Cited by 68Refrigeration and Air Conditioning TechnologiesBuilding Energy and Comfort OptimizationAdsorption and Cooling Systems

Field test study of a novel defrosting control method for air-source heat pumps by applying tube encircled photoelectric sensors

Ge, Yijing, Sun, Yuying, Wang, Wei, Zhu, Jiahe, Li, Lintao, Liu, Jingdong·2016·International Journal of Refrigeration

Integrity signals

Registry

Crossref · 10.1016/j.ijrefrig.2015.07.004

Cites

0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The optical signal conversion measurement method was developed based on photoelectric technology to monitor the degree of frosting on the outdoor heat exchanger surface of an ASHP unit.

    “In order to monitor the degree of frosting on the surface of the outdoor heat exchanger of an ASHP unit, the optical signal conversion measurement method was developed, based on photoelectric technology [112].”
  • The TEPS method transforms the difficult problem of monitoring frosting on the outdoor heat exchanger surface into measuring the degree of frosting in the test section.

    “Therefore, the difficult problem of monitoring the degree of frosting on the surface of the outdoor heat exchanger is cleverly transformed to measure the degree of frosting in the test section.”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Ge, Y., Sun, Y., Wang, W., Zhu, J., Li, L., & Liu, J.
Affiliations
Beijing University of Technology (CN)
Corresponding author
Wang, Wei
Venue
International Journal of Refrigeration
Publisher
Elsevier BV
Published
2016-06
Volume
66
Pages
133-144
ISSN
0140-7007 (ISSN-L)
OpenAlex
W1908376161
Cited by
68
References
24
Citations by year
2026: 3 · 2025: 7 · 2024: 7 · 2023: 10 · 2022: 7 · 2021: 7 · 2020: 6 · 2019: 7 · 2018: 8 · 2017: 3 · 2016: 3
FWCI
4.58
Type
journal article
Language
en
Open access
closed
Locations
International Journal of Refrigeration (publishedVersion)
Funders
  • National Natural Science Foundation of China (Grant No. 51178015)
  • National Twelfth Five-Year Science & Technology Support Plan (2011BAJ03B10)
  • Training Plan of Top-notch Talent Youth (Grant No. Q0004020201501)
  • New-Star of Science and Technology (Grant No. Z111106054511029)
  • Beijing Municipal Education Commission (KM 201410005022)
Topics
  • Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
  • Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
  • Physical Sciences › Engineering › Mechanical Engineering › Adsorption and Cooling Systems
Keywords
air-source heat pump, frost detection, compressor discharge temperature, heating capacity, field testing

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review