Performance evaluation of air source heat pump under unnecessary defrosting phenomena for nine typical cities in China
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
As the frost layer thickens, the efficiency of ASHP can drop by 35-60%.
“As the frost layer thickens, the efficiency of ASHP can drop by 35 -60 % [31 -34]”
From Enhancing heat-exchanger performance in frost conditions via superhydrophobic surface modification (2024) · cites this paper as [32]
Cites
Experimental study on frost growth and dynamic performance of air source heat pump system
Guo, X.-M., Chen, Y.-G., Wang, W.-H., & Chen, C.-Z. (2008) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2008.01.007 · Cited by 173 · see citing works
Self-citationModeling for predicting frosting behavior of a fin–tube heat exchanger
Yang, D.-K., Lee, K.-S., & Song, S. (2006) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2005.09.022 · Cited by 94 · see citing works
Ge, Y., Sun, Y., Wang, W., Zhu, J., Li, L., & Liu, J. (2016) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2015.07.004 · Cited by 68 · see citing works
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Enhancing heat-exchanger performance in frost conditions via superhydrophobic surface modification
He, H., Zhou, X., Lyu, N., Wang, F., Liang, C., & Zhang, X. (2024) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2024.122914 · Cited by 19 · see citing works
- Authors
- Liu, J., Sun, Y., Wang, W., & Zhu, J.
- Affiliations
- Beijing University of Technology (CN)
- Corresponding author
- Wang, Wei
- Venue
- International Journal of Refrigeration
- Publisher
- Elsevier BV
- Published
- 2017-02
- Volume
- 74
- Pages
- 385-398
- ISSN
- 0140-7007 (ISSN-L)
- OpenAlex
- W2556016323
- Cited by
- 52
- References
- 3
- Citations by year
- 2026: 7 · 2025: 8 · 2024: 7 · 2023: 7 · 2022: 1 · 2021: 4 · 2020: 10 · 2019: 4 · 2018: 3 · 2017: 1
- FWCI
- 2.37
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- International Journal of Refrigeration (publishedVersion)
- Funders
- National Key Research and Development Program of China (2016YFC0700403)
- National Natural Science Foundation of China (51522801)
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
- Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
- Physical Sciences › Engineering › Mechanical Engineering › Adsorption and Cooling Systems
- Keywords
- air-source heat pump, energy loss, field testing, heating season, regional variation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review