A novel characteristic index for frosting suppression based on the configuration and operation of air source heat pumps
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
As the frost layer thickens, the efficiency of ASHP can drop by 35-60%.
“As the frost layer thickens, the efficiency of ASHP can drop by 35 -60 % [31 -34]”
From Enhancing heat-exchanger performance in frost conditions via superhydrophobic surface modification (2024) · cites this paper as [31]
Cites
New model for frost growth rate
Na, B., & Webb, R. L. (2004) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2003.09.001 · Cited by 210 · see citing works
Frosting characteristics on hydrophobic and superhydrophobic surfaces: A review
Kim, M.-H., Kim, H., Lee, K.-S., & Kim, D. R. (2017) · Energy Conversion and Management · doi:10.1016/j.enconman.2017.01.067 · Cited by 171 · see citing works
Frost growth and densification in laminar flow over flat surfaces
Kandula, M. (2011) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2011.02.056 · Cited by 141 · see citing works
Performance of finned tube heat exchangers operating under frosting conditions
Yan, W.-M., Li, H.-Y., Wu, Y.-J., Lin, J.-Y., & Chang, W.-R. (2003) · International Journal of Heat and Mass Transfer · doi:10.1016/s0017-9310(02)00346-0 · Cited by 95 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Li, Z., Wei, W., Wang, W., Sun, Y., Wang, S., Lin, Y., Huang, C., & Deng, S. (2024) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2023.122136 · Cited by 30 · see citing works
Self-citationExperimental investigation on an air source heat pump system with a novel anti-frosting evaporator
Yu, S., Su, Y., Cai, W., & Qiu, G. (2023) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2022.119910 · Cited by 29 · see citing works
Enhancing heat-exchanger performance in frost conditions via superhydrophobic surface modification
He, H., Zhou, X., Lyu, N., Wang, F., Liang, C., & Zhang, X. (2024) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2024.122914 · Cited by 19 · see citing works
- Authors
- Liang, S., Wang, W., Sun, Y., Li, Z., Zhao, J., Lin, Y., & Deng, S.
- Affiliations
- Beijing University of Technology (CN)
- Hong Kong Polytechnic University (HK)
- Corresponding author
- Wang, Wei
- Venue
- International Journal of Refrigeration
- Publisher
- Elsevier BV
- Published
- 2020-01
- Volume
- 109
- Pages
- 161-171
- ISSN
- 0140-7007 (ISSN-L)
- OpenAlex
- W2980895312
- Cited by
- 53
- References
- 4
- Citations by year
- 2026: 9 · 2025: 12 · 2024: 8 · 2023: 10 · 2022: 6 · 2021: 4 · 2020: 4
- FWCI
- 1.97
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- International Journal of Refrigeration (publishedVersion)
- Funders
- National Key Research and Development Program of China (2016YFC0700400)
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
- Physical Sciences › Engineering › Mechanical Engineering › Adsorption and Cooling Systems
- Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
- Keywords
- air-source heat pump, characteristic index, temperature difference, space heating, heat pump operation, empirical correlations, frost formation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review