The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Stationary wavelet transform based ECG signal denoising method
Abstract
Electrocardiogram (ECG) signals are used to diagnose cardiovascular diseases. During ECG signal acquisition, various noises like power line interference, baseline wandering, motion artifacts, and electromyogram noise corrupt the ECG signal. As an ECG signal is non-stationary, removing these noises from the recorded ECG signal is quite tricky. In this paper, along with the proposed denoising technique using stationary wavelet transform, various denoising techniques like lowpass filtering, highpass filtering, empirical mode decomposition, Fourier decomposition method, discrete wavelet transform are studied to denoise an ECG signal corrupted with noise. Signal-to-noise ratio, percentage root-mean-square difference, and root mean square error are used to compare the ECG signal denoising performance. The experimental result showed that the proposed stationary wavelet transform based ECG denoising technique outperformed the other ECG denoising techniques as more ECG signal components are preserved than other denoising algorithms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, N. E., Shen, Z., Long, S. R., Wu, M. C., Shih, H. H., Zheng, Q., Yen, N.-C., Tung, C. C., & Liu, H. H. (1998) · Proceedings of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rspa.1998.0193 · Cited by 23,564
Writing Committee Members, Antman, E. M., Anbe, D. T., Armstrong, P. W., Bates, E. R., Green, L. A., Hand, M., Hochman, J. S., Krumholz, H. M., Kushner, F. G., et al. (2004) · Circulation · doi:10.1161/01.cir.0000134791.68010.fa · Cited by 8,356
The impact of the MIT-BIH Arrhythmia Database
Moody, G. B., & Mark, R. G. (2001) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.932724 · Cited by 4,812
Adaptive noise cancelling: Principles and applications
Widrow, B., Glover, J. R., McCool, J. M., Kaunitz, J., Williams, C. S., Hearn, R. H., Zeidler, J. R., Eugene Dong, Jr., & Goodlin, R. C. (1975) · Proceedings of the IEEE · doi:10.1109/proc.1975.10036 · Cited by 3,939
ACC/AHA Guidelines for the Management of Patients With ST-Elevation Myocardial Infarction
Antman, E. M., Anbe, D. T., Armstrong, P. W., Bates, E. R., Green, L. A., Hand, M., Hochman, J. S., Krumholz, H. M., Kushner, F. G., Lamas, G. A., et al. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.07.014 · Cited by 1,302
Nutzung der EKG-Signaldatenbank CARDIODAT der PTB über das Internet
Bousseljot, R., Kreiseler, D., & Schnabel, A. (2009) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmte.1995.40.s1.317 · Cited by 623
Kaplan Berkaya, S., Uysal, A. K., Sora Gunal, E., Ergin, S., Gunal, S., & Gulmezoglu, M. B. (2018) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2018.03.003 · Cited by 610
Alberdi, A., Aztiria, A., & Basarab, A. (2016) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2015.11.007 · Cited by 473
ECG Signal Denoising By Wavelet Transform Thresholding
Alfaouri, M., & Daqrouq, K. (2008) · American Journal of Applied Sciences · doi:10.3844/ajassp.2008.276.281 · Cited by 398
Van Alste, J. A., & Schilder, T. S. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325514 · Cited by 367
Poungponsri, S., & Yu, X.-H. (2013) · Neurocomputing · doi:10.1016/j.neucom.2013.02.010 · Cited by 266
Empirical mode decomposition based ECG enhancement and QRS detection
Pal, S., & Mitra, M. (2012) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2011.10.012 · Cited by 256
Rakshit, M., & Das, S. (2018) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2017.09.020 · Cited by 198
Liang, H., Lin, Q.-H., & Chen, J. D. Z. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.855719 · Cited by 178
Singhal, A., Singh, P., Fatimah, B., & Pachori, R. B. (2019) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2019.101741 · Cited by 159
Lenis, G., Pilia, N., Loewe, A., Schulze, W. H. W., & Dössel, O. (2017) · Computational and Mathematical Methods in Medicine · doi:10.1155/2017/9295029 · Cited by 154
Choosing Wavelet Methods, Filters, and Lengths for Functional Brain Network Construction
Zhang, Z., Telesford, Q. K., Giusti, C., Lim, K. O., & Bassett, D. S. (2016) · PLoS ONE · doi:10.1371/journal.pone.0157243 · Cited by 132
Kumar, S., Panigrahy, D., & Sahu, P. K. (2018) · Journal of Applied Biomedicine · doi:10.1016/j.bbe.2018.01.005 · Cited by 117
Appathurai, A., Carol, J. J., Raja, C., Kumar, S. N., Daniel, A. V., Malar, A. J. G., Fred, A. L., & Krishnamoorthy, S. (2019) · Measurement · doi:10.1016/j.measurement.2019.02.040 · Cited by 94
Insect–Machine Interface Based Neurocybernetics
Bozkurt, A. Y., Gilmour, R. F., Sinha, A., Stern, D., & Lal, A. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2015460 · Cited by 86
Motion Artifact Removal in Ambulatory ECG Signal for Heart Rate Variability Analysis
Berwal, D., Vandana, C. R., Dewan, S., Jiji, C. V., & Baghini, M. S. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2939391 · Cited by 84
From Pacemaker to Wearable: Techniques for ECG Detection Systems
Kumar, A., Komaragiri, R., & Kumar, M. (2018) · Journal of Medical Systems · doi:10.1007/s10916-017-0886-1 · Cited by 81
Self-citationMotion Artifact Removal In Ecg Signals Using Multi-Resolution Thresholding
Muma, M., Strasser, F., & Zoubir, A. M. (2012) · Zenodo (CERN European Organization for Nuclear Research) · doi:10.5281/zenodo.42801 · Cited by 73
Kumar, A., Komaragiri, R., & Kumar, M. (2018) · ISA Transactions · doi:10.1016/j.isatra.2018.05.003 · Cited by 68
Self-citationDesign of wavelet transform based electrocardiogram monitoring system
Kumar, A., Komaragiri, R., & Kumar, M. (2018) · ISA Transactions · doi:10.1016/j.isatra.2018.08.003 · Cited by 67
Self-citationA review on ECG filtering techniques for rhythm analysis
Malghan, P. G., & Hota, M. K. (2020) · Research on Biomedical Engineering · doi:10.1007/s42600-020-00057-9 · Cited by 51
Motion artifact removal using cascade adaptive filtering for ambulatory ECG monitoring system
Kim, H., Kim, S., Helleputte, N. V., et al. (2012) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2012.6418472 · Cited by 49
Digital filtering with applications to electrocardiogram processing
Weaver, C. S., von der Groeben, J., Mantey, P. E., Toole, J., Cole, C., FitzGerald, J., & Lawrence, R. (1968) · IEEE Transactions on Audio and Electroacoustics · doi:10.1109/tau.1968.1161993 · Cited by 44
2009 IEEE Biomedical Circuits and Systems Conference
(2009) · doi:10.1109/biocas15685.2009 · Cited by 44
Kumar, A., Kumar, M., & Komaragiri, R. (2018) · Journal of Medical Systems · doi:10.1007/s10916-018-0953-2 · Cited by 42
Self-citationSahambi, J. S., Tandon, S. N., & Bhatt, R. K. P. (1997) · Medical & Biological Engineering & Computing · doi:10.1007/bf02510988 · Cited by 39
Mohebbian, M. R., Alam, M. W., Wahid, K. A., & Dinh, A. (2019) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2019.101673 · Cited by 36
Kumar, A., Komaragiri, R., & Kumar, M. (2019) · International Journal of Circuit Theory and Applications · doi:10.1002/cta.2667 · Cited by 34
Self-citationBerwal, D., Kumar, A., & Kumar, Y. (2018) · ISA Transactions · doi:10.1016/j.isatra.2018.08.002 · Cited by 31
Self-citationSparse ECG Denoising with Generalized Minimax Concave Penalty
Jin, Z., Dong, A., Shu, M., & Wang, Y. (2019) · Sensors · doi:10.3390/s19071718 · Cited by 30
Kumar, A., Berwal, D., & Kumar, Y. (2018) · Circuits Systems and Signal Processing · doi:10.1007/s00034-018-0754-3 · Cited by 27
Self-citationA novel low-complexity digital filter design for wearable ECG devices
Asgari, S., & Mehrnia, A. (2017) · PLoS ONE · doi:10.1371/journal.pone.0175139 · Cited by 23
Orlandic, L., Giovanni, E. D., Arza, A., Yazdani, S., Vésin, J.-M., & Atienza, D. (2019) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2019.8857226 · Cited by 22
Wireless 3-lead ECG system with on-board digital signal processing for ambulatory monitoring
Buxi, D., Berset, T., Hijdra, M., Tutelaers, M., Geng, D., Hulzink, J., van Noorloos, M., Romero, I., Torfs, T., & Helleputte, N. V. (2012) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2012.6418435 · Cited by 20
Metadata
- Authors
- Kumar, A., Tomar, H., Mehla, V. K., Komaragiri, R., & Kumar, M.
- Venue
- ISA Transactions
- Publisher
- Elsevier BV
- Published
- 2021-08
- Volume
- 114
- Pages
- 251-262
- ISSN
- 0019-0578 (ISSN-L)
- OpenAlex
- W3110800241
- Cited by
- 264
- References
- 39
- FWCI
- 16.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.