Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 167

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Bio-corrosion behavior and in vitro biocompatibility of equimolar TiZrHfNbTa high-entropy alloy

Yang, Wei, Liu, Ying, Pang, Shujie, Liaw, Peter K., Zhang, Tao · 2020 · Intermetallics

Abstract

Abstract Ti20Zr20Hf20Nb20Ta20 high-entropy alloy (TiZrHfNbTa HEA) is considered to be attractive for biomedical applications due to its good mechanical properties and composition that composed of biocompatible elements. In the present study, the bio-corrosion behavior in a simulated physiological environment and in vitro biocompatibility of the TiZrHfNbTa HEA were investigated in comparison with those of the Ti-6Al-4V alloy. It was found that the TiZrHfNbTa HEA exhibited as good bio-corrosion resistance as that of the Ti-6Al-4V alloy in the Hank's solution at 310 K, as revealed by the spontaneously-passivating behavior with a low passive current density of about 10−2 A/m2, a low corrosion rate in the order of 10−4 mm/year, and high electrochemical impedance of the HEA. X-ray photoelectron spectroscopy (XPS) analysis of the alloy surface suggested that the formation of the passive film composed of TiO2, ZrO2, HfO2, Nb2O5, and Ta2O5 is responsible for the high bio-corrosion resistance of the HEA. The good adhesion, viability and proliferation behaviors of MC3T3-E1 pre-osteoblasts on the TiZrHfNbTa HEA indicated its good in vitro biocompatibility. The combination of the good bio-corrosion resistance and in vitro biocompatibility demonstrates the potential of the TiZrHfNbTa HEA for biomedical applications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.intermet.2020.106845

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 167

Metadata

Authors
Yang, W., Liu, Y., Pang, S., Liaw, P. K., & Zhang, T.
Venue
Intermetallics
Publisher
Elsevier BV
Published
2020-09
Volume
124
Pages
106845
ISSN
0966-9795 (ISSN-L)
OpenAlex
W3035022220
Cited by
167
References
2
FWCI
8.57
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Bio-corrosion behavior and in vitro biocompatibility of equimolar TiZrHfNbTa high-entropy alloy. https://app.cochat.ai/papers/10.1016/j.intermet.2020.106845
The paper
Yang, W., Liu, Y., Pang, S., Liaw, P. K., & Zhang, T. (2020). Bio-corrosion behavior and in vitro biocompatibility of equimolar TiZrHfNbTa high-entropy alloy. Intermetallics. https://doi.org/10.1016/j.intermet.2020.106845

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.