The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Passive cooling techniques for building and their applicability in different climatic zones—The state of art
Abstract
Abstract Building energy consumption is a vital component of the global energy mandate. A major part of the building energy is consumed in providing thermal comfort to occupants. Passive cooling techniques can be a promising alternative to satisfy the cooling requirements of the building as well as to reduce the building energy consumption. Selection of suitable passive cooling technique is dependent on many factors, including climatic conditions, building space constraints and performance of the passive technique. Thus, in order to adopt a suitable passive cooling technique for a given building, a thorough knowledge of different passive cooling techniques along with their applications and performance parameters is necessary. The objective of this article is to provide a comprehensive review on passive cooling techniques along with its classification, working, applications, recent developments and to analyze the influence of significant parameters such as building cooling load and indoor temperature on the performance of passive cooling techniques. The review establishes that passive cooling techniques have the potential to maintain the indoor temperature within comfort range while reducing the building cooling load.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Review of simulation modeling for shading devices in buildings
Kirimtat, A., Koyunbaba, B. K., Chatzikonstantinou, I., & Sariyildiz, S. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.08.020 · Cited by 351
Kuznik, F., Virgone, J., & Johannes, K. (2011) · Renewable Energy · doi:10.1016/j.renene.2010.11.008 · Cited by 213
A study of a polymer-based radiative cooling system
Meir, M. G., Rekstad, J. B., & LØvvik, O. M. (2002) · Solar Energy · doi:10.1016/s0038-092x(03)00019-7 · Cited by 125
Cooling load reduction of buildings using passive roof options
Raeissi, S., & Taheri, M. (1996) · Renewable Energy · doi:10.1016/0960-1481(95)00123-9 · Cited by 31
Research works printed but not linked: 226
- Agencia Internacional de la Energía. World Energy Outlook 2017. Int ENERGY AGENCY Together Secur Sustain 2017; Executive: 13. doi:10.1016/0301-4215(73)90024-4. · DOI
- Santamouris, 2013, Passive cooling dissipation techniques for buildings and other structures: the state of the art, Energy Build., 57, 74, 10.1016/j.enbuild.2012.11.002 · DOI · Paper page
- N.B. Geetha, R. Velraj, Passive cooling methods for energy efficient buildings with and without thermal energy storage – a review 2012;29:913–46.
- Prieto, 2017, 25 Years of cooling research in office buildings: review for the integration of cooling strategies into the building façade (1990 – 2014), Renew. Sustain. Energy Rev., 71, 89, 10.1016/j.rser.2017.01.012 · DOI
- Panchabikesan, 2017, Passive cooling potential in buildings under various climatic conditions in India, Renew. Sustain. Energy Rev., 78, 1236, 10.1016/j.rser.2017.05.030 · DOI
- Alizadeh, 2016, Development of free cooling based ventilation technology for buildings: thermal energy storage (TES) unit, performance enhancement techniques and design considerations – a review, Renew. Sustain. Energy Rev., 58, 619, 10.1016/j.rser.2015.12.168 · DOI
- Souayfane, 2016, Phase change materials (PCM) for cooling applications in buildings: a review, Energy Build., 129, 396, 10.1016/j.enbuild.2016.04.006 · DOI · Paper page
- Akeiber, 2016, A review on phase change material (PCM) for sustainable passive cooling in building envelopes, Renew. Sustain. Energy Rev., 60, 1470, 10.1016/j.rser.2016.03.036 · DOI · Paper page
- Lu, 2016, Cooling potential and applications prospects of passive radiative cooling in buildings: the current state-of-the-art, Renew. Sustain. Energy Rev., 65, 1079, 10.1016/j.rser.2016.07.058 · DOI · Paper page
- Chan, 2010, Review of passive solar heating and cooling technologies, Renew. Sustain. Energy Rev., 14, 781, 10.1016/j.rser.2009.10.030 · DOI · Paper page
- Duan, 2012, Indirect evaporative cooling: past, present and future potentials, Renew. Sustain. Energy Rev., 16, 6823, 10.1016/j.rser.2012.07.007 · DOI · Paper page
- Oropeza-perez, 2018, Active and passive cooling methods for dwellings: a review, Renew. Sustain. Energy Rev., 82, 531, 10.1016/j.rser.2017.09.059 · DOI
- Jomehzadeh, 2017, A review on windcatcher for passive cooling and natural ventilation in buildings, Part 1: indoor air quality and thermal comfort assessment, Renew. Sustain. Energy Rev., 70, 736, 10.1016/j.rser.2016.11.254 · DOI
- Goudarzi, 2017, Energy saving evaluation of passive systems for residential buildings in hot and dry regions, Renew Sustain Energy Rev, 68, 432, 10.1016/j.rser.2016.10.002 · DOI
- Hughes, 2011, A review of sustainable cooling technologies in buildings, Renew. Sustain. Energy Rev., 15, 3112, 10.1016/j.rser.2011.03.032 · DOI
- Konstantoglou, 2016, Dynamic operation of daylighting and shading systems: a literature review, Renew. Sustain. Energy Rev., 60, 268, 10.1016/j.rser.2015.12.246 · DOI
- Tejero-González, 2016, Assessing the applicability of passive cooling and heating techniques through climate factors: an overview, Renew. Sustain. Energy Rev., 65, 727, 10.1016/j.rser.2016.06.077 · DOI
- B. Raji, M.J. Tenpierik, van den A. Dobbelsteen, The impact of greening systems on building energy performance: a literature review n.d.:1–25.
- Meier, 1990, Strategic landscaping and air-conditioning savings: a literature review, Energy Build., 15, 479, 10.1016/0378-7788(90)90024-D · DOI
- Hsieh, 2018, Effects of tree shading and transpiration on building cooling energy use, Energy Build., 159, 382, 10.1016/j.enbuild.2017.10.045 · DOI
- Berry, 2013, Tree canopy shade impacts on solar irradiance received by building walls and their surface temperature, Build. Environ., 69, 91, 10.1016/j.buildenv.2013.07.009 · DOI
- M. Fairuz, P.J. Jones, J. Gwilliam, E. Salleh, An evaluation of outdoor and building environment cooling achieved through combination modification of trees with ground materials 2012;58. · DOI
- Pandit, 2010, Energy savings from tree shade, Ecol. Econ., 69, 1324, 10.1016/j.ecolecon.2010.01.009 · DOI
- J.R. Simpson, Improved estimates of tree-shade effects on residential energy use 2002;34. · DOI
- H. Akbari, M. Pomerantz, H. Taha, Cool surfaces and shade trees to reduce energy use and improve air quality in urban areas 2001;70:295–310. · DOI · Paper page
- D. Holm, Thermal improvement by means of leaf cover on external walls - a simulation model 1989;14:19–30. · DOI
- Nahar, 1999, Studies on solar passive cooling techniques for arid areas., Energy Convers. Manag., 40, 89, 10.1016/S0196-8904(98)00039-9 · DOI
- Tiwari, 1982, A review-Cooling by water evaporation over roof, Energy Convers. Manag., 22, 143, 10.1016/0196-8904(82)90036-X · DOI
- Sharifi, 2015, Roof ponds as passive heating and cooling systems: a systematic review, Appl. Energy, 160, 336, 10.1016/j.apenergy.2015.09.061 · DOI
- Spanaki, 2011, On the selection and design of the proper roof pond variant for passive cooling purposes, Renew. Sustain. Energy Rev., 15, 3523, 10.1016/j.rser.2011.05.007 · DOI
- Esparza, 2018, Potential of a wet fabric device as a roof evaporative cooling solution: mathematical and experimental analysis, J. Build. Eng., 19, 366, 10.1016/j.jobe.2018.05.021 · DOI
- Vorster, 2011, Sustainable cooling alternatives for buildings, J. Energy S. Afr., 22, 48, 10.17159/2413-3051/2011/v22i4a3229 · DOI
- Kharrufa, 2008, Roof pond cooling of the buildings in hot arid climates, Build. Environ., 43, 82, 10.1016/j.buildenv.2006.11.034 · DOI
- Runsheng, 2003, Experimental studies on a novel roof pond configuration for the cooling of the buildings, Renew. Energy, 28, 1513, 10.1016/S0960-1481(03)00002-8 · DOI
- Sodha, 1980, Periodic theory of an open roof pond, Appl. Energy, 7, 305, 10.1016/0306-2619(80)90005-7 · DOI
- Santamouris, 1996, Passive cooling of the buildings, Science
- Lee, 2013, Optimization of the building window system in Asian regions by analyzing solar heat gain and daylighting elements, Renew. Energy, 50, 522, 10.1016/j.renene.2012.07.029 · DOI · Paper page
- Hee, 2015, The role of window glazing on daylighting and energy saving in buildings, Renew. Sustain. Energy Rev., 42, 323, 10.1016/j.rser.2014.09.020 · DOI · Paper page
- Manz, 2008, On minimizing heat transport in architectural glazing, Renew. Energy, 33, 119, 10.1016/j.renene.2007.01.007 · DOI
- Eames, 2008, Vacuum glazing: current performance and future prospects, Vacuum, 82, 717, 10.1016/j.vacuum.2007.10.017 · DOI
- Fang, 2007, Low emittance coatings and the thermal performance of vacuum glazing, Sol. Energy, 81, 8, 10.1016/j.solener.2006.06.011 · DOI
- Kang, 2003, Manufacturing method for transparent electric windows using dye-sensitized TiO2 solar cells, Sol. Energy Mater. Sol. Cells, 75, 475, 10.1016/S0927-0248(02)00202-7 · DOI
- Kumara, 2017, Recent progress and utilization of natural pigments in dye sensitized solar cells: a review, Renew. Sustain. Energy Rev., 78, 301, 10.1016/j.rser.2017.04.075 · DOI · Paper page
- Baetens, 2011, Aerogel insulation for building applications: a state-of-the-art review, Energy Build., 43, 761, 10.1016/j.enbuild.2010.12.012 · DOI · Paper page
- Schultz, 2008, Evacuated aerogel glazings, Vacuum, 82, 723, 10.1016/j.vacuum.2007.10.019 · DOI
- Chiba, 2005, Low-emissivity coating of amorphous diamond-like carbon/Ag-alloy multilayer on glass, Appl. Surf. Sci., 246, 48, 10.1016/j.apsusc.2004.10.046 · DOI
- Reidinger, 2009, Low-emitting transparent coatings based on tin doped indiumoxide applied via a sol-gel routine, Thin Solid Films, 517, 3096, 10.1016/j.tsf.2008.11.078 · DOI
- Cuce, 2016, Toward multi-functional PV glazing technologies in low/zero carbon buildings: heat insulation solar glass - latest developments and future prospects, Renew. Sustain. Energy Rev., 60, 1286, 10.1016/j.rser.2016.03.009 · DOI
- Ng, 2014, Lifetime performance of semi-transparent building-integrated photovoltaic (BIPV) glazing systems in the tropics, Renew. Sustain. Energy Rev., 31, 736, 10.1016/j.rser.2013.12.044 · DOI
- Weber, 2012, Thermotropic glazings for overheating protection, Energy Procedia, 30, 471, 10.1016/j.egypro.2012.11.056 · DOI
- Nitz, 2005, Solar control with thermotropic layers, Sol. Energy, 79, 573, 10.1016/j.solener.2004.12.009 · DOI
- Cuce, 2015, A state-of-the-art review on innovative glazing technologies, Renew. Sustain. Energy Rev., 41, 695, 10.1016/j.rser.2014.08.084 · DOI
- Rezaei, 2017, A review of conventional, advanced, and smart glazing technologies and materials for improving indoor environment, Sol. Energy Mater. Sol. Cells, 159, 26, 10.1016/j.solmat.2016.08.026 · DOI · Paper page
- Tahmasebi, 2011, Assessment of the variation impacts of window on energy consumption and carbon footprint, Procedia Eng., 21, 820, 10.1016/j.proeng.2011.11.2083 · DOI
- Sbar, 2012, Electrochromic dynamic windows for office buildings, Int. J. Sustain. Built Environ., 1, 125, 10.1016/j.ijsbe.2012.09.001 · DOI
- Yao, 2012, Evaluation of indoor thermal environmental, energy and daylighting performance of thermotropic windows, Build. Environ., 49, 283, 10.1016/j.buildenv.2011.06.004 · DOI
- Chow, 2007, Performance evaluation of a PV ventilated window applying to office building of Hong Kong, Energy Build., 39, 643, 10.1016/j.enbuild.2006.09.014 · DOI
- Guo, 2012, Application of PV window foroffice building in hot summer and cold winter zone of China, Adv. Mater. Res., 347, 81
- Buratti, 2012, Experimental performance evaluation of aerogel glazing systems, Appl. Energy, 97, 430, 10.1016/j.apenergy.2011.12.055 · DOI
- Aǐnbinder, 1965, Klinicheskoe techenie pnevmokonizoa u invalidov-shakhterov kuzbassa (po materialam BTEK), Meditsina Tr I Promyshlennaya Ekol, 9, 43
- Littlefair, 2001, Daylight, sunlight and solar gain in the urban environment, Sol. Energy, 70, 177, 10.1016/S0038-092X(00)00099-2 · DOI
- Kim, 2012, Comparative advantage of an exterior shading device in thermal performance for residential buildings, Energy Build., 46, 105, 10.1016/j.enbuild.2011.10.040 · DOI · Paper page
- Gupta, 2016, Review of passive heating/cooling systems of the buildings, Energy Sci. Eng., 4, 305, 10.1002/ese3.129 · DOI
- Al-Masrani, 2018, Design optimisation of solar shading systems for tropical office buildings: challenges and future trends, Sol. Energy, 170, 849, 10.1016/j.solener.2018.04.047 · DOI
- Valladares-Rendón, 2017, Review on energy savings by solar control techniques and optimal building orientation for the strategic placement of façade shading systems, Energy Build., 140, 458, 10.1016/j.enbuild.2016.12.073 · DOI
- Claros, 2001, Indoor daylight climate-comparison between light shelves and overhang performances in Madrid for hours with unit sunshine fraction and realistic values of model reflectance, Sol. Energy, 71, 233, 10.1016/S0038-092X(01)00046-9 · DOI
- Meresi, 2016, Evaluating daylight performance of light shelves combined with external blinds in south-facing classrooms in Athens, Greece, Energy Build., 116, 190, 10.1016/j.enbuild.2016.01.009 · DOI
- Berardi, 2015, Analysis of the impacts of light shelves on the useful daylight illuminance in office buildings in Toronto, Energy Procedia, 78, 1793, 10.1016/j.egypro.2015.11.310 · DOI
- Mangkuto, 2018, Optimisation of daylight admission based on modifications of light shelf design parameters, J. Build. Eng., 18, 195, 10.1016/j.jobe.2018.03.007 · DOI
- David, 2011, Assessment of the thermal and visual efficiency of solar shades, Build. Environ., 46, 1489, 10.1016/j.buildenv.2011.01.022 · DOI
- Stazi, 2014, Comparison on solar shadings: monitoring of the thermo-physical behaviour, assessment of the energy saving, thermal comfort, natural lighting and environmental impact, Sol. Energy, 105, 512, 10.1016/j.solener.2014.04.005 · DOI
- Xiong, 2016, Model-based shading and lighting controls considering visual comfort and energy use, Sol. Energy, 134, 416, 10.1016/j.solener.2016.04.026 · DOI
- Yun, 2014, The influence of shading control strategies on the visual comfort and energy demand of office buildings, Energy Build., 84, 70, 10.1016/j.enbuild.2014.07.040 · DOI
- Sicurella, 2012, A statistical approach for the evaluation of thermal and visual comfort in free-running buildings, Energy Build., 47, 402, 10.1016/j.enbuild.2011.12.013 · DOI
- Cho, 1995, the Effect of Slat Angle of Windows With Venetian, Energy, 20, 1225, 10.1016/0360-5442(95)00074-Q · DOI
- Wong, 2007, A study of the effectiveness of passive climate control in naturally ventilated residential buildings in Singapore, Build. Environ., 42, 1395, 10.1016/j.buildenv.2005.11.032 · DOI
- Yu, 2008, Low-energy envelope design of residential building in hot summer and cold winter zone in China, Energy Build., 40, 1536, 10.1016/j.enbuild.2008.02.020 · DOI
- Yang, 1995, Energy conservation of the buildings in Taiwan, Pattern Recognit., 28, 1483, 10.1016/0031-3203(94)00153-D · DOI
- Ali Ahmed, 2012, Using simulation for studying the influence of vertical shading devices on the thermal performance of residential buildings (Case study: New Assiut City), Ain Shams Eng. J., 3, 163, 10.1016/j.asej.2012.02.001 · DOI
- Shen, 2014, Energy and visual comfort analysis of lighting and daylight control strategies, Build. Environ., 78, 155, 10.1016/j.buildenv.2014.04.028 · DOI
- Tzempelikos, 2007, The impact of shading design and control on building cooling and lighting demand, Sol. Energy, 81, 369, 10.1016/j.solener.2006.06.015 · DOI · Paper page
- R. Krishnan, Introduction to. Control 2014:2014. doi:10.1016/B978-0-240-81203-8.00002-7. · DOI
- Navarro, 2016, Thermal energy storage in building integrated thermal systems: a review. Part 2. Integration as passive system, Renew. Energy, 85, 1334, 10.1016/j.renene.2015.06.064 · DOI · Paper page
- Kosny, 2001, Thermal mass - energy savings potential in residential buildings, ORNL, 25
- Verbeke, 2018, Thermal inertia in buildings: a review of impacts across climate and building use, Renew. Sustain. Energy Rev., 82, 2300, 10.1016/j.rser.2017.08.083 · DOI · Paper page
- Rathod, 2013, Thermal stability of phase change materials used in latent heat energy storage systems: a review, Renew Sustain Energy Rev, 18, 246, 10.1016/j.rser.2012.10.022 · DOI · Paper page
- Hawes, 1993, Latent heat storage in building materials, Energy Build., 20, 77, 10.1016/0378-7788(93)90040-2 · DOI · Paper page
- Memon, 2014, Phase change materials integrated in building walls: a state of the art review, Renew. Sustain. Energy Rev., 31, 870, 10.1016/j.rser.2013.12.042 · DOI · Paper page
- Hariri, 1988, A review of thermal storage systems used in building applications, Build. Environ., 23, 1, 10.1016/0360-1323(88)90011-X · DOI
- Saffari, 2017, Passive cooling of the buildings with phase change materials using whole-building energy simulation tools: a review, Renew. Sustain. Energy Rev., 80, 1239, 10.1016/j.rser.2017.05.139 · DOI
- Kalnæs, 2015, Phase change materials and products for building applications: a state-of-the-art review and future research opportunities, Energy Build., 94, 150, 10.1016/j.enbuild.2015.02.023 · DOI · Paper page
- Zhou, 2012, Review on thermal energy storage with phase change materials (PCMs) in building applications, Appl. Energy, 92, 593, 10.1016/j.apenergy.2011.08.025 · DOI · Paper page
- Cabeza, 2011, Materials used as PCM in thermal energy storage in buildings: a review, Renew. Sustain. Energy Rev., 15, 1675, 10.1016/j.rser.2010.11.018 · DOI · Paper page
- Baetens, 2010, Phase change materials for building applications: a state-of-the-art review, Energy Build., 42, 1361, 10.1016/j.enbuild.2010.03.026 · DOI · Paper page
- Zhu, 2009, Dynamic characteristics and energy performance of the buildings using phase change materials: a review, Energy Convers. Manag., 50, 3169, 10.1016/j.enconman.2009.08.019 · DOI
- Sharma, 2009, Review on thermal energy storage with phase change materials and applications, Renew. Sustain. Energy Rev., 13, 318, 10.1016/j.rser.2007.10.005 · DOI · Paper page
- Pasupathy, 2008, Phase change material-based building architecture for thermal management in residential and commercial establishments, Renew. Sustain. Energy Rev., 12, 39, 10.1016/j.rser.2006.05.010 · DOI · Paper page
- Zhang, 2007, Application of latent heat thermal energy storage in buildings: State-of-the-art and outlook, II, Build. Environ., 42;6, 2197, 10.1016/j.buildenv.2006.07.023 · DOI · Paper page
- Tyagi, 2007, PCM thermal storage in buildings: a state of art, Renew. Sustain. Energy Rev., 11, 1146, 10.1016/j.rser.2005.10.002 · DOI · Paper page
- Zalba, 2003, Review on thermal energy storage with phase change: materials, heat transfer analysis and applications, Appl. Therm. Eng., 23, 251, 10.1016/S1359-4311(02)00192-8 · DOI · Paper page
- Xie, 2018, Thermal performance analysis of PCM wallboards for building application based on numerical simulation, Sol. Energy, 162, 533, 10.1016/j.solener.2018.01.069 · DOI
- Singh, 2018, Performance evaluation of dual phase change material gypsum board for the reduction of temperature swings in a building prototype in composite climate, Energy Build., 159, 191, 10.1016/j.enbuild.2017.10.097 · DOI
- Scalat, 1996, Full scale thermal testing of latent heat storage in wallboard, Sol. Energy Mater. Sol. Cells, 44, 49, 10.1016/0927-0248(96)00017-7 · DOI
- Neeper, 2000, Thermal dynamics of wallboard with latent heat storage, Sol. Energy, 68, 393, 10.1016/S0038-092X(00)00012-8 · DOI
- Kuznik, 2008, Energetic efficiency of room wall containing PCM wallboard: a full-scale experimental investigation, Energy Build., 40, 148, 10.1016/j.enbuild.2007.01.022 · DOI · Paper page
- Kuznik, 2009, Experimental investigation of wallboard containing phase change material: data for validation of numerical modeling, Energy Build., 41, 561, 10.1016/j.enbuild.2008.11.022 · DOI · Paper page
- Ahmad, 2006, Thermal testing and numerical simulation of a prototype cell using light wallboards coupling vacuum isolation panels and phase change material, Energy Build., 38, 673, 10.1016/j.enbuild.2005.11.002 · DOI
- Evola, 2014, Simulation of a ventilated cavity to enhance the effectiveness of PCM wallboards for summer thermal comfort in buildings, Energy Build., 70, 480, 10.1016/j.enbuild.2013.11.089 · DOI
- Diaconu, 2011, Thermal energy savings in buildings with PCM-enhanced envelope: influence of occupancy pattern and ventilation, Energy Build., 43, 101, 10.1016/j.enbuild.2010.08.019 · DOI
- Ascione, 2014, Energy refurbishment of existing buildings through the use of phase change materials: energy savings and indoor comfort in the cooling season, Appl. Energy, 113, 990, 10.1016/j.apenergy.2013.08.045 · DOI
- Shilei, 2007, Experimental study and evaluation of latent heat storagein phase change materials wallboards, Energy Build., 39, 1088, 10.1016/j.enbuild.2006.11.012 · DOI
- Koschenz, 2004, Development of a thermally activated ceiling panel with PCM for application in lightweight and retrofitted buildings, Energy Build., 36, 567, 10.1016/j.enbuild.2004.01.029 · DOI
- Wang, 2009, Performance of cooled-ceiling operating with MPCM slurry, Energy Convers. Manag., 50, 583, 10.1016/j.enconman.2008.10.021 · DOI
- A. Pasupathy, R. Velraj, Effect of double layer phase change material in building roof for year round thermal management 2008;40:193–203. doi:10.1016/j.enbuild.2007.02.016. · DOI
- Kosny, 2012, Field thermal performance of naturally ventilated solar roof with PCM heat sink, Sol. Energy, 86, 2504, 10.1016/j.solener.2012.05.020 · DOI
- Alawadhi, 2011, Building roof with conical holes containing PCM to reduce the cooling load: numerical study, Energy Convers. Manag., 52, 2958, 10.1016/j.enconman.2011.04.004 · DOI
- Roman, 2016, Simulating the effects of cool roof and PCM (phase change materials) based roof to mitigate UHI (urban heat island) in prominent US cities, Energy, 96, 103, 10.1016/j.energy.2015.11.082 · DOI
- A. Laura, V. Lucia, F. Cotana, Dynamic thermal-energy performance analysis of a prototype building with integrated phase change materials 2015;81:82–8. doi:10.1016/j.egypro.2015.12.062. · DOI
- Pisello, 2017, PCM for improving polyurethane-based cool roof membranes durability, Sol. Energy Mater. Sol. Cells, 160, 34, 10.1016/j.solmat.2016.09.036 · DOI
- Jayalath, 2016, Effects of phase change material roof layers on thermal performance of a residential building in Melbourne and Sydney, Energy Build., 121, 152, 10.1016/j.enbuild.2016.04.007 · DOI
- Weinläder, 2005, PCM-facade-panel for daylighting and room heating, Sol. Energy, 78, 177, 10.1016/j.solener.2004.04.013 · DOI
- Li, 2018, Simulation research on the dynamic thermal performance of a novel triple- glazed window filled with PCM, Sustain. Cities Soc., 40, 266, 10.1016/j.scs.2018.01.020 · DOI
- Hu, 2018, Energy & buildings a new ventilated window with PCM heat exchanger — performance analysis and design optimization, Energy Build., 169, 185, 10.1016/j.enbuild.2018.03.060 · DOI
- Ismail, 2008, Comparison between PCM filled glass windows and absorbing gas filled windows, Energy Build., 40, 710, 10.1016/j.enbuild.2007.05.005 · DOI
- Goia, 2013, Improving thermal comfort conditions by means of PCM glazing systems, Energy Build., 60, 442, 10.1016/j.enbuild.2013.01.029 · DOI
- Kolokotroni, 1998, Summer cooling with night ventilation for office buildings in moderate climates, Energy Build., 27, 231, 10.1016/S0378-7788(97)00048-0 · DOI
- Givoni, 1998, Effectiveness of mass and night ventilation in lowering the indoor daytime temperatures. Part I: 1993 experimental periods, Energy Build., 28, 25, 10.1016/S0378-7788(97)00056-X · DOI
- Zeinelabdein, 2018, Critical review of latent heat storage systems for free cooling in buildings, Renew. Sustain. Energy Rev., 82, 2843, 10.1016/j.rser.2017.10.046 · DOI
- Carrilho da Graça, 2002, Simulation of wind-driven ventilative cooling systems for an apartment building in Beijing and Shanghai, Energy Build., 34, 1, 10.1016/S0378-7788(01)00083-4 · DOI
- Fang, 2016, Preparation, microstructure and thermal properties of Mg-Bi alloys as phase change materials for thermal energy storage, Appl. Therm. Eng., 92, 187, 10.1016/j.applthermaleng.2015.09.090 · DOI
- Raj, 2010, Review on free cooling of the buildings using phase change materials, Renew. Sustain. Energy Rev., 14, 2819, 10.1016/j.rser.2010.07.004 · DOI
- Waqas, 2013, Phase change material (PCM) storage for free cooling of the buildings - a review, Renew. Sustain. Energy Rev., 18, 607, 10.1016/j.rser.2012.10.034 · DOI · Paper page
- Kamali, 2014, Review of free cooling system using phase change material for building, Energy Build., 80, 131, 10.1016/j.enbuild.2014.05.021 · DOI
- Thambidurai, 2015, Review on phase change material based free cooling of the buildings-the way toward sustainability, J. Energy Storage, 4, 74, 10.1016/j.est.2015.09.003 · DOI
- Turnpenny, 2000, Novel ventilation cooling system for reducing air conditioning in buildings.: part I: testing and theoretical modelling, Appl. Therm. Eng., 20, 1019, 10.1016/S1359-4311(99)00068-X · DOI
- Arkar, 2007, Efficiency of free cooling using latent heat storage integrated into the ventilation system of a low energy building, Int. J. Refrig., 30, 134, 10.1016/j.ijrefrig.2006.03.009 · DOI
- Waqas, 2011, Thermal performance of latent heat storage for free cooling of the buildings in a dry and hot climate: an experimental study, Energy Build., 43, 2621, 10.1016/j.enbuild.2011.06.015 · DOI
- Darzi, 2013, Numerical investigation of free-cooling system using plate type PCM storage, Int. Commun. Heat Mass Transf., 48, 155, 10.1016/j.icheatmasstransfer.2013.08.025 · DOI
- Mosaffa, 2013, Thermal performance optimization of free cooling systems using enhanced latent heat thermal storage unit, Appl. Therm. Eng., 59, 473, 10.1016/j.applthermaleng.2013.06.011 · DOI
- Daghigh, 2015, Assessing the thermal comfort and ventilation in Malaysia and the surrounding regions, Renew. Sustain. Energy Rev., 48, 682, 10.1016/j.rser.2015.04.017 · DOI
- Straw, 2000, Experimental measurements and computations of the wind-induced ventilation of a cubic structure, J. Wind Eng. Ind. Aerodyn., 88, 213, 10.1016/S0167-6105(00)00050-7 · DOI
- Mak, 2007, A numerical simulation of wing walls using computational fluid dynamics, Energy Build., 39, 995, 10.1016/j.enbuild.2006.10.012 · DOI
- Montero, 2001, Effect of ventilator configuration on wind-driven ventilation in a crop protection structure for the tropics, J. Agric. Eng. Res., 80, 99, 10.1006/jaer.2000.0694 · DOI
- Pfeiffer, 2008, Modelling of cowl performance in building simulation tools using experimental data and computational fluid dynamics, Build. Environ., 43, 1361, 10.1016/j.buildenv.2007.01.038 · DOI
- Khan, 2008, A review on wind driven ventilation techniques, Energy Build., 40, 1586, 10.1016/j.enbuild.2008.02.015 · DOI
- Calautit, 2016, A passive cooling wind catcher with heat pipe technology: CFD, wind tunnel and field-test analysis, Appl. Energy, 162, 460, 10.1016/j.apenergy.2015.10.045 · DOI
- Calautit, 2014, Integration and application of passive cooling within a wind tower for hot climates, HVAC R Res., 20, 722, 10.1080/10789669.2014.936795 · DOI
- Yik, 2010, Energy saving by utilizing natural ventilation in public housing in Hong Kong, Indoor Built Environ., 19, 73, 10.1177/1420326X09358021 · DOI
- Shanthi Priya, 2012, Experimental study on the thermal performance of a traditional house with one-sided wind catcher during summer and winter, Energy Effic., 5, 483, 10.1007/s12053-012-9155-9 · DOI
- Ghadiri, 2011, The effect of tower height in square plan wind catcher on its thermal behavior, Aust. J. Basic Appl. Sci., 5, 381
- Z. Ji, Y. Su, N. Khan, Performance evaluation and energy saving potential of windcatcher natural ventilation systems in China 2012;1:84–95. doi:10.7492/IJAEC.2012.010. · DOI
- Ismail, 2010, Comparison of different hybrid turbine ventilator (HTV) application strategies to improve the indoor thermal comfort, Int. J. Environ. Res., 4, 297
- Gao, 2011, Evaluating the influence of openings configuration on natural ventilation performance of residential units in Hong Kong, Build. Environ., 46, 961, 10.1016/j.buildenv.2010.10.029 · DOI
- Shetabivash, 2015, Investigation of opening position and shape on the natural cross ventilation, Energy Build., 93, 1, 10.1016/j.enbuild.2014.12.053 · DOI
- Evola, 2006, Computational analysis of wind driven natural ventilation in buildings, Energy Build., 38, 491, 10.1016/j.enbuild.2005.08.008 · DOI · Paper page
- Aflaki, 2015, A review on natural ventilation applications through building façade components and ventilation openings in tropical climates, Energy Build., 101, 153, 10.1016/j.enbuild.2015.04.033 · DOI · Paper page
- Hatamipour, 2008, Passive cooling systems in buildings: some useful experiences from ancient architecture for natural cooling in a hot and humid region, Energy Convers. Manag., 49, 2317, 10.1016/j.enconman.2008.01.018 · DOI
- Priyadarsini, 2004, Enhancement of natural ventilation in high-rise residential buildings using stack system, Energy Build., 36, 61, 10.1016/S0378-7788(03)00076-8 · DOI
- Prajongsan, 2012, Enhancing natural ventilation, thermal comfort and energy savings in high-rise residential buildings in Bangkok through the use of ventilation shafts, Build. Environ., 50, 104, 10.1016/j.buildenv.2011.10.020 · DOI
- Gratia, 2007, Guidelines for improving natural daytime ventilation in an office building with a double-skin facade, Sol. Energy, 81, 435, 10.1016/j.solener.2006.08.006 · DOI
- Saadatian, 2012, Trombe walls: a review of opportunities and challenges in research and development, Renew. Sustain. Energy Rev., 16, 6340, 10.1016/j.rser.2012.06.032 · DOI · Paper page
- Zamora, 2009, Thermal and dynamic optimization of the convective flow in trombe wall shaped channels by numerical investigation, Heat Mass Transf., 45, 1393, 10.1007/s00231-009-0509-6 · DOI
- Hu, 2017, A review on the application of Trombe wall system in buildings, Renew. Sustain. Energy Rev., 70, 976, 10.1016/j.rser.2016.12.003 · DOI
- Bodart, 2011, Architecture & sustainable development, Vol. 2
- Ji, 2007, PV-Trombe wall design for buildings in composite climates, J. Sol. Energy Eng., 129, 431, 10.1115/1.2770751 · DOI
- Peng, 2013, Investigation on the annual thermal performance of a photovoltaic wall mounted on a multi-layer façade, Appl. Energy, 112, 646, 10.1016/j.apenergy.2012.12.026 · DOI
- Abasova, 1972, Oligomerization of ethylene under the influence of bis-(π-allylnickel bromide) in conjunction with lewis acids, Bull. Acad Sci. USSR Div. Chem. Sci., 21, 608, 10.1007/BF00863224 · DOI
- Irshad, 2014, Energy and cost analysis of photo voltaic trombe wall system in tropical climate, Energy Procedia, 50, 71, 10.1016/j.egypro.2014.06.009 · DOI
- Stazi, 2012, Trombe wall management in summer conditions: an experimental study, Sol. Energy, 86, 2839, 10.1016/j.solener.2012.06.025 · DOI
- Ji, 2009, An improved approach for the application of Trombe wall system to building construction with selective thermo-insulation façades, Chin. Sci. Bull., 54, 1949, 10.1007/s11434-009-0353-6 · DOI
- Stazi, 2012, The behaviour of solar walls in residential buildings with different insulation levels: an experimental and numerical study, Energy Build., 47, 217, 10.1016/j.enbuild.2011.11.039 · DOI
- Li, 2014, Experimental study on thermal performance of a solar chimney combined with PCM, Appl. Energy, 114, 172, 10.1016/j.apenergy.2013.09.022 · DOI
- Saadatian, 2013, A state of the art review of solar walls: concepts and applications, J. Build. Phys., 37, 55, 10.1177/1744259113479336 · DOI
- Yang, 2000, Simple approach to cooling load component calculation through PV walls, Energy Build., 31, 285, 10.1016/S0378-7788(99)00041-9 · DOI
- Rabani, 2015, Empirical investigation of the cooling performance of a new designed Trombe wall in combination with solar chimney and water spraying system, Energy Build., 102, 45, 10.1016/j.enbuild.2015.05.010 · DOI
- Bacharoudis, 2007, Study of the natural convection phenomena inside a wall solar chimney with one wall adiabatic and one wall under a heat flux, Appl. Therm. Eng., 27, 2266, 10.1016/j.applthermaleng.2007.01.021 · DOI
- Miyazaki, 2006, The effects of solar chimneys on thermal load mitigation of office buildings under the Japanese climate, Renew. Energy, 31, 987, 10.1016/j.renene.2005.05.003 · DOI
- Shi, 2018, Determining the influencing factors on the performance of solar chimney in buildings, Renew. Sustain. Energy Rev., 88, 223, 10.1016/j.rser.2018.02.033 · DOI
- Monghasemi, 2018, A review of solar chimney integrated systems for space heating and cooling application, Renew. Sustain. Energy Rev., 81, 2714, 10.1016/j.rser.2017.06.078 · DOI
- Khedari, 2003, Field study performance of solar chimney with air-conditioned building, Energy, 28, 1099, 10.1016/S0360-5442(03)00092-6 · DOI
- Chungloo, 2007, Application of passive cooling systems in the hot and humid climate: the case study of solar chimney and wetted roof in Thailand, Build. Environ., 42, 3341, 10.1016/j.buildenv.2006.08.030 · DOI
- Punyasompun, 2009, Investigation on the application of solar chimney for multi-storey buildings, Renew. Energy, 34, 2545, 10.1016/j.renene.2009.03.032 · DOI
- Ramírez-Dávila, 2014, Numerical study of earth-to-air heat exchanger for three different climates, Energy Build., 76, 238, 10.1016/j.enbuild.2014.02.073 · DOI
- Rabani, 2014, Numerical simulation of an innovated building cooling system with combination of solar chimney and water spraying system, Heat Mass Transf., 50, 1609, 10.1007/s00231-014-1366-5 · DOI
- Amer, 2006, Passive options for solar cooling of the buildings in arid areas, Energy, 31, 1332, 10.1016/j.energy.2005.06.002 · DOI · Paper page
- Al-Jamal, 1994, Greenhouse cooling in hot countries, Energy, 1187, 10.1016/0360-5442(94)90075-2 · DOI
- Costelloe, 2003, Indirect evaporative cooling potential in air-water systems in temperate climates, Energy Build., 35, 573, 10.1016/S0378-7788(02)00161-5 · DOI
- Cuce, 2016, A state of the art review of evaporative cooling systems for building applications, Renew. Sustain. Energy Rev., 54, 1240, 10.1016/j.rser.2015.10.066 · DOI
- Riangvilaikul, 2010, An experimental study of a novel dew point evaporative cooling system, Energy Build., 42, 637, 10.1016/j.enbuild.2009.10.034 · DOI
- Daou, 2006, Desiccant cooling air conditioning: a review, Renew. Sustain. Energy Rev., 10, 55, 10.1016/j.rser.2004.09.010 · DOI · Paper page
- Fan, 2007, Review of solar sorption refrigeration technologies: development and applications, Renew. Sustain. Energy Rev., 11, 1758, 10.1016/j.rser.2006.01.007 · DOI · Paper page
- Dai, 2002, Theoretical study on a cross-flow direct evaporative cooler using honeycomb paper as packing material, Appl. Therm. Eng., 22, 1417, 10.1016/S1359-4311(02)00069-8 · DOI
- Camargo, 2005, Experimental performance of a direct evaporative cooler operating during summer in a Brazilian city, Int. J. Refrig., 28, 1124, 10.1016/j.ijrefrig.2004.12.011 · DOI
- Wu, 2009, Theoretical analysis on heat and mass transfer in a direct evaporative cooler, Appl. Therm. Eng., 29, 980, 10.1016/j.applthermaleng.2008.05.016 · DOI
- Wu, 2009, Numerical investigation on the heat and mass transfer in a direct evaporative cooler, Appl. Therm. Eng., 29, 195, 10.1016/j.applthermaleng.2008.02.018 · DOI
- Ibrahim, 2003, Performance of porous ceramic evaporators for building cooling application, Energy Build., 35, 941, 10.1016/S0378-7788(03)00019-7 · DOI
- Bishoyi, 2017, Experimental performance of a direct evaporative cooler in composite climate of India, Energy Build., 153, 190, 10.1016/j.enbuild.2017.08.014 · DOI
- Porumb, 2016, A review of indirect evaporative cooling operating conditions and performances, Energy Procedia, 85, 452, 10.1016/j.egypro.2015.12.226 · DOI
- Maheshwari, 2001, Energy-saving potential of an indirect evaporative cooler, Appl. Energy, 69, 69, 10.1016/S0306-2619(00)00066-0 · DOI
- Hajidavalloo, 2007, Application of evaporative cooling on the condenser of window-air-conditioner, Appl. Therm. Eng., 27, 1937, 10.1016/j.applthermaleng.2006.12.014 · DOI
200 of 226 shown
Cited by
Advances Toward a Net-Zero Global Building Sector
Ürge-Vorsatz, D., Khosla, R., Bernhardt, R., Chan, Y. C., Vérez, D., Hu, S., & Cabeza, L. F. (2020) · Annual Review of Environment and Resources · doi:10.1146/annurev-environ-012420-045843 · Cited by 250
Resilient cooling strategies – A critical review and qualitative assessment
Zhang, C., Kazanci, O. B., Levinson, R., Heiselberg, P., Olesen, B. W., Chiesa, G., Sodagar, B., Ai, Z., Selkowitz, S., Zinzi, M., et al. (2021) · Energy and Buildings · doi:10.1016/j.enbuild.2021.111312 · Cited by 180
Colelli, F. P., Wing, I. S., & Cian, E. D. (2023) · Scientific Reports · doi:10.1038/s41598-023-31469-z · Cited by 114
Sun, K., Zhang, W., Zeng, Z., Levinson, R., Wei, M., & Hong, T. (2021) · Energy and Buildings · doi:10.1016/j.enbuild.2021.111383 · Cited by 86
Metadata
- Authors
- Bhamare, D. K., Rathod, M. K., & Banerjee, J.
- Venue
- Energy and Buildings
- Publisher
- Elsevier BV
- Published
- 2019-09
- Volume
- 198
- Pages
- 467-490
- ISSN
- 0378-7788 (ISSN-L)
- OpenAlex
- W2951277102
- Cited by
- 277
- References
- 4
- FWCI
- 18.57
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Passive cooling techniques for building and their applicability in different climatic zones—The state of art. https://app.cochat.ai/papers/10.1016/j.enbuild.2019.06.023
- The paper
- Bhamare, D. K., Rathod, M. K., & Banerjee, J. (2019). Passive cooling techniques for building and their applicability in different climatic zones—The state of art. Energy and Buildings. https://doi.org/10.1016/j.enbuild.2019.06.023
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.