Dynamic behavior of a direct expansion evaporator under frosting condition. Part II. Field investigation on a shipping container
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Tso et al. [52] and Hwang and Cho [18] report model deviations compared to experimental data of less than 6% for the heat transfer rate for fin and tube heat exchangers.
“Tso et al. [52] and Hwang and Cho [18] report model deviations compared to experimental data of less than 6% for the heat transfer rate for fin and tube heat exchangers.”
From Model for cyclic frosting and defrosting of flat tube heat exchangers: Theoretical analysis and experimental validation (2023) · cites this paper as [52]
Tso et al. [52] develop a model for the air-side pressure drop of fin and tube heat exchangers, and report a deviation of less than 20% from experimental data.
“Tso et al. [52] develop a model for the air-side pressure drop of fin and tube heat exchangers, and report a deviation of less than 20% from experimental data.”
From Model for cyclic frosting and defrosting of flat tube heat exchangers: Theoretical analysis and experimental validation (2023) · cites this paper as [52]
Tso et al. [52] report deviations in their model for fin and tube heat exchangers within 26%.
“Tso et al. [52] report deviations in their model for fin and tube heat exchangers within 26%.”
From Model for cyclic frosting and defrosting of flat tube heat exchangers: Theoretical analysis and experimental validation (2023) · cites this paper as [52]
Cites
Performance of finned tube heat exchangers operating under frosting conditions
Yan, W.-M., Li, H.-Y., Wu, Y.-J., Lin, J.-Y., & Chang, W.-R. (2003) · International Journal of Heat and Mass Transfer · doi:10.1016/s0017-9310(02)00346-0 · Cited by 95 · see citing works
Seker, D., Karatas, H., & Egrican, P. D. N. (2004) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2003.12.004 · Cited by 56 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Experimental study on frost growth and dynamic performance of air source heat pump system
Guo, X.-M., Chen, Y.-G., Wang, W.-H., & Chen, C.-Z. (2008) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2008.01.007 · Cited by 173 · see citing works
Patil, M. S., Seo, J.-H., & Lee, M.-Y. (2017) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2016.11.107 · Cited by 86 · see citing works
Westhaeuser, J., Schulze, C., Albrecht, J.-C., Tegethoff, W., Lemke, N., & Koehler, J. (2023) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2023.120140 · Cited by 12 · see citing works
- Authors
- Tso, C. P., Cheng, Y. C., & Lai, A. C. K.
- Affiliations
- Multimedia University (MY)
- Nanyang Technological University (SG)
- ORCID
- Venue
- International Journal of Refrigeration
- Publisher
- Elsevier BV
- Published
- 2006-06
- Volume
- 29
- Issue
- 4
- Pages
- 624-631
- ISSN
- 0140-7007 (ISSN-L)
- OpenAlex
- W2079924475
- Cited by
- 6
- References
- 2
- Citations by year
- 2026: 1 · 2023: 1 · 2016: 1 · 2012: 1
- FWCI
- 0.83
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- International Journal of Refrigeration (publishedVersion)
- Siti Hasmah Digital Library-MMU Institutiona Repository (Multimedia University) (submittedVersion)
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
- Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
- Physical Sciences › Engineering › Mechanical Engineering › Adsorption and Cooling Systems
- Keywords
- frost formation, refrigerated containers, R12 refrigerant, fieldwork, numerical model validation, outlet air temperature, air pressure drop, heat transfer
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review