The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Printable Metal-Polymer Conductors for Highly Stretchable Bio-Devices
Open accessAbstract
Stretchable, biocompatible devices can bridge electronics and biology. However, most stretchable conductors for such devices are toxic, costly, and regularly break/degrade after several large deformations. Here we show printable, highly stretchable, and biocompatible metal-polymer conductors by casting and peeling off polymers from patterned liquid metal particles, forming surface-embedded metal in polymeric hosts. Our printable conductors present good stretchability (2,316 S/cm at a strain of 500%) and repeatability (ΔR/R <3% after 10,000 cycles), which can satisfy most electrical applications in extreme deformations. This strategy not only overcomes large surface tension of liquid metal but also avoids the undesirable sintering of its particles by stress in deformations, such that stretchable conductors can form on various substrates with high resolution (15 μm), high throughput (∼2,000 samples/hour), and low cost (one-quarter price of silver). We use these conductors for stretchable circuits, motion sensors, wearable glove keyboards, and electroporation of live cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kim, D.-H., Lu, N., Ma, R., Kim, Y.-S., Kim, R.-H., Wang, S., Wu, J., Won, S. M., Tao, H., Islam, A., et al. (2011) · Science · doi:10.1126/science.1206157 · Cited by 4,836
Bioresorbable silicon electronic sensors for the brain
Kang, S.-K., Murphy, R. K. J., Hwang, S.-W., Lee, S. M., Harburg, D. V., Krueger, N. A., Shin, J., Gamble, P., Cheng, H., Yu, S., et al. (2016) · Nature · doi:10.1038/nature16492 · Cited by 998
Cited by
Attributes, Fabrication, and Applications of Gallium‐Based Liquid Metal Particles
Lin, Y., Genzer, J., & Dickey, M. D. (2020) · Advanced Science · doi:10.1002/advs.202000192 · Cited by 503
Shaping a Soft Future: Patterning Liquid Metals
Ma, J., Krisnadi, F., Vong, M. H., Kong, M., Awartani, O. M., & Dickey, M. D. (2023) · Advanced Materials · doi:10.1002/adma.202205196 · Cited by 311
Guo, R., Sun, X., Yuan, B., Wang, H., & Liu, J. (2019) · Advanced Science · doi:10.1002/advs.201901478 · Cited by 260
Multilayered electronic transfer tattoo that can enable the crease amplification effect
Tang, L., Shang, J., & Jiang, X. (2021) · Science Advances · doi:10.1126/sciadv.abe3778 · Cited by 231
Self-citationEngineering the Comfort‐of‐Wear for Next Generation Wearables
Shimura, T., Sato, S., Zalar, P., & Matsuhisa, N. (2023) · Advanced Electronic Materials · doi:10.1002/aelm.202200512 · Cited by 86
Metadata
- Authors
- Tang, L., Cheng, S., Zhang, L., Mi, H., Mou, L., Yang, S., Huang, Z., Shi, X., & Jiang, X.
- Venue
- iScience
- Publisher
- Elsevier BV
- Published
- 2018-06
- Volume
- 4
- Pages
- 302-311
- ISSN
- 2589-0042 (ISSN-L)
- OpenAlex
- W2808051100
- Cited by
- 164
- References
- 2
- FWCI
- 6.87
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Printable Metal-Polymer Conductors for Highly Stretchable Bio-Devices. https://app.cochat.ai/papers/10.1016/j.isci.2018.05.013
- The paper
- Tang, L., Cheng, S., Zhang, L., Mi, H., Mou, L., Yang, S., Huang, Z., Shi, X., & Jiang, X. (2018). Printable Metal-Polymer Conductors for Highly Stretchable Bio-Devices. iScience. https://doi.org/10.1016/j.isci.2018.05.013
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.