The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Medical image fusion using m-PCNN
Open accessAbstract
Medical image fusion plays an important role in clinical applications such as image-guided surgery, image-guided radiotherapy, non-invasive diagnosis, and treatment planning. Pulse coupled neural network (PCNN) is derived from the synchronous neuronal burst phenomena in the cat visual cortex. However, it is very difficult to directly apply original PCNN into the field of image fusion, because its model has some shortcomings. Although a significant amount of research work has been done in developing various medical image algorithms, one disadvantage with the approaches is that they cannot deal with different kinds of medical images. In this instance, we propose a novel multi-channel model -m-PCNN for the first time and apply it to medical image fusion. In the paper, firstly the mathematical model of m-PCNN is described, and then dual-channel model as a special case of m-PCNN is introduced in detail. In order to show that the m-PCNN can deal with multimodal medical images, we used four pairs of medical images with different modalities as our experimental subjects. At the same time, in comparison with other methods (Contrast pyramid, FSD pyramid, Gradient pyramid, Laplacian pyramid, etc.), the performance and relative importance of various methods is investigated using the Mutual Information criteria. Experimental results show our method outperforms other methods, in both visual effect and objective evaluation criteria.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Laplacian pyramid as a compact image code
Burt, P., & Adelson, E. (1983) · IEEE Transactions on Communications · doi:10.1109/tcom.1983.1095851 · Cited by 6,077
Cited by
Medical image fusion: A survey of the state of the art
James, A. P., & Dasarathy, B. V. (2014) · Information Fusion · doi:10.1016/j.inffus.2013.12.002 · Cited by 967
Yin, M., Liu, X., Liu, Y., & Chen, X. (2019) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2018.2838778 · Cited by 594
Azam, M. A., Khan, K. B., Salahuddin, S., Rehman, E., Khan, S. A., Khan, M. A., Kadry, S., & Gandomi, A. H. (2022) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2022.105253 · Cited by 449
A medical image fusion method based on convolutional neural networks
Liu, Y., Chen, X., Cheng, J., & Peng, H. (2017) · 2017 20th International Conference on Information Fusion (Fusion) · doi:10.23919/icif.2017.8009769 · Cited by 391
Multimodal medical image fusion review: Theoretical background and recent advances
Hermessi, H., Mourali, O., & Zagrouba, E. (2021) · Signal Processing · doi:10.1016/j.sigpro.2021.108036 · Cited by 301
Metadata
- Authors
- Wang, Z., & Ma, Y.
- Venue
- Information Fusion
- Publisher
- Elsevier BV
- Published
- 2008-04
- Volume
- 9
- Issue
- 2
- Pages
- 176-185
- ISSN
- 1566-2535 (ISSN-L)
- OpenAlex
- W1986231131
- Cited by
- 224
- References
- 1
- FWCI
- 14.80
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Medical image fusion using m-PCNN. https://app.cochat.ai/papers/10.1016/j.inffus.2007.04.003
- The paper
- Wang, Z., & Ma, Y. (2008). Medical image fusion using m-PCNN. Information Fusion. https://doi.org/10.1016/j.inffus.2007.04.003
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.