Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 414

The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.

A Randomized Phase 2 Study Comparing 2 Stereotactic Body Radiation Therapy Schedules for Medically Inoperable Patients With Stage I Peripheral Non-Small Cell Lung Cancer: NRG Oncology RTOG 0915 (NCCTG N0927)

Open access
Videtic, Gregory M.M., Hu, Chen, Singh, Anurag K., Chang, Joe Y., Parker, William, Olivier, Kenneth R., Schild, Steven E., Komaki, Ritsuko, Urbanic, James J., Choy, Hak·2015·International Journal of Radiation Oncology*Biology*Physics

Abstract

Purpose To compare 2 stereotactic body radiotherapy (SBRT) schedules for medically inoperable early-stage lung cancer to determine which produces the lowest rate of grade ≥ 3 protocol-specified adverse events (psAEs) at 1 year. Methods Patients with biopsy-proven peripheral (greater than 2 cm from the central bronchial tree) T1/T2, N0 (clinically node negative by positron emission tomography), M0 tumors were eligible. Patients were randomized to receive either 34 Gy in one fraction (Arm 1) or 48 Gy in 4 consecutive daily fractions (Arm 2). Rigorous central accreditation and quality assurance confirmed treatment per protocol guidelines. This study was designed to detect a psAEs rate > 17% at a 10% significance level (1-sided) and 90% power. Secondary endpoints included rates of primary tumor control (PC), overall survival (OS) and disease-free survival (DFS) at 1 year. Designating the better of the two regimens was based on pre-specified rules of psAEs and PC for each Arm. Results Ninety four patients were accrued between September 2009 and March 2011. Median follow up time was 30.2 months. Of 84 analyzable patients, 39 were in Arm 1 and 45 in Arm 2. Patient and tumor characteristics were balanced between Arms. Four (10.3%) patients on Arm 1 (95% confidence interval (CI): 2.9%-24.2%) and six (13.3%) patients on Arm 2 (95% CI: 5.1%-26.8%) experienced psAEs. The 2-year OS rate was 61.3% (95% CI: 44.2%-74.6%) for Arm 1 patients and 77.7% (95% CI: 62.5%-87.3%) for Arm 2. The 2-year DFS was 56.4% (95% 39.6%-70.2%) for Arm 1 and 71.1% (95% CI: 55.5%-82.1%) for Arm 2. The 1-year PC rate was 97.0% (95% CI: 84.2%-99.9%) for Arm 1 and 92.7% (80.1%-98.5%) for Arm 2. Conclusions 34 Gy in 1 fraction met pre-specified criteria and of the two schedules, warrants further clinical research.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ijrobp.2015.07.2260

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 18 references

Cited by

See all 414

Metadata

Authors
Videtic, G. M. M., Hu, C., Singh, A. K., Chang, J. Y., Parker, W., Olivier, K. R., Schild, S. E., Komaki, R., Urbanic, J. J., & Choy, H.
Venue
International Journal of Radiation Oncology*Biology*Physics
Publisher
Elsevier BV
Published
2015-11
Volume
93
Issue
4
Pages
757-764
ISSN
0360-3016 (ISSN-L)
OpenAlex
W2131441386
Cited by
414
References
18
FWCI
26.88
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Randomized Phase 2 Study Comparing 2 Stereotactic Body Radiation Therapy Schedules for Medically Inoperable Patients With Stage I Peripheral Non-Small Cell Lung Cancer: NRG Oncology RTOG 0915 (NCCTG N0927). https://app.cochat.ai/papers/10.1016/j.ijrobp.2015.07.2260
The paper
Videtic, G. M. M., Hu, C., Singh, A. K., Chang, J. Y., Parker, W., Olivier, K. R., Schild, S. E., Komaki, R., Urbanic, J. J., & Choy, H. (2015). A Randomized Phase 2 Study Comparing 2 Stereotactic Body Radiation Therapy Schedules for Medically Inoperable Patients With Stage I Peripheral Non-Small Cell Lung Cancer: NRG Oncology RTOG 0915 (NCCTG N0927). International Journal of Radiation Oncology*Biology*Physics. https://doi.org/10.1016/j.ijrobp.2015.07.2260

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.