A novel hydrogen liquefaction process based on LNG cold energy and mixed refrigerant cycle
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
By storing normal H2 inside a tank, the conversion enthalpy is released in the tank and causes liquid H2 losses.
“By storing normal H2 inside a tank, the conversion enthalpy is released in the tank and causes the liquid H2 losses.101,152”
From Strategies To Improve the Performance of Hydrogen Storage Systems by Liquefaction Methods: A Comprehensive Review (2023) · cites this paper as [152]
The ortho- to para-H2 conversion appears with a transition from the ortho triplet state to a para singlet state, which in the normal state is very slow.
“The ortho- to para-H2 conversion appears with a transition from the ortho triplet state to a para singlet state, which in the normal state of this transition is very slow, and more time is spent in this process.101,152,153”
From Strategies To Improve the Performance of Hydrogen Storage Systems by Liquefaction Methods: A Comprehensive Review (2023) · cites this paper as [152]
No citation lists for this paper
No citation lists for this paper yet — checked again daily.
References 65 · Cited by 140
- Authors
- Faramarzi, S., Nainiyan, S. M. M., Mafi, M., & Ghasemiasl, R.
- Affiliations
- Islamic Azad University, Tehran (IR)
- Imam Khomeini International University (IR)
- Corresponding author
- Nainiyan, Seyed Mojtaba Mousavi
- Venue
- International Journal of Refrigeration
- Publisher
- Elsevier BV
- Published
- 2021-11
- Volume
- 131
- Pages
- 263-274
- ISSN
- 0140-7007 (ISSN-L)
- OpenAlex
- W3183607055
- Cited by
- 140
- References
- 65
- Citations by year
- 2026: 25 · 2025: 33 · 2024: 36 · 2023: 32 · 2022: 12 · 2021: 2
- FWCI
- 10.58
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- International Journal of Refrigeration (publishedVersion)
- Topics
- Physical Sciences › Engineering › Aerospace Engineering › Spacecraft and Cryogenic Technologies
- Physical Sciences › Engineering › Mechanical Engineering › Thermodynamic and Exergetic Analyses of Power and Cooling Systems
- Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
- Keywords
- hydrogen liquefaction, liquefied natural gas, LNG cold energy recovery, mixed refrigerant cycle, steam methane reforming, precooling, exergy analysis, energy consumption, economic analysis, payback period, liquid hydrogen production
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review