Experimental analysis of frost formation with the presence of an electric field on fin and tube evaporator
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Electric fields and ultrasonic vibrations disrupt the initial nucleation points, thereby decelerating frost formation.
“Meanwhile, the electric fields [27,28] and ultrasonic vibrations [29] have been applied disrupt the initial nucleation points, thereby decelerating frost formation.”
From Enhancing heat-exchanger performance in frost conditions via superhydrophobic surface modification (2024) · cites this paper as [28]
Frost suppression can be achieved without relying on external high-grade energy sources, thereby reducing energy consumption and equipment costs associated with frost suppression.
“Frost sup pression can be achieved without relying on external high-grade energy sources [25 -29], thereby reducing energy consumption and equipment costs associated with frost suppression.”
From Enhancing heat-exchanger performance in frost conditions via superhydrophobic surface modification (2024) · cites this paper as [28]
Cites
Study of frost properties correlating with frost formation types
Hayashi, Y., Aoki, A., Adachi, S., & Hori, K. (1977) · Journal of Heat Transfer · doi:10.1115/1.3450675 · Cited by 402 · see citing works
Xia, Y., Zhong, Y., Hrnjak, P. S., & Jacobi, A. M. (2006) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2006.03.005 · Cited by 148 · see citing works
Modeling non-uniform frost growth on a fin-and-tube heat exchanger
Padhmanabhan, S. K., Fisher, D. E., Cremaschi, L., & Moallem, E. (2011) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2011.06.005 · Cited by 66 · see citing works
Moallem, E., Padhmanabhan, S., Cremaschi, L., & Fisher, D. E. (2012) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2011.08.010 · Cited by 61 · see citing works
Characteristics of frost formation on two-dimensional fins and its empirical correlations
Kim, K., Kim, J.-S., & Lee, K.-S. (2010) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2010.02.043 · Cited by 25 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Amer, M., & Wang, C.-C. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.01.120 · Cited by 218 · see citing works
Wang, F., Zhou, Y., Yang, W., Ni, M., Zhang, X., & Liang, C. (2020) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2020.114967 · Cited by 60 · see citing works
A novel hybrid frost detection and defrosting system for domestic refrigerators
Malik, A. N., Khan, S. A., & Lazoglu, I. (2020) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2020.05.016 · Cited by 44 · see citing works
Sarmiento, A. P., de Sá Sarmiento, F. I. P., Shooshtari, A., & Ohadi, M. (2024) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2024.123680 · Cited by 29 · see citing works
Optimal defrost cycle for air coolers revisited: A study of fan-supplied tube-fin evaporators
da Silva, D. L., & Hermes, C. J. L. (2018) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2018.02.009 · Cited by 22 · see citing works
Enhancing heat-exchanger performance in frost conditions via superhydrophobic surface modification
He, H., Zhou, X., Lyu, N., Wang, F., Liang, C., & Zhang, X. (2024) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2024.122914 · Cited by 19 · see citing works
Wang, F., Xiang, M., & Yang, W. (2024) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2023.121881 · Cited by 20 · see citing works
- Authors
- Joppolo, C. M., Molinaroli, L., De Antonellis, S., & Merlo, U.
- Affiliations
- Politecnico di Milano (IT)
- Corresponding author
- Molinaroli, Luca
- Venue
- International Journal of Refrigeration
- Publisher
- Elsevier BV
- Published
- 2012-03
- Volume
- 35
- Issue
- 2
- Pages
- 468-474
- ISSN
- 0140-7007 (ISSN-L)
- OpenAlex
- W2073972230
- Cited by
- 53
- References
- 5
- Citations by year
- 2026: 3 · 2025: 6 · 2024: 6 · 2023: 7 · 2022: 3 · 2021: 6 · 2020: 6 · 2019: 3 · 2018: 3 · 2017: 5 · 2016: 2 · 2013: 3
- FWCI
- 1.70
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- International Journal of Refrigeration (publishedVersion)
- Virtual Community of Pathological Anatomy (University of Castilla La Mancha) (submittedVersion)
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
- Physical Sciences › Engineering › Aerospace Engineering › Icing and De-icing Technologies
- Physical Sciences › Engineering › Mechanics of Materials › Freezing and Crystallization Processes
- Keywords
- frost formation, DC electric field, air-side pressure drop, cooling capacity, air velocity, evaporation temperature
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review