Modeling and performance analyses of evaporators in frozen-food supermarket display cabinets at low temperatures
The DOI matches its Crossref record; 36 of the 37 references it cites were found in a registry or an index.
Abstract
This paper presents modeling and experimental analyses of evaporators in ‘‘in situ’’ frozen-food display cabinets at low temperatures in the supermarket industry. Extensive experiments were conducted to measure store and display cabinet relative humidities and temperatures, and pressures, temperatures and mass flow rates of the refrigerant. The mathematical model adopts various empirical correlations of heat transfer coefficients and frost properties in a fin-tube heat exchanger in order to investigate the influence of indoor conditions on the performance of the display cabinets. The model is validated with the experimental data of ‘‘in situ’’ cabinets. The model would be a good guide tool to the design engineers to evaluate the performance of supermarket display cabinet heat exchangers under various store conditions.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
New equations for heat and mass transfer in turbulent pipe and channel flow
Gnielinski, V. (1976) · Medical Entomology and Zoology · Cited by 4,037
Kays, W. M., London, A. L., & Eckert, E. R. G. (1960) · Journal of Applied Mechanics · doi:10.1115/1.3644004 · Cited by 2,840
Correlation for Boiling Heat Transfer to Saturated Fluids in Convective Flow
Chen, J. C. (1966) · Industrial & Engineering Chemistry Process Design and Development · doi:10.1021/i260019a023 · Cited by 1,990
Thermal environmental engineering
(1962) · Journal of the Franklin Institute · doi:10.1016/0016-0032(62)90922-5 · Cited by 930
(2017) · Elsevier eBooks · doi:10.1016/c2014-0-03422-3 · Cited by 818
CHAPMAN, A. J. (1960) · Cited by 494
Study of frost properties correlating with frost formation types
Hayashi, Y., Aoki, A., Adachi, S., & Hori, K. (1977) · Journal of Heat Transfer · doi:10.1115/1.3450675 · Cited by 402
Seker, D., Karatas, H., & Egrican, N. (2004) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2003.12.003 · Cited by 147
(1967) · ASHRAE winter conference papers · Cited by 128
Kim, N. H., Youn, B., & Webb, R. L. (1999) · Journal of Heat Transfer · doi:10.1115/1.2826030 · Cited by 125
Research works printed but not linked: 12
- H.M. Getu, Analysis of Low-temperature Supermarket Refrigeration Systems, ME thesis, The University of Auckland, Department of Mechanical Engineering, New Zealand, 2005.
- Faramarzi, 2002, Performance and energy impact of installing glass doors on an open vertical deli/dairy display case, ASHRAE Transactions, 108, 673
- Al-Mutawa, 1998, Determination of coil defrosting loads. Part IV: refrigeration/defrost cycle dynamics, ASHRAE Transactions, 104, 313
- H. Karata, Theoretically and Experimentally Investigation of a Domestic Refrigerator Evaporator, MSc thesis, Technical University of Istanbul–Institute of Science and Technology, Istanbul, 1995.
- O'Neal, 1985, A review of frost formation in simple geometries, ASHRAE Transactions, 91, 267
- R. Chandrasekharan, C.W. Bullard, Strategies for energy-efficient display case design, in: Proceedings of IIR Conference on Commercial Refrigeration, September 2005; Vicenza, Italy.
- Chandrasekharan, 2005, Design tool for display case evaporators, ASHRAE Transactions, 111, 1071
- Chaddock, 1966, Evaporation of refrigerant 12 in a horizontal tube with a constant wall heat flux, ASHRAE Transactions, 79, 90
- McQuiston, 1978, Correlation of heat, mass and momentum transfer coefficients for plate-fine-tube heat transfer surface with staggered tubes, ASHRAE Transactions, 84, 294
- Oskarsson, 1990, Evaporator model for operation with dry, wet, and frosted finned surface, Part I: heat transfer and fluid flow theory, ASHRAE Transactions, 96, 373
- Oskarsson, 1990, Evaporator model for operation with dry, wet, and frosted finned surface, Part II: evaporator models and verification, ASHRAE Transactions, 96, 381
- Krakow, 1990, A method for determining the effects of coil geometry and fan type on evaporator frosting, ASHRAE Transactions, 96, 393
Cited by
Thermodynamic analysis of an R744–R717 cascade refrigeration system
Getu, H. M., & Bansal, P. K. (2007) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2007.06.014 · Cited by 262
Self-citationA review – Status of CO2 as a low temperature refrigerant: Fundamentals and R&D opportunities
Bansal, P. K. (2011) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2011.12.006 · Cited by 156
Self-citationR744-R717 Cascade Refrigeration System: Performance Evaluation compared with a HFC Two-Stage System
Messineo, A. (2012) · Energy Procedia · doi:10.1016/j.egypro.2011.12.896 · Cited by 128
Dokandari, D. A., Hagh, A. S., & Mahmoudi, S. M. S. (2014) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2014.07.012 · Cited by 106
Analysis of energy savings in a supermarket refrigeration/HVAC system
Bahman, A. M., Rosario, L., & Rahman, M. M. (2012) · Applied Energy · doi:10.1016/j.apenergy.2012.02.043 · Cited by 68
Metadata
- Authors
- Getu, H. M., & Bansal, P. K.
- Affiliations
- University of Auckland (NZ)
- Corresponding author
- Bansal, P.K.
- Venue
- International Journal of Refrigeration
- Publisher
- Elsevier BV
- Published
- 2007-11
- Volume
- 30
- Issue
- 7
- Pages
- 1227-1243
- ISSN
- 0140-7007 (ISSN-L)
- OpenAlex
- W2065495844
- Semantic Scholar
- 1c69925d3c69ad39977124afe03f60702e2dc5a7
- Cited by
- 36
- References
- 37
- Citations by year
- 2025: 1 · 2024: 2 · 2022: 1 · 2021: 1 · 2020: 1 · 2019: 1 · 2018: 4 · 2017: 2 · 2016: 1 · 2015: 6 · 2014: 3 · 2013: 1 · 2012: 5
- FWCI
- 3.62
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- International Journal of Refrigeration (publishedVersion)
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
- Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
- Physical Sciences › Engineering › Mechanical Engineering › Adsorption and Cooling Systems
- Keywords
- evaporator, supermarket refrigeration, finned tube heat exchanger, frost formation, heat transfer coefficient, refrigerant mass flow rate, relative humidity, low-temperature refrigeration
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Modeling and performance analyses of evaporators in frozen-food supermarket display cabinets at low temperatures. https://app.cochat.ai/papers/10.1016/j.ijrefrig.2007.02.003
- The paper
- Getu, H. M., & Bansal, P. K. (2007). Modeling and performance analyses of evaporators in frozen-food supermarket display cabinets at low temperatures. International Journal of Refrigeration. https://doi.org/10.1016/j.ijrefrig.2007.02.003
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.