The DOI matches its Crossref record; 37 of the 39 references it cites were found in a registry or an index.
Sterilization of implantable polymer-based medical devices: A review
Abstract
This review article is focused on the sterilization techniques used for polymer-based implantable medical devices as well as the regulatory aspects governing sterile medical devices. Polymeric materials are increasingly used in implantable devices due to their biodegradable and biocompatible nature. Patients and medical staff often prefer long-term implantable devices and these can be achieved using high molecular weight polymers. Sterilization of polymer-based implantable devices is critical. Since all implantable devices must be sterile, the effect of the sterilization method on the different device components (such as, the polymer, the drug, the electronics, etc.) has to be considered. A comprehensive summary of the established sterilization methods is provided along with the possible effects on polymers. In addition, novel sterilization methods are also discussed.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The selection of the sterilization method reflects material choice of the implants with polymers; e.g. gamma irradiation is fast and efficient, but can degrade polymers through 'cross-linking, chain scission or a combination of both' (Tipnis and Burgess 2018).”
From Peripheral nerve bionic interface: a review of electrodes (2019) · cites this paper as Tipnis and Burgess 2018
In the citing paper
“These implantable electrodes, carry the highest risk when compared with other medical technologies, are class III devices and therefore have stringent approval process including a premarket approval to weigh the health benefits against the risk (Tipnis and Burgess 2018).”
From Peripheral nerve bionic interface: a review of electrodes (2019) · cites this paper as Tipnis and Burgess 2018
In the citing paper
“These implantable electrodes, carry the highest risk when compared with other medical technologies, are class III devices and therefore have stringent approval process including a premarket approval to weigh the health benefits against the risk (Tipnis and Burgess 2018).”
From Peripheral nerve bionic interface: a review of electrodes (2019) · cites this paper as Tipnis and Burgess 2018
In the citing paper
“These implantable electrodes, carry the highest risk when compared with other medical technologies, are class III devices and therefore have stringent approval process including a premarket approval to weigh the health benefits against the risk (Tipnis and Burgess 2018).”
From Peripheral nerve bionic interface: a review of electrodes (2019) · cites this paper as Tipnis and Burgess 2018
Citations
Cites
Guideline for disinfection and sterilization in healthcare facilities, 2008
Rutala, W. A., & Weber, D. J. (2008) · Infection Control and Hospital Epidemiology · Cited by 1,402
Why Are Total Knee Arthroplasties Failing Today?
Sharkey, P. F., Hozack, W. J., Rothman, R. H., Shastri, S., & Jacoby, S. M. (2002) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-200211000-00003 · Cited by 1,355
Polymeric Biomaterials for Medical Implants and Devices
Teo, A. J. T., Mishra, A., Park, I., Kim, Y.-J., Park, W.-T., & Yoon, Y.-J. (2016) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.5b00429 · Cited by 778
Device‐Associated Infections: A Macroproblem that Starts with Microadherence
Darouiche, R. O. (2001) · Clinical Infectious Diseases · doi:10.1086/323130 · Cited by 767
Applications of synthetic polymers in clinical medicine
Maitz, M. F. (2015) · Biosurface and Biotribology · doi:10.1016/j.bsbt.2015.08.002 · Cited by 726
Degradability of Polymers for Implantable Biomedical Devices
Lyu, S., & Untereker, D. F. (2009) · International Journal of Molecular Sciences · doi:10.3390/ijms10094033 · Cited by 565
Current trends in dental implants
Gaviria, L., Salcido, J., Guda, T., & Ong, J. L. (2014) · 대한구강악안면외과학회지 · doi:10.5125/jkaoms.2014.40.2.50 · Cited by 408
Ethylene oxide sterilization of medical devices: A review
Mendes, G. C., Brandão, T. R. S., & Silva, C. L. M. (2007) · American Journal of Infection Control · doi:10.1016/j.ajic.2006.10.014 · Cited by 398
Sterilization techniques for biodegradable scaffolds in tissue engineering applications
Dai, Z., Ronholm, J., Tian, Y., Sethi, B., & Cao, X. (2016) · Journal of Tissue Engineering · doi:10.1177/2041731416648810 · Cited by 362
Ormiston, J. A., & Serruys, P. W. J. C. (2009) · Circulation Cardiovascular Interventions · doi:10.1161/circinterventions.109.859173 · Cited by 305
Research works printed but not linked: 2
- FDA, 2016, 510, 11
- Oshiro, 2012, Hydrogen peroxide sterilization or hydrogen peroxide plasma sterilization detection indicator, PCT Int. Appl.
Cited by
Sorted by citations
Properties and Applications of PDMS for Biomedical Engineering: A Review
Miranda, I., Souza, A., Sousa, P. J., Ribeiro, J., Castanheira, E. M. S., Lima, R. A., & Minas, G. M. H. (2021) · Journal of Functional Biomaterials · doi:10.3390/jfb13010002 · Cited by 852
Degradation and stabilization of polyurethane elastomers
Xie, F., Zhang, T., Bryant, P., Kurusingal, V., Colwell, J. M., & Laycock, B. G. (2019) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2018.12.003 · Cited by 740
Fabrication of Biomedical Scaffolds Using Biodegradable Polymers.
Kirillova, A., Yeazel, T. R., Asheghali, D., Petersen, S. R., Dort, S., Gall, K., & Becker, M. L. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01200 · Cited by 368
Ghosal, K., Agatemor, C., Špitálsky, Z., Thomas, S., & Kny, E. (2019) · Chemical Engineering Journal · doi:10.1016/j.cej.2018.10.117 · Cited by 278
Piezoelectric energy harvesting systems for biomedical applications
Panda, S., Hajra, S., Mistewicz, K., In-na, P., Sahu, M., Rajaitha, P. M., & Kim, H. J. (2022) · Nano Energy · doi:10.1016/j.nanoen.2022.107514 · Cited by 274
Next-generation tissue-engineered heart valves with repair, remodelling and regeneration capacity
Fioretta, E. S., Motta, S. E., Lintas, V., Loerakker, S., Parker, K. K., Baaijens, F. P. T., Falk, V., Hoerstrup, S. P., & Emmert, M. Y. (2021) · Nature Reviews Cardiology · doi:10.1038/s41569-020-0422-8 · Cited by 262
Garot, C., Bettega, G., & Picart, C. (2020) · Advanced Functional Materials · doi:10.1002/adfm.202006967 · Cited by 215
Recent advances in sterilization and disinfection technology: A review
Bharti, B., Li, H., Ren, Z., Zhu, R., & Zhu, Z. (2022) · Chemosphere · doi:10.1016/j.chemosphere.2022.136404 · Cited by 188
Wu, B., Li, Y., Su, K., Tan, L., Liu, X., Cui, Z., Yang, X., Liang, Y., Li, Z., Zhu, S., et al. (2019) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2019.05.074 · Cited by 172
Solid implantable devices for sustained drug delivery
Magill, E., Demartis, S., Gavini, E., Permana, A. D., Thakur, R. R. S., Adrianto, M. F., Waite, D. T., Glover, K., Picco, C. J., Korelidou, A., et al. (2023) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2023.114950 · Cited by 152
Yogev, D., Goldberg, T., Arami, A., Tejman‐Yarden, S., Winkler, T. E., & Maoz, B. M. (2023) · APL Bioengineering · doi:10.1063/5.0152290 · Cited by 147
Medical microrobots in reproductive medicine from the bench to the clinic
Nauber, R., Goudu, S. R., Goeckenjan, M., Bornhäuser, M., Ribeiro, C., & Medina‐Sánchez, M. (2023) · Nature Communications · doi:10.1038/s41467-023-36215-7 · Cited by 127
Hawthorne, D., Pannala, A. S., Sandeman, S. R., & Lloyd, A. W. (2022) · Journal of Drug Delivery Science and Technology · doi:10.1016/j.jddst.2022.103936 · Cited by 127
Interfaces with the peripheral nervous system for the control of a neuroprosthetic limb: a review
Yildiz, K. A., Shin, A. Y., & Kaufman, K. R. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00667-5 · Cited by 113
Ni, Y., Wang, R., Zhang, W., Shi, S., Zhu, W., Liu, M., Yang, C., Xie, X., & Wang, J. (2020) · Chemical Engineering Journal · doi:10.1016/j.cej.2020.126528 · Cited by 111
Fernández, I. A., Haugen, H. J., López‐Peña, M., González‐Cantalapiedra, A., & Muñoz, F. M. G. (2023) · Acta Biomaterialia · doi:10.1016/j.actbio.2023.07.013 · Cited by 108
How to Sterilize Polylactic Acid Based Medical Devices?
Pérez-Davila, S., González-Rodríguez, L., Chiussi, S., Serra, J., & González, P. (2021) · Polymers · doi:10.3390/polym13132115 · Cited by 103
Silk-Based Composite Scaffolds for Tissue Engineering Applications
Tandon, S., Kandasubramanian, B., & Ibrahim, S. M. (2020) · Industrial & Engineering Chemistry Research · doi:10.1021/acs.iecr.0c02195 · Cited by 93
In Vitro Thrombogenicity Testing of Biomaterials
Braune, S., Latour, R. A., Reinthaler, M., Landmesser, U., Lendlein, A., & Jung, F. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201900527 · Cited by 87
Clinical translation of wireless soft robotic medical devices
Wang, T., Wu, Y., Yıldız, E., Kanyas, S., & Sitti, M. (2024) · Nature Reviews Bioengineering · doi:10.1038/s44222-024-00156-7 · Cited by 96
Smart closed-loop drug delivery systems
Paci, M. M., Saha, T., Djassemi, O., Wu, S. T., Chua, C. Y. X., Wang, J., & Grattoni, A. (2025) · Nature Reviews Bioengineering · doi:10.1038/s44222-025-00328-z · Cited by 96
Roadmap for Clinical Translation of Mobile Microrobotics
Bozuyuk, U., Wrede, P., Yıldız, E., & Sitti, M. (2024) · Advanced Materials · doi:10.1002/adma.202311462 · Cited by 81
de Lima, G. G., de Lima, D. W. F., de Oliveira, M. J. A., Lugão, A. B., Alcantara, M. T. S., Devine, D. M., & de Sá, M. J. C. (2018) · ACS Applied Bio Materials · doi:10.1021/acsabm.8b00369 · Cited by 73
Sterilization of Polymeric Implants: Challenges and Opportunities
Herczeg, C. K., & Song, J. (2022) · ACS Applied Bio Materials · doi:10.1021/acsabm.2c00793 · Cited by 84
Peripheral nerve bionic interface: a review of electrodes
Russell, C., Roche, A. D., & Chakrabarty, S. (2019) · International Journal of Intelligent Robotics and Applications · doi:10.1007/s41315-019-00086-3 · Cited by 67
Wang, L., Guo, X., Chen, J., Zhen, Z., Cao, B., Wan, W., Dou, Y., Pan, H., Xu, F., Zhang, Z., et al. (2021) · Bioactive Materials · doi:10.1016/j.bioactmat.2021.07.031 · Cited by 69
Hybrid Nanogels: Stealth and Biocompatible Structures for Drug Delivery Applications
Eslami, P., Rossi, F., & Fedeli, S. (2019) · Pharmaceutics · doi:10.3390/pharmaceutics11020071 · Cited by 64
Clinical translation of personalized bioengineered implant scaffolds
Xu, C., & Ivanovski, S. (2025) · Nature Reviews Bioengineering · doi:10.1038/s44222-024-00269-z · Cited by 62
Parın, F. N., Aydemir, Ç. İ., Taner, G., & Yıldırım, K. (2021) · Journal of Industrial Textiles · doi:10.1177/1528083721997185 · Cited by 61
Neguț, I., Albu, C., & Bita, B. I. (2024) · Coatings · doi:10.3390/coatings14030256 · Cited by 57
Aging of 3D Printed Polymers under Sterilizing UV-C Radiation
Amza, C. G., Zapciu, A., Baciu, F., Vasile, M. I., & Popescu, D. (2021) · Polymers · doi:10.3390/polym13244467 · Cited by 59
Polymers for implantable devices
Ershad‐Langroudi, A., Babazadeh, N., Alizadegan, F., Mousaei, S. M., & Moradi, G. (2024) · Journal of Industrial and Engineering Chemistry · doi:10.1016/j.jiec.2024.03.030 · Cited by 51
Salwa, Chevala, N. T., Jitta, S. R., Marques, S. M., Vaz, V. M., & Kumar, L. (2021) · Journal of Drug Delivery Science and Technology · doi:10.1016/j.jddst.2021.102711 · Cited by 50
A tutorial review on bimetallic nanoparticles loaded in smart organic polymer microgels/hydrogels
Arif, M. (2023) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2023.121346 · Cited by 49
Wireless Battery-free and Fully Implantable Organ Interfaces
Bhatia, A., Hanna, J., Stuart, T., Kasper, K. A., Clausen, D. M., & Gutruf, P. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00425 · Cited by 50
Testing drug release from medicated contact lenses: The missing link to predict in vivo performance
Pereira-da-Mota, A. F., Phan, C., Concheiro, Á., Jones, L., & Alvarez‐Lorenzo, C. (2022) · Journal of Controlled Release · doi:10.1016/j.jconrel.2022.02.014 · Cited by 50
Zamani, Y., Mohammadi, J., Amoabediny, G., Visscher, D. O., Helder, M. N., Zandieh‐Doulabi, B., & Klein‐Nulend, J. (2018) · Biomedical Materials · doi:10.1088/1748-605x/aaeb82 · Cited by 45
Effect of gamma sterilization on the properties of microneedle array transdermal patch system
Swathi, H. P., Matadh, A. V., Guin, J. P., Murthy, S. N., Kanni, P., Varshney, L., Suresh, S., & Shivakumar, H. N. (2020) · Drug Development and Industrial Pharmacy · doi:10.1080/03639045.2020.1742144 · Cited by 45
Arenobufagin-loaded PEG-PLA nanoparticles for reducing toxicity and enhancing cancer therapy
Jiaying, Y., Sun, B., Xiaolu, W., Yanyan, Z., Hong-jie, W., Si, N., Gao, B., Linna, W., Zhang, Y., Gao, W., et al. (2023) · Drug Delivery · doi:10.1080/10717544.2023.2177362 · Cited by 41
Chausse, V., Iglesias, C., Bou-Petit, E., Ginebra, M.-P., & Pegueroles, M. (2023) · Polymer Testing · doi:10.1016/j.polymertesting.2022.107817 · Cited by 39
AI-aided geometric design of anti-infection catheters
Zhou, T., Wan, X., Huang, D. Z., Li, Z., Peng, Z., Anandkumar, A., Brady, J. F., Sternberg, P. W., & Daraio, C. (2024) · Science Advances · doi:10.1126/sciadv.adj1741 · Cited by 40
Umeyor, C. E., Shelke, V., Pol, A., Kolekar, P., Jadhav, S. A., Tiwari, N., Anure, A., Nayak, A., Bairagi, G., Agale, A., et al. (2023) · Future Journal of Pharmaceutical Sciences · doi:10.1186/s43094-023-00553-6 · Cited by 38
Zada, M. H., Kumar, A., Elmalak, O., Mechrez, G., & Domb, A. J. (2019) · ACS Omega · doi:10.1021/acsomega.9b02889 · Cited by 37
Effect of UV-C Radiation on 3D Printed ABS-PC Polymers
Amza, C. G., Zapciu, A., Baciu, F., & Radu, C. (2023) · Polymers · doi:10.3390/polym15081966 · Cited by 37
Robles-Linares, J. A., Figueroa-Cavazos, J. O., Chuck‐Hernández, C., Siller, H. R., Rodriguez, C. A., & Martínez-López, J. I. (2018) · Materials · doi:10.3390/ma11122540 · Cited by 34
Santos-Rosales, V., Magariños, B., Starbird, R., Suárez-González, J., Fariña, J. B., Alvarez-Lorenzo, C., & García-González, C. A. (2021) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2021.120801 · Cited by 32
Gamma sterilization of collagen/hydroxyapatite composites: Validation and radiation effects
Gomes, A. D. S., de Oliveira, A. A. R., Houmard, M., & Nunes, E. H. M. (2021) · Applied Radiation and Isotopes · doi:10.1016/j.apradiso.2021.109758 · Cited by 32
Cingolani, A., Casalini, T., Caimi, S., Klaue, A., Sponchioni, M., Rossi, F., & Perale, G. (2018) · Polymers · doi:10.3390/polym10080851 · Cited by 31
Effect of beta-based sterilization on P(VDF-TrFE-CFE) terpolymer for medical applications
Schiava, N. D., Pedroli, F., Thetpraphi, K., Flocchini, A., Le, M., Lermusiaux, P., Capsal, J., & Cottinet, P. (2020) · Scientific Reports · doi:10.1038/s41598-020-65893-2 · Cited by 31
Chen, J., Ning, E., Wang, Z., Jing, Z., Wei, G., Wang, X., & Ma, P. (2021) · Drug Delivery · doi:10.1080/10717544.2021.1945167 · Cited by 31
Photoresponsive polymeric microneedles: An innovative way to monitor and treat diseases
Singh, P., Youden, B., Carrier, A. J., Oakes, K. D., Servos, M. R., Jiang, R., Lin, S., Nguyen, T. D., & Zhang, X. (2022) · Journal of Controlled Release · doi:10.1016/j.jconrel.2022.12.036 · Cited by 32
Krug, N., Zarges, J., & Heim, H. (2023) · Polymers · doi:10.3390/polym15163461 · Cited by 30
Hydrogels as Scaffolds in Bone‐Related Tissue Engineering and Regeneration
Jurczak, P., & Lach, S. (2023) · Macromolecular Bioscience · doi:10.1002/mabi.202300152 · Cited by 29
Thermoresponsive and Injectable Hydrogel for Tissue Agnostic Regeneration
Calder, D., Fathi, A., Oveissi, F., Maleknia, S. D., Abrams, T., Wang, Y., Maitz, J., Tsai, K. H.-Y., Maitz, P., Chrzanowski, W., et al. (2022) · Advanced Healthcare Materials · doi:10.1002/adhm.202201714 · Cited by 30
Martínez, J. I., Quiles‐Carrillo, L., Boronat, T., Torres‐Giner, S., & Covas, J. A. (2020) · Polymers · doi:10.3390/polym12061389 · Cited by 28
Biodegradable Block Copolymers and Their Applications for Drug Delivery
Soni, V., Pandey, V., Asati, S., Gour, V., & Tekade, R. K. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-817909-3.00011-x · Cited by 27
A bio-inert and thermostable zwitterionic copolymer for the surface modification of PVDF membranes
Tang, S.-H., Venault, A., Hsieh, C., Dizon, G. V., Lo, C., & Chang, Y. (2019) · Journal of Membrane Science · doi:10.1016/j.memsci.2019.117655 · Cited by 27
Gradwohl, M., Chai, F., Payen, J., Guerreschi, P., Marchetti, P., & Blanchemain, N. (2021) · Polymers · doi:10.3390/polym13040572 · Cited by 27
Electrospun Polylactic Acid-Based Fibers Loaded with Multifunctional Antibacterial Biobased Polymers
Chiloeches, A., Cuervo‐Rodríguez, R., Gil-Romero, Y., Fernández‐García, M., Echeverría, C., & Muñoz‐Bonilla, A. (2022) · ACS Applied Polymer Materials · doi:10.1021/acsapm.2c00928 · Cited by 27
Truong, T., Nguyen, T., Huang, X., Ashok, A., Yadav, S., Park, Y., Thai, M. T., Nguyen, N., Fallahi, H., Peng, S., et al. (2023) · Advanced Functional Materials · doi:10.1002/adfm.202211781 · Cited by 26
del‐Mazo‐Barbara, L., Gómez-Cuyàs, J., Orozco, L. I. M., Pérez, O. O. S., Bou‐Petit, E., & Ginebra, M. (2024) · Polymer Testing · doi:10.1016/j.polymertesting.2024.108566 · Cited by 25
Capsule robots for the monitoring, diagnosis, and treatment of intestinal diseases
Wei, X., Xi, P., Chen, M., Wen, Y., Wu, H., Wang, L., Zhu, Y., Ren, Y., & Gu, Z. (2024) · Materials Today Bio · doi:10.1016/j.mtbio.2024.101294 · Cited by 26
From the synthesis of wearable polymer sensors to their potential for reuse and ultimate fate
Ajeev, A., Warfle, T., Maslaczynska-Salome, S., Alipoori, S., Duprey, C., & Wujcik, E. K. (2025) · Chemical Science · doi:10.1039/d5sc01634g · Cited by 25
Powers, J. M., Muñoz, K. D. R., Parkerson, J., Nigro, L. C., & Blanchet, N. P. (2021) · Plastic & Reconstructive Surgery · doi:10.1097/prs.0000000000008519 · Cited by 25
Recent advances in selective laser–material interaction for biomedical device applications
Um, S., Hwang, S., Grigoropoulos, C. P., Jeon, H., & Ko, S. H. (2022) · Applied Physics Reviews · doi:10.1063/5.0101634 · Cited by 26
Kogelheide, F., Voigt, F., Hillebrand, B., Moeller, R., Fuchs, F. M., Gibson, A. R., Awakowicz, P., Stapelmann, K., & Fiebrandt, M. (2020) · Journal of Physics D Applied Physics · doi:10.1088/1361-6463/ab77cc · Cited by 25
Jain, S., Yassin, M. A., Fuoco, T., Mohamed‐Ahmed, S., Vindenes, H. A., Mustafa, K., & Finne‐Wistrand, A. (2021) · Materials Science and Engineering C · doi:10.1016/j.msec.2021.112020 · Cited by 26
Chen, J., Xia, Y., Lan, Q., Hu, M., Xu, Y., Wu, Q., Liu, X., & Liu, Y. (2023) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2023.123473 · Cited by 24
Li, S., Qi, M., Yang, Q., Shi, F., Liu, C., Du, J., Sun, Y. L., Li, C., & Dong, B. (2022) · Journal of Functional Biomaterials · doi:10.3390/jfb13040227 · Cited by 23
Effects of UV Exposure Time on Nanofiber Wound Dressing Properties During Sterilization
Tort, S., Tuğcu-Demiröz, F., Yıldız, S., & Acartürk, F. (2019) · Journal of Pharmaceutical Innovation · doi:10.1007/s12247-019-09383-7 · Cited by 23
Fabrication and Analysis of Polydimethylsiloxane (PDMS) Microchannels for Biomedical Application
Tayyaba, S., Ashraf, M. W., Ahmad, Z., Wang, N., Afzal, M. J., & Afzulpurkar, N. (2020) · Processes · doi:10.3390/pr9010057 · Cited by 23
Krug, N., Zarges, J., & Heim, H. (2024) · Polymer Testing · doi:10.1016/j.polymertesting.2024.108362 · Cited by 22
Domagała, I., Przystupa, К., Firlej, M., Pieniak, D., Gil, L., Borucka, A., Naworol, I., Biedziak, B., & Levkiv, M. (2021) · Materials · doi:10.3390/ma14112925 · Cited by 21
Ghani, S. A. C., Mohamed, S. R., Sha’ban, M., Harun, W. S. W., & Noar, N. A. Z. M. (2020) · Procedia CIRP · doi:10.1016/j.procir.2020.05.122 · Cited by 20
Combined sterilization and fabrication of drug-loaded scaffolds using supercritical CO2 technology
Santos‐Rosales, V., Magariños, B., Alvarez‐Lorenzo, C., & García‐González, C. A. (2021) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2021.121362 · Cited by 19
Effect of Chemical Disinfection on Chitosan Coated PMMA and PETG Surfaces—An In Vitro Study
Walczak, K., Thiele, J., Geisler, D., Boening, K. W., & Wieckiewicz, M. A. (2018) · Polymers · doi:10.3390/polym10050536 · Cited by 19
Interfacial nanoarchitectonics for responsive cellular biosystems
Song, J., Jia, X., & Ariga, K. (2020) · Materials Today Bio · doi:10.1016/j.mtbio.2020.100075 · Cited by 18
Wierzbicki, J., Nowacki, M. S., Chrzanowska, M., Matkowski, R., Ziętek, M., Nowacka, K., Maciejczyk, A., & Pawlak, E. (2020) · Advances in Clinical and Experimental Medicine · doi:10.17219/acem/126296 · Cited by 21
Ramaraju, H., McAtee, A. M., Akman, R. E., Verga, A., Bocks, M. L., & Hollister, S. J. (2022) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.35205 · Cited by 18
Kremser, T., Susoff, M. L., Roth, S., Kaschta, J., & Schubert, D. W. (2019) · Journal of Applied Polymer Science · doi:10.1002/app.48436 · Cited by 17
A Preclinical Animal Model for the Study of Scaffold-Guided Breast Tissue Engineering
Cheng, M., Janzekovic, J., Mohseni, M., Savi, F. M., McGovern, J., Galloway, G. J., Wong, C., Saifzadeh, S., Wagels, M., & Hutmacher, D. W. (2021) · Tissue Engineering Part C Methods · doi:10.1089/ten.tec.2020.0387 · Cited by 17
Küffer, M., Drescher, D., & Becker, K. (2022) · Applied Sciences · doi:10.3390/app12083820 · Cited by 17
Hickok, N. J., Li, B., Oral, E., Zaat, S. A. J., Armbruster, D. A., Atkins, G. J., Chen, A. F., Coraça-Huber, D. C., Dai, T., Greenfield, E. M., et al. (2023) · Journal of Orthopaedic Research® · doi:10.1002/jor.25774 · Cited by 17
Implantable biosensors for musculoskeletal health
Nash, K. E., Ong, K. G., & Guldberg, R. E. (2022) · Connective Tissue Research · doi:10.1080/03008207.2022.2041002 · Cited by 17
Zhan, Y.-L., Wen, K.-C., Li, Z. W., Zang, J., Sun, P., & Li, F. (2024) · Composites Part B Engineering · doi:10.1016/j.compositesb.2024.111554 · Cited by 16
2-Heptylcyclopropane-1-Carboxylic Acid Disperses and Inhibits Bacterial Biofilms
Harrison, Z. L., Awais, R., Harris, M., Raji, B., Hoffman, B. C., Baker, D. L., & Jennings, J. A. (2021) · Frontiers in Microbiology · doi:10.3389/fmicb.2021.645180 · Cited by 16
A non-invasive multipoint product temperature measurement for pharmaceutical lyophilization
Jiang, X., Kazarin, P., Sinanis, M. D., Darwish, A., Raghunathan, N., Alexeenko, A. A., & Peroulis, D. (2022) · Scientific Reports · doi:10.1038/s41598-022-16073-x · Cited by 16
Chen, Y. Y., Neff, M., McEvoy, B., Cao, Z. Q., Pezzoli, R., Murphy, A., Gately, N., Jnr, M. H., Rowan, N. J., & Devine, D. M. (2019) · Polymer · doi:10.1016/j.polymer.2019.121870 · Cited by 16
Rickert, C. A., Bauer, M. G., Hoffmeister, J. C., & Lieleg, O. (2021) · Advanced Materials Interfaces · doi:10.1002/admi.202101716 · Cited by 15
Drzeżdżon, J., Chmurzyński, L., & Jacewicz, D. (2018) · Journal of Chemical Sciences · doi:10.1007/s12039-018-1515-3 · Cited by 15
A fan-shaped plasma reactor for mixing enhancement in a closed chamber
Portugal, S., Choudhury, B., Lilley, A. J., Charters, C., Porrello, C., Lin, J., & Roy, S. (2020) · Journal of Physics D Applied Physics · doi:10.1088/1361-6463/ab7e64 · Cited by 15
Recent Advances in Lignin Modification and Its Application in Wastewater Treatment
Wang, B., Sun, D., Yuan, T., Song, G., & Sun, R. (2021) · ACS symposium series · doi:10.1021/bk-2021-1377.ch007 · Cited by 16
Sapkota, A., Mondal, A., Chug, M. K., & Brisbois, E. J. (2023) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.37560 · Cited by 15
Guadarrama-Escobar, O. R., Valdés-Alvarez, C. A., Constantino-González, K. S., Serrano-Castañeda, P., Peña‐Juárez, M. C., Morales-Florido, M. I., Salgado-Machuca, M., Pérez, B. R., Rodríguez-Cruz, I. M., Estrada, D. V., et al. (2024) · Pharmaceutics · doi:10.3390/pharmaceutics16020294 · Cited by 14
Cao, X., Tian, N., Dong, X., & Cheng, C. (2019) · Coatings · doi:10.3390/coatings9050284 · Cited by 14
Characteristics of key microorganisms and metabolites in irradiated marbled beef
Zhang, J., Zhang, Q., & Li, F. (2023) · Meat Science · doi:10.1016/j.meatsci.2023.109121 · Cited by 13
Robinson, K. J., Voelcker, N. H., & Thissen, H. W. (2024) · Acta Biomaterialia · doi:10.1016/j.actbio.2024.12.037 · Cited by 12
Manchester, R. A., Todorova, T. Z., Werner‐Zwanziger, U., & Boyd, D. (2021) · Journal of Non-Crystalline Solids · doi:10.1016/j.jnoncrysol.2021.120982 · Cited by 12
A comprehensive protocol for PDMS fabrication for use in cell culture
Greaney, A. J., McCarthy, C. M., Vethil, J. P., Abubaker, M., Reardon, E. C., Crowley, F. D., Cunnane, E. M., & Mulvihill, J. J. (2025) · PLoS ONE · doi:10.1371/journal.pone.0323283 · Cited by 14
Dual-Function Biomaterials for Postoperative Osteosarcoma: Tumor Suppression and Bone Regeneration
Dong, H. F., Zhang, Q., Feng, Z.-Y., Huang, K., Nie, R., Li, L., Duan, H., & Xie, H.-Q. (2025) · Research · doi:10.34133/research.0978 · Cited by 12
Metadata
- Authors
- Tipnis, N. P., & Burgess, D. J.
- Affiliations
- University of Connecticut (US)
- Corresponding author
- Burgess, Diane J.
- Venue
- International Journal of Pharmaceutics
- Publisher
- Elsevier BV
- Published
- 2018-06
- Volume
- 544
- Issue
- 2
- Pages
- 455-460
- ISSN
- 0378-5173 (ISSN-L)
- OpenAlex
- W2780274668
- Cited by
- 233
- References
- 39
- Citations by year
- 2026: 19 · 2025: 32 · 2024: 32 · 2023: 36 · 2022: 28 · 2021: 28 · 2020: 26 · 2019: 19 · 2018: 13
- FWCI
- 12.82
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- International Journal of Pharmaceutics (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Immunology and Microbiology › Microbiology › Medical Device Sterilization and Disinfection
- Life Sciences › Immunology and Microbiology › Applied Microbiology and Biotechnology › Antimicrobial agents and applications
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Healthcare Regulation
- Keywords
- sterilization, biomedical implants, sterilization methods, biodegradable polymers, biocompatibility, drug-loaded implants
- MeSH terms
- Biocompatible Materials, Equipment Contamination, Polymers, Sterilization, United States, United States Food and Drug Administration, Guidelines as Topic, Prostheses and Implants
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review