The DOI matches its Crossref record.
Electrochromic dynamic windows for office buildings
Open accessAbstract
The next generation of advanced fenestration products includes dynamic electrochromic (EC) windows which can modulate the solar energy entering a building by application of an applied voltage. The windows can be switched from 62% visible transmittance (Tvis), 0.47 solar heat gain coefficient (SHGC) to a fully tinted state with ⩽2% Tvis, 0.09 SHGC. EC windows save energy in buildings – the total energy use for an eight story ASHRAE 90.1 2007 commercial office building with EC windows was modeled using the eQuest building simulation program and compared with the energy use of the same building with a variety of static glazings. The simulations were carried out in three US climate zones, encompassing a broad range of environmental exposure conditions from hot and dry (Arizona) to very cold (Minnesota). For all climate zones, building energy savings with EC glass were ⩾45% when compared to single pane static glazings common in existing building stock. When EC glass was compared to ASHRAE 90.1 2007 code compliant glazings, energy savings greater than 20% were calculated for the same building configuration. Optimum EC window control and performance strategies were derived from the modeling results. The EC glass and dimmable electric lights were synergistically controlled to maximize the use of natural daylighting and minimize electricity for lighting. Since EC glass can tint to ⩽2%, shades and/or blinds are not required for glare reduction, and building occupants always have a comfortable working environment and an unobstructed view and connection to the outdoors. All static glazing systems were assumed to have manual shading devices that are pulled by building occupants when glare becomes uncomfortable. For integrated building control systems, the peak load is significantly reduced when dynamic glazings are part of the building envelope. Consequently, chiller costs are lower, and the upfront capital costs for new building construction are reduced. Another key benefit of EC glass, elucidated by the simulations is reduction of CO2 emissions. EC glass reduces peak load carbon emissions by as much as 35% in new construction and 50% in renovation projects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The role of window glazing on daylighting and energy saving in buildings
Hee, W. J., Alghoul, M. A., Bakhtyar, B., Elayeb, O., Shameri, M. A., Alrubaih, M. S., & Sopian, K. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.09.020 · Cited by 533
Emerging electrochemical energy conversion and storage technologies
Badwal, S. P. S., Giddey, S. S., Munnings, C., Bhatt, A. I., & Hollenkamp, A. F. (2014) · Frontiers in Chemistry · doi:10.3389/fchem.2014.00079 · Cited by 478
Active dynamic windows for buildings: A review
Casini, M. (2018) · Renewable Energy · doi:10.1016/j.renene.2017.12.049 · Cited by 406
Bhamare, D. K., Rathod, M. K., & Banerjee, J. (2019) · Energy and Buildings · doi:10.1016/j.enbuild.2019.06.023 · Cited by 277
Ghosh, A., & Norton, B. (2018) · Renewable Energy · doi:10.1016/j.renene.2018.04.038 · Cited by 196
Metadata
- Authors
- Sbar, N. L., Podbelski, L., Yang, H. M., & Pease, B.
- Venue
- International Journal of Sustainable Built Environment
- Publisher
- Elsevier BV
- Published
- 2012-06
- Volume
- 1
- Issue
- 1
- Pages
- 125-139
- ISSN
- 2212-6090 (ISSN-L)
- OpenAlex
- W2034086138
- Cited by
- 232
- References
- 0
- FWCI
- 8.92
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrochromic dynamic windows for office buildings. https://app.cochat.ai/papers/10.1016/j.ijsbe.2012.09.001
- The paper
- Sbar, N. L., Podbelski, L., Yang, H. M., & Pease, B. (2012). Electrochromic dynamic windows for office buildings. International Journal of Sustainable Built Environment. https://doi.org/10.1016/j.ijsbe.2012.09.001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.