sterilization techniques used for polymer-based implantable medical devices as well as the regulatory aspects governing sterile medical devices. Polymeric materials are increasingly used in implantable devices due to their biodegradable and biocompatible nature. Patients and medical staff often prefer long-term implantable devices and these can be achieved using high molecular weight polymers. Sterilization of polymer-based implantable devices is critical. Since all implantable devices must be sterile, the effect of the sterilization method on the different device components (such as, the polymer, the drug, the electronics, etc.) has to be considered. A comprehensive summary of the established sterilization methods is provided along with the possible effects on polymers. In addition, novel sterilization methods are also discussed.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The selection of the sterilization method reflects material choice of the implants with polymers; e.g. gamma irradiation is fast and efficient, but can degrade polymers through 'cross-linking, chain scission or a combination of both' (Tipnis and Burgess 2018).”
From Peripheral nerve bionic interface: a review of electrodes (2019) · cites this paper as Tipnis and Burgess 2018
In the citing paper
“These implantable electrodes, carry the highest risk when compared with other medical technologies, are class III devices and therefore have stringent approval process including a premarket approval to weigh the health benefits against the risk (Tipnis and Burgess 2018).”
From Peripheral nerve bionic interface: a review of electrodes (2019) · cites this paper as Tipnis and Burgess 2018
In the citing paper
“These implantable electrodes, carry the highest risk when compared with other medical technologies, are class III devices and therefore have stringent approval process including a premarket approval to weigh the health benefits against the risk (Tipnis and Burgess 2018).”
From Peripheral nerve bionic interface: a review of electrodes (2019) · cites this paper as Tipnis and Burgess 2018
In the citing paper
“These implantable electrodes, carry the highest risk when compared with other medical technologies, are class III devices and therefore have stringent approval process including a premarket approval to weigh the health benefits against the risk (Tipnis and Burgess 2018).”
From Peripheral nerve bionic interface: a review of electrodes (2019) · cites this paper as Tipnis and Burgess 2018
Citations
Cites
Guideline for disinfection and sterilization in healthcare facilities, 2008
Rutala, W. A., & Weber, D. J. (2008) · Infection Control and Hospital Epidemiology · Cited by 1,402
Why Are Total Knee Arthroplasties Failing Today?
Sharkey, P. F., Hozack, W. J., Rothman, R. H., Shastri, S., & Jacoby, S. M. (2002) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-200211000-00003 · Cited by 1,355
Polymeric Biomaterials for Medical Implants and Devices
Teo, A. J. T., Mishra, A., Park, I., Kim, Y.-J., Park, W.-T., & Yoon, Y.-J. (2016) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.5b00429 · Cited by 778
Device‐Associated Infections: A Macroproblem that Starts with Microadherence
Darouiche, R. O. (2001) · Clinical Infectious Diseases · doi:10.1086/323130 · Cited by 767
Applications of synthetic polymers in clinical medicine
Maitz, M. F. (2015) · Biosurface and Biotribology · doi:10.1016/j.bsbt.2015.08.002 · Cited by 726
Degradability of Polymers for Implantable Biomedical Devices
Lyu, S., & Untereker, D. F. (2009) · International Journal of Molecular Sciences · doi:10.3390/ijms10094033 · Cited by 565
Current trends in dental implants
Gaviria, L., Salcido, J., Guda, T., & Ong, J. L. (2014) · 대한구강악안면외과학회지 · doi:10.5125/jkaoms.2014.40.2.50 · Cited by 408
Ethylene oxide sterilization of medical devices: A review
Mendes, G. C., Brandão, T. R. S., & Silva, C. L. M. (2007) · American Journal of Infection Control · doi:10.1016/j.ajic.2006.10.014 · Cited by 398
Sterilization techniques for biodegradable scaffolds in tissue engineering applications
Dai, Z., Ronholm, J., Tian, Y., Sethi, B., & Cao, X. (2016) · Journal of Tissue Engineering · doi:10.1177/2041731416648810 · Cited by 362
Ormiston, J. A., & Serruys, P. W. J. C. (2009) · Circulation Cardiovascular Interventions · doi:10.1161/circinterventions.109.859173 · Cited by 305
Research works printed but not linked: 2
- FDA, 2016, 510, 11
- Oshiro, 2012, Hydrogen peroxide sterilization or hydrogen peroxide plasma sterilization detection indicator, PCT Int. Appl.
Cited by
Sorted by citations
Items 201–233 of 233
SOLUÇÕES PARA MELHORAR A QUALIDADE DE ENERGIA DE SISTEMAS HÍBRIDOS FOTOVOLTAICO-DIESEL
Ferreira, F. S., Marchesan, G., & de Morais, A. P. (2023) · Editora Reflexão Acadêmica eBooks · doi:10.51497/reflex.0000581
FILMES DE POLIURETANO COM ELEVADAS CARACTERÍSTICAS DE IMPERMEABILIDADE
de Oliveira, R., & Molina, E. F. (2023) · Editora Reflexão Acadêmica eBooks · doi:10.51497/reflex.0000583
RESILIÊNCIA DA CADEIA DE SUPRIMENTOS DO HIDROGÊNIO VERDE
Donato, V., Vieira, C. S., Andrade, M. S., Albuquerque, R. V., & Santos, C. C. (2023) · Editora Reflexão Acadêmica eBooks · doi:10.51497/reflex.0000580
Tang, C., Lu, T., Shi, H., & Ye, J. (2023) · Journal of Biomaterials Science Polymer Edition · doi:10.1080/09205063.2023.2230844
Magnetic materials-based medical devices for diagnosis, surgery, and therapy
Bălan, V., & Vereștiuc, L. (2023) · Elsevier eBooks · doi:10.1016/b978-0-12-823294-1.00010-5
Multiscale characterization of additively manufactured PMMA: the influence of sterilization
Rufo‐Martín, C., Mantecón, R., Youssef, G., Miguélez, H., & Díaz‐Álvarez, J. (2024) · Rapid Prototyping Journal · doi:10.1108/rpj-10-2023-0364
Namsaraeva, O., Selvaduray, G. S., Schneider, Y., Holder, Z., Wagner, D., Barker, M., Nichols, L., Bridgford, K., Macdonald, J., Erogbogbo, F., et al. (2024) · Research Square · doi:10.21203/rs.3.rs-4224683/v1
Smith, J. A. M., Petersmann, S., Dominkovic, D., Ali, K. M., Schäfer, U., & Arbeiter, F. J. (2024) · SSRN Electronic Journal · doi:10.2139/ssrn.4798418
Trang, K., Herrera, A. D. P., & Ferrall‐Fairbanks, M. C. (2024) · GEN Biotechnology · doi:10.1089/genbio.2024.0019
New chamber stapes prosthesis: Effect of ionizing radiation on material and functional properties
Kwacz, M., Sadło, J., & Walo, M. (2024) · Nukleonika · doi:10.2478/nuka-2024-0028
Tissue-on-chip, organ-on-chip, and organism-on-chip
Filiz, Y., & Yeşil-Çeliktaş, Ö. (2024) · Elsevier eBooks · doi:10.1016/b978-0-323-95533-1.00004-7
Portable Decontamination System based on Cold Atmospheric Plasma and UV-C Light
Portugal, S., Cárdenas, D., & Capitan‐Barrios, Z. (2024) · International Engineering, Sciences and Technology Conference (IESTEC) · doi:10.1109/iestec62784.2024.10820303
Hapsari, W., Sajidan, Suranto, S., & Hikmayani, N. H. (2025) · BIO Web of Conferences · doi:10.1051/bioconf/202515201029
Toxicology Assessment of Polymeric Material for Implants
Paul, A. K., Chakraborty, G., & Prasad, A. (2025) · Materials horizons · doi:10.1007/978-981-96-9306-1_14
Biomedical Applications of Polymers
Kishida, A. (2025) · Springer handbooks · doi:10.1007/978-981-96-2498-0_4
Taşdelen, B., & Güder, Ö. F. (2025) · European Journal of Engineering and Applied Sciences · doi:10.55581/ejeas.1818279
AlAlaween, W. H., AlAlawin, A. H., Alwaheba, A., & Etoom, M. (2025) · International Conference on Intelligent Informatics and Biomedical Sciences (ICIIBMS) · doi:10.1109/iciibms66230.2025.11316739
Development of electrostrictive P(VDF-TrFE-CTFE) terpolymer for medical applications
Schiava, N. D. (2020) · theses.fr (ABES) · doi:10.70675/fefbdd35z7a4fz42a0z9622z0eef6e1e8720
Biopolymer-based hydrogel electrostatic reinforcement for bone regeneration
Khan, A., Walid, B. M., Chowdhury, M. L., Haque, M. A., Chowdhury, M. I. S., & Hoque, M. E. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-33391-0.00019-4
Microjoining for biomedical device fabrication: a perspective
Zhang, K., Zhou, Y., & Peng, P. (2026) · Advanced Materials Joining · doi:10.1007/s44500-026-00006-z
Mohammadi, S., Bomfim, L., & Unger, W. W. J. (2026) · Biomaterials Advances · doi:10.1016/j.bioadv.2026.214988 · Cited by 1
AlAlaween, W. H., AlAlawin, A. H., Abdallat, M., Etoom, M., Alwaheba, A., Al-Abbadi, M. A., Hajeer, M., Aloweidi, A. S., & Al-Zain, Y. (2026) · Biomedical Materials · doi:10.1088/1748-605x/ae76a4
Elkhashab, M., Sartawi, Z., Lynch, D., Vučen, S. R., & Crean, A. M. (2026) · European Journal of Pharmaceutical Sciences · doi:10.1016/j.ejps.2026.107572
Yang, M. S., & Xian, C. (2026) · Journal of Experimental and Theoretical Analyses · doi:10.3390/jeta4020021
3D printing in ophthalmology: From basic research to clinical transformation
Wu, Z., Ma, Y., Wang, L., Gu, Y., Tang, M., Cui, W., Zhou, X., & Zhao, J. (2026) · Acta Biomaterialia · doi:10.1016/j.actbio.2026.07.038
Zhang, R., Zhou, S., Wang, Y., & Ran, F. (2026) · Chemistry - A European Journal · doi:10.1002/chem.202600021
Introduction to Resorbable Composites for Implants and Fixation Devices
Paul, A. K., Chakraborty, G., Prasad, A., & Mahto, B. (2026) · Wiley eBooks · doi:10.1002/9781394355396.ch1
Casares-López, J. M., Hierro‐Oliva, M., Luque-Agudo, V., González-Martín, M. L., Pacha‐Olivenza, M. A., Gallardo-Moreno, A. M., & Tamurejo-Alonso, P. (2026) · Surfaces and Interfaces · doi:10.1016/j.surfin.2026.110839
Adeyemi, F. O., Ajanaku, O., Ilori, A. O., Okungbowa, E. G., & Ediagbonya, T. F. (2026) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2026.114549
Aladağ, M., Łojkowski, M., Zgłobicka, I. B., Keil, C., Sterzenbach, T., Lauer, G., Burlein, S., & Kurzydłowski, K. J. (2026) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2026.107676
Kaul, S., Gupta, C., Abitha, R., Jain, N., & Nagaich, U. (2026) · Biomedical Materials & Devices · doi:10.1007/s44174-026-00784-0
Yin, H., Wang, T., Wu, F., Zhang, Y., Li, C., Chen, G., & Wang, Q. (2026) · ACS Nano · doi:10.1021/acsnano.6c14220
Metadata
- Authors
- Tipnis, N. P., & Burgess, D. J.
- Affiliations
- University of Connecticut (US)
- Corresponding author
- Burgess, Diane J.
- Venue
- International Journal of Pharmaceutics
- Publisher
- Elsevier BV
- Published
- 2018-06
- Volume
- 544
- Issue
- 2
- Pages
- 455-460
- ISSN
- 0378-5173 (ISSN-L)
- OpenAlex
- W2780274668
- Cited by
- 233
- References
- 39
- Citations by year
- 2026: 19 · 2025: 32 · 2024: 32 · 2023: 36 · 2022: 28 · 2021: 28 · 2020: 26 · 2019: 19 · 2018: 13
- FWCI
- 12.82
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- International Journal of Pharmaceutics (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Immunology and Microbiology › Microbiology › Medical Device Sterilization and Disinfection
- Life Sciences › Immunology and Microbiology › Applied Microbiology and Biotechnology › Antimicrobial agents and applications
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Healthcare Regulation
- Keywords
- sterilization, biomedical implants, sterilization methods, biodegradable polymers, biocompatibility, drug-loaded implants
- MeSH terms
- Biocompatible Materials, Equipment Contamination, Polymers, Sterilization, United States, United States Food and Drug Administration, Guidelines as Topic, Prostheses and Implants
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review