Adaptive neural fault-tolerant prescribed performance control of a rehabilitation exoskeleton for lower limb passive training
Abstract
This article studies the passive tracking problem of a wearable exoskeleton for lower limb rehabilitation therapy in the face of unmodeled dynamics, interactive friction, disturbance, prescribed performance constraints, and actuator faults. Adaptive neural networks and a smooth performance function are incorporated to establish a novel fault-tolerant tracking scheme, which can not only compensate for the nonlinear uncertainties and disturbance, but also handle the actuator fault with guaranteed tracking performance. A state feedback controller is presented by using the full state information and an output feedback controller is developed when the angular velocity is unavailable. The differential explosion issue of the backstepping technique is resolved by constructing a first-order filter and the unmeasurable velocity is estimated by a nonlinear observer. Semiglobal uniform boundedness stabilities of the exoskeleton system are proved via the Lyapunov direct method. The tracking performances of the designed control approaches are tested by comparative simulations.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
These considerations, integrated with standardized testing, ensure safe and ethical adoption across applications.
“These considerations, integrated with standardized testing [50], ensure safe and ethical adoption across applications.”
From Hybrid Fault-Tolerant Control in Cooperative Robotics: Advances in Resilience and Scalability (2025) · cites this paper as [50]
Standardized testing protocols at similar rates increase reliability across domains.
“and standardized testing protocols at similar rates increase reliability across domains [50].”
From Hybrid Fault-Tolerant Control in Cooperative Robotics: Advances in Resilience and Scalability (2025) · cites this paper as [50]
Cites
Xu, Z., Sun, C., Hu, X., Liu, Q., & Yao, J. (2023) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2023.3236114 · Cited by 113 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Hasan, S., & Alam, N. (2025) · Actuators · doi:10.3390/act14070342 · Cited by 27 · see citing works
“Key innovations and contributions in lower limb exoskeleton research reflect the field’s rapid progression toward more intelligent, adaptable, and user-centric systems.”
Hybrid Fault-Tolerant Control in Cooperative Robotics: Advances in Resilience and Scalability
Urrea, C. (2025) · Actuators · doi:10.3390/act14040177 · Cited by 19 · see citing works
“Bioinspired actuators, such as tensegrity designs with a 0.5 stiffness ratio, reduce downtime in agriculture [3], and standardized testing protocols at similar rates increase reliability across domains [50].”
InfluentialYang, Y., Chen, H., Huang, D.-Q., & Li, Y. (2025) · ISA transactions · doi:10.1016/j.isatra.2025.12.043 · Cited by 2
Self-citationUrrea, C., & Sari, P. (2025) · Symmetry · doi:10.3390/sym17040591 · Cited by 3 · see citing works
Wang, C.-J., Cheng, B., Tang, Q., Wu, R.-Y., & Li, H.-Y. (2025) · Micromachines · doi:10.3390/mi16121364 · Cited by 1
Liu, K.-P., Wang, C., Wu, X.-L., Sun, Z.-B., Jin, L., & Zhang, J.-L. (2026) · Control Engineering Practice · doi:10.1016/j.conengprac.2026.107031 · Cited by 1
Ma, J.-J., Li, Z.-Q., Yang, Y., Liu, X., & Huang, D.-Q. (2026) · Measurement and control (London. 1968) · doi:10.1177/00202940261500805
Self-citationRosales-Luengas, Y., Salazar, S., Rangel-Popoca, S. J., Cortés-García, Y., & Lozano, R. (2026) · Electronics · doi:10.3390/electronics15173992
T, A., Garg, K., & Joshi, D. (2026) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2025.117411
Sharma, R., Verma, R., & Narayan, J. (2026) · 2026 International Conference on Intelligent Processing, Hardware, Electronics, and Radio Systems (CIPHER) · doi:10.1109/cipher70417.2026.11523833
- Authors
- Yang, Y., Huang, D., Ma, L., Liu, X., & Li, Y.
- Affiliations
- Xihua University (CN)
- Southwest Jiaotong University (CN)
- University of Sussex (GB)
- Corresponding author
- Li, Yanan
- Venue
- ISA Transactions
- Publisher
- Elsevier BV
- Published
- 2024-08
- Volume
- 151
- Pages
- 143-152
- ISSN
- 0019-0578 (ISSN-L)
- OpenAlex
- W4399335187
- Cited by
- 10
- References
- 0
- Citations by year
- 2026: 4 · 2025: 6
- FWCI
- 1.56
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- ISA Transactions (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Natural Science Foundation of Sichuan Province (2023NSFSC1431)
- Sichuan Province Department of Science and Technology
- National Natural Science Foundation of China (62003278, 61973257)
- Topics
- Physical Sciences › Engineering › Control and Systems Engineering › Adaptive Control of Nonlinear Systems
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Physical Sciences › Engineering › Control and Systems Engineering › Iterative Learning Control Systems
- Keywords
- rehabilitation exoskeleton, lower limb rehabilitation, passive training, fault-tolerant control, prescribed performance control, adaptive neural networks, actuator faults, unmodeled dynamics, friction compensation, disturbance compensation, backstepping control, explosion of complexity, nonlinear observer, velocity estimation, output feedback control, state feedback control, Lyapunov stability
- MeSH terms
- Exoskeleton Device, Algorithms, Computer Simulation, Equipment Design, Feedback, Humans, Neural Networks, Computer, Nonlinear Dynamics, Lower Extremity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review