Cited by 95Heat Transfer and OptimizationRefrigeration and Air Conditioning TechnologiesHeat Transfer Mechanisms

Performance of finned tube heat exchangers operating under frosting conditions

Yan, Wei-Mon, Li, Hung-Yi, Wu, Yeun-Jong, Lin, Jian-Yuan, Chang, Wen-Ruey·2003·International Journal of Heat and Mass Transfer

Integrity signals

Registry

Crossref · 10.1016/s0017-9310(02)00346-0

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Senshu et al. and Yan et al. observed that mean fin temperature increased as air velocity increased, leading to lower frosting rate, and that surface temperature became colder as air velocity decreased, increasing frosting rate.

    “Senshu et al. (1990) explicated that the mean temperature of fin increased as the air velocity increased which leaded to lower frosting rate.Yan et al. (2003) further explained that the surface temperature become colder as the air velocity decreased.Lower temperature tends to increase the frosting rate.”

    From Studies of an air cooler under frost condition (2019) · cites this paper as Yan et al. (2003)

  • The result is agreeable with Gatchilov and Ivanova (1979) and Yan et al. (2003).

    “This is also agreeable with Gatchilov and Ivanova (1979) and Yan et al. (2003).”

    From Studies of an air cooler under frost condition (2019) · cites this paper as Yan et al. (2003)

  • The trend of change in air pressure drop is consistent with results reported by Senshu et al. (1990) and Yan et al. (2003).

    “The trend of change in air pressure drop is consistent with the results reported by other researchers such as Senshu et al. (1990) and Yan et al. (2003).”

    From Studies of an air cooler under frost condition (2019) · cites this paper as Yan et al. (2003)

  • Such trends have been reported by Senshu et al. (1990) and Yan et al. (2003).

    “Such trends have also been reported by Senshu et al. (1990) and Yan et al. (2003).”

    From Studies of an air cooler under frost condition (2019) · cites this paper as Yan et al. (2003)

  • Most heat exchangers used in industrial and domestic refrigerators have been developed experimentally.

    “However, most heat exchangers used in industrial and domestic refrigerators have been developed experimentally [18-20].”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Yan, W.-M., Li, H.-Y., Wu, Y.-J., Lin, J.-Y., & Chang, W.-R.
Affiliations
  • Huafan University (TW)
  • Industrial Technology Research Institute (TW)
Corresponding author
Yan, Wei-Mon
Venue
International Journal of Heat and Mass Transfer
Publisher
Elsevier BV
Published
2003-02
Volume
46
Issue
5
Pages
871-877
ISSN
0017-9310 (ISSN-L)
OpenAlex
W2006413981
Cited by
95
References
5
Citations by year
2026: 5 · 2025: 6 · 2024: 4 · 2023: 4 · 2022: 4 · 2021: 4 · 2020: 1 · 2019: 6 · 2018: 6 · 2017: 8 · 2016: 2 · 2015: 6 · 2014: 5 · 2013: 4 · 2012: 5
FWCI
6.11
Type
journal article
Language
en
Open access
closed
Locations
International Journal of Heat and Mass Transfer (publishedVersion)
Funders
National Science Council
Topics
  • Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
  • Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
  • Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer Mechanisms
Keywords
finned tube heat exchanger, frost formation, fin spacing, relative humidity, air temperature, refrigerant temperature, air flow rate, heat transfer coefficient, pressure drop, heat transfer rate

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review