Ultralow-temperature refrigeration systems: Configurations and refrigerants to reduce the environmental impact
The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
Several environmental protection policies have been enforced restricting working fluids with high global warming potential (GWP) values used in many types of refrigeration and heat pump systems. However, ultralow-temperature (ULT) refrigeration has not been included, which commonly uses refrigerants with very high GWP values (such as R23 and R508B). Therefore, publicly available research programs seeking low GWP alternative refrigerants do not cover this application and the transition to more environmentally friendly fluids is slowed down. This work presents a comprehensive review that summarizes and discusses the available studies about ULT refrigeration systems. The current status of the technology, system architectures and refrigerants are analyzed. Moreover, the transition towards low GWP refrigerants is proposed, presenting the most promising low GWP alternatives. The most commonly used architectures for ULT refrigeration are the two-stage cascade and auto-cascade, in which the use of ejector has recently been considered in research papers. R170 and R1150 are the available natural refrigerants suitable for ULT, but they have not yet been included in many flammability and risk assessment studies. The A2 hydrofluoroolefin R1132a has been recently proposed as a blend component to avoid problems of stability. However, more information is still necessary to start with simulation and experimental studies. R41 could be an alternative due to its low GWP and suitable normal boiling point, but it has not been thoroughly investigated yet. Overall, there is a gap in the literature in terms of developing alternative refrigerants for ULT refrigeration. This study aims at shedding light on this gap to direct future research in this field towards reliable, environmentally friendly and marketable alternative refrigerants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Anthropogenic and Natural Radiative Forcing
(2014) · Climate Change 2013 – The Physical Science Basis · doi:10.1017/cbo9781107415324.018 · Cited by 3,683
NIOSH pocket guide to chemical hazards
Barsan, M. E. (2007) · Cited by 1,125
The next generation of refrigerants – Historical review, considerations, and outlook
Calm, J. M. (2008) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2008.01.013 · Cited by 834
Montreal Protocol on Substances that Deplete the Ozone Layer
Benedick (1996) · International Negotiation · doi:10.1163/15718069620847781 · Cited by 809
Limited options for low-global-warming-potential refrigerants
McLinden, M. O., Brown, J. S., Brignoli, R., Kazakov, A. F., & Domanski, P. A. (2017) · Nature Communications · doi:10.1038/ncomms14476 · Cited by 541
Natural and synthetic refrigerants, global warming: A review
Abas, N., Kalair, A. R., Khan, N., Haider, A., Saleem, Z., & Saleem, M. S. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2018.03.099 · Cited by 486
A thermodynamic analysis of refrigerants: Possibilities and tradeoffs for Low-GWP refrigerants
McLinden, M. O., Kazakov, A. F., Steven Brown, J., & Domanski, P. A. (2014) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2013.09.032 · Cited by 388
Hydrocarbons as refrigerants in small heat pump and refrigeration systems – A review
Palm, B. E. (2007) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2007.11.016 · Cited by 270
Harby, K. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.02.039 · Cited by 249
Thermodynamic analysis of an R744–R717 cascade refrigeration system
Getu, H. M., & Bansal, P. K. (2007) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2007.06.014 · Cited by 216
Sarbu, I. (2014) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2014.04.023 · Cited by 202
Mota-Babiloni, A., Makhnatch, P., & Khodabandeh, R. (2017) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2017.06.026 · Cited by 196
Self-citationNot-in-kind cooling technologies: A quantitative comparison of refrigerants and system performance
Qian, S., Nasuta, D., Rhoads, A., Wang, Y., Geng, Y., Hwang, Y., Radermacher, R., & Takeuchi, I. (2015) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2015.10.019 · Cited by 194
Enhancements in domestic refrigeration, approaching a sustainable refrigerator – A review
Belman-Flores, J. M., Barroso-Maldonado, J. M., Rodríguez-Muñoz, A. P., & Camacho-Vázquez, G. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.07.003 · Cited by 161
Velders, G. J. M., Fahey, D. W., Daniel, J. S., Andersen, S. O., & McFarland, M. (2015) · Atmospheric Environment · doi:10.1016/j.atmosenv.2015.10.071 · Cited by 157
Mota-Babiloni, A., Navarro-Esbrí, J., Makhnatch, P., & Molés, F. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.05.216 · Cited by 154
Self-citationCommercial refrigeration – An overview of current status
Mota-Babiloni, A., Navarro-Esbrí, J., Barragán-Cervera, Á., Molés, F., Peris, B., & Verdú, G. (2015) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2015.04.013 · Cited by 138
Self-citationKılıçarslan, A., & Hoşöz, M. (2010) · Energy Conversion and Management · doi:10.1016/j.enconman.2010.06.037 · Cited by 131
Eini, S., Shahhosseini, H. R., Delgarm, N., Lee, M., & Bahadori, A. (2016) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2016.07.013 · Cited by 127
Low-GWP refrigerants for medium and high-pressure applications
Domanski, P. A., Brignoli, R., Brown, J. S., Kazakov, A. F., & McLinden, M. O. (2017) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2017.08.019 · Cited by 124
An Investigation of R152a and Hydrocarbon Refrigerants in Mobile Air Conditioning
Ghodbane, M. (1999) · SAE technical papers on CD-ROM/SAE technical paper series · doi:10.4271/1999-01-0874 · Cited by 112
Kazakov, A., McLinden, M. O., & Frenkel, M. (2012) · Industrial & Engineering Chemistry Research · doi:10.1021/ie3016126 · Cited by 104
Mota-Babiloni, A., Mateu-Royo, C., Navarro-Esbrí, J., Molés, F., Amat-Albuixech, M., & Barragán-Cervera, Á. (2018) · Energy · doi:10.1016/j.energy.2018.09.188 · Cited by 101
Self-citationPredatory activity and spatial pattern: the response of generalist carabids to their aphid prey
WINDER, L., ALEXANDER, C. J., HOLLAND, J. M., SYMONDSON, W. O. C., PERRY, J. N., & WOOLLEY, C. (2005) · Journal of Animal Ecology · doi:10.1111/j.1365-2656.2005.00939.x · Cited by 98
Estimating refrigeration costs at cryogenic temperatures
Luyben, W. L. (2017) · Computers & Chemical Engineering · doi:10.1016/j.compchemeng.2017.03.013 · Cited by 80
Exergy analysis of multistage cascade low temperature refrigeration systems used in olefin plants
Mafi, M., Naeynian, S. M. M., & Amidpour, M. (2009) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2008.05.008 · Cited by 73
Refrigerant charge optimisation for propane heat pump water heaters
Ghoubali, R., Byrne, P., & Bazantay, F. (2017) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2017.02.017 · Cited by 65
Performance of R170 mixtures as refrigerants for refrigeration at −80 °C temperature range
Gong, M., Sun, Z., Wu, J., Zhang, Y., Meng, C., & Zhou, Y. (2008) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2008.11.007 · Cited by 61
Zhuang, X. R., Gong, M., Zou, X., Chen, G. F., & Wu, J. (2016) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2016.02.010 · Cited by 57
An experimental investigation on a modified cascade refrigeration system with an ejector
Li, Y., Yu, J., Qin, H., Sheng, Z., & Wang, Q. (2018) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2018.09.015 · Cited by 52
Performance analysis of an advanced ejector-expansion autocascade refrigeration cycle
Liu, Y., & Yu, J. (2018) · Energy · doi:10.1016/j.energy.2018.10.016 · Cited by 40
Visualization study on nucleate pool boiling of ethane, isobutane and their binary mixtures
Gong, M., Wu, Y., Li, D., Cheng, K., & Wu, J. (2013) · Experimental Thermal and Fluid Science · doi:10.1016/j.expthermflusci.2013.07.011 · Cited by 34
Evaluation of the impacts of high stage refrigerant charge on cascade heat pump performance
Chae, J.-H., & Choi, J. M. (2014) · Renewable Energy · doi:10.1016/j.renene.2014.07.042 · Cited by 34
Research trend of cascade heat pumps
Boahen, S., & Choi, J. (2017) · Science China Technological Sciences · doi:10.1007/s11431-016-9071-7 · Cited by 31
Economic and thermodynamic study of different cooling options: A review
Gupta, A., Anand, Y., Tyagi, S. K., & Anand, S. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.04.035 · Cited by 21
Sarkar, J., Bhattacharyya, S., & Lal, A. (2013) · International Journal of Sustainable Energy · doi:10.1080/14786451.2013.765426 · Cited by 20
Operational optimisation of centrifugal compressors in multilevel refrigeration cycles
Montanez-Morantes, M., Jobson, M., & Zhang, N. (2015) · Computers & Chemical Engineering · doi:10.1016/j.compchemeng.2015.11.006 · Cited by 20
Cited by
HFO refrigerants: A review of present status and future prospects.
Nair, V. (2021) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2020.10.039 · Cited by 192
Metadata
- Authors
- Mota-Babiloni, A., Mastani Joybari, M., Navarro-Esbrí, J., Mateu-Royo, C., Barragán-Cervera, Á., Amat-Albuixech, M., & Molés, F.
- Venue
- International Journal of Refrigeration
- Publisher
- Elsevier BV
- Published
- 2020-03
- Volume
- 111
- Pages
- 147-158
- ISSN
- 0140-7007 (ISSN-L)
- OpenAlex
- W2983713004
- Cited by
- 176
- References
- 38
- FWCI
- 7.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.